AdsConnection.TryInvokeRpcMethod(String, String, Object[], Object) Method

Invokes the specified RPC Method


Namespace: TwinCAT.Ads
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public AdsErrorCode TryInvokeRpcMethod(
string symbolPath,
string methodName,
Object[]? inParameters,
out Object?? retValue
)

Parameters

symbolPath  String

The symbol path.

methodName  String

The method name.

inParameters  Object[]

The parameters.

retValue  Object

The return value of the RPC method as object.

Return Value

AdsErrorCode
The ADS Error Code.

Implements

IAdsRpcInvoke.TryInvokeRpcMethod(String, String, Object[], Object)

Remarks

Because this overload doesn't provide any AnyTypeSpecifier specifications, only primitive datatypes will be correctly marshalled by this method. Complex types will fall back to byte[] arrays.

Example

The following sample shows how to call (Remote Procedures / Methods) within the PLC.

Dynamic Tree Mode

class RpcCallVirtualProgram
{
    /// <summary>
    /// Defines the entry point of the application.
    /// </summary>
    /// <param name="args">The arguments.</param>
    static void Main(string[] args)
    {
    // Get the AdsAddress from command-line arguments
    AmsAddress address = ArgParser.Parse(args);

    using (AdsClient client = new AdsClient())
    {
        //client.Synchronize = false;

        // Connect to the target device
        client.Connect(address);

        SymbolLoaderSettings settings = new SymbolLoaderSettings(SymbolsLoadMode.VirtualTree);
        ISymbolLoader loader = SymbolLoaderFactory.Create(client, settings);

        // Get the Symbols (Dynamic Symbols)

        IStructInstance main = (IStructInstance)loader.Symbols["MAIN"]; // Gets the MAIN Instance of the PLC Program

        // Call a Method that has the following signature (within MAIN Program)
        /*  {attribute 'TcRpcEnable'}
        METHOD PUBLIC M_Add : INT
        VAR_INPUT
            i1 : INT := 0;
            i2 : INT := 0;
        END_VAR 
        */

        short result = (short)main.InvokeRpcMethod("M_Add", new object[] {(short) 3, (short) 4});

        // Call a Method that has no parameter and returns VOID
        main.InvokeRpcMethod("M_Method1", new object[] {});

        //Browsing RpcMethods
        foreach(IRpcMethod method in main.RpcMethods)
        {
        string methodName = method.Name;

        foreach(IRpcMethodParameter parameter in method.Parameters)
        {
            string parameterName = parameter.Name;
            string parameterType = parameter.TypeName;
        }
        }
    }
    }
}

See Also

Reference

AdsConnection Class TryInvokeRpcMethod Overload TwinCAT.Ads Namespace

Beckhoff Automation GmbH & Co. KG 2001-2026