IAdsRpcInvoke.TryInvokeRpcMethod(String, String, Object[], AnyTypeSpecifier[], AnyTypeSpecifier, Object[], Object) Method

Invokes the rpc method.


Namespace: TwinCAT.Ads
Assembly: TwinCAT.Ads.Abstractions (in TwinCAT.Ads.Abstractions.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

AdsErrorCode TryInvokeRpcMethod(
string symbolPath,
string methodName,
Object[]? inParameters,
AnyTypeSpecifier[]? outSpecifiers,
AnyTypeSpecifier? retSpecifier,
out Object[]? outParameters,
out Object?? retValue
)

Parameters

symbolPath  String

The symbol.

methodName  String

Name of the method.

inParameters  Object[]

The parameters.

outSpecifiers  AnyTypeSpecifier[]

The out specifiers (specifying the out types) or NULL.

retSpecifier  AnyTypeSpecifier

The ret specifier (specifying the return value) or NULL.

outParameters  Object[]

The out parameters.

retValue  Object

The return value of the RPC method./>

Return Value

AdsErrorCode
AdsErrorCode.

Remarks

The RpcMethod optionally support In-Parameters, Out-Parameters and Return values. Therefore the parameters inParameters, outParameters, outSpecifiers, retSpecifier are allowed to be empty or NULL. In case of using primitive datatypes, the type specifier parameters (outSpecifiers and retSpecifier) are not necessary and should not be set.

Example

The following sample shows how to call (Remote Procedures / Methods) within the PLC.

Dynamic Tree Mode

class RpcCallVirtualProgram
{
    /// <summary>
    /// Defines the entry point of the application.
    /// </summary>
    /// <param name="args">The arguments.</param>
    static void Main(string[] args)
    {
    // Get the AdsAddress from command-line arguments
    AmsAddress address = ArgParser.Parse(args);

    using (AdsClient client = new AdsClient())
    {
        //client.Synchronize = false;

        // Connect to the target device
        client.Connect(address);

        SymbolLoaderSettings settings = new SymbolLoaderSettings(SymbolsLoadMode.VirtualTree);
        ISymbolLoader loader = SymbolLoaderFactory.Create(client, settings);

        // Get the Symbols (Dynamic Symbols)

        IStructInstance main = (IStructInstance)loader.Symbols["MAIN"]; // Gets the MAIN Instance of the PLC Program

        // Call a Method that has the following signature (within MAIN Program)
        /*  {attribute 'TcRpcEnable'}
        METHOD PUBLIC M_Add : INT
        VAR_INPUT
            i1 : INT := 0;
            i2 : INT := 0;
        END_VAR 
        */

        short result = (short)main.InvokeRpcMethod("M_Add", new object[] {(short) 3, (short) 4});

        // Call a Method that has no parameter and returns VOID
        main.InvokeRpcMethod("M_Method1", new object[] {});

        //Browsing RpcMethods
        foreach(IRpcMethod method in main.RpcMethods)
        {
        string methodName = method.Name;

        foreach(IRpcMethodParameter parameter in method.Parameters)
        {
            string parameterName = parameter.Name;
            string parameterType = parameter.TypeName;
        }
        }
    }
    }
}

See Also

Reference

IAdsRpcInvoke Interface TryInvokeRpcMethod Overload TwinCAT.Ads Namespace

Beckhoff Automation GmbH & Co. KG 2001-2026