AdsClient.TryAddDeviceNotification(UInt32, UInt32, Int32, NotificationSettings, Object, UInt32) Method

Connects a variable to the ADS client. The ADS client will be notified by the AdsNotification event.


Namespace: TwinCAT.Ads
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public AdsErrorCode TryAddDeviceNotification(
uint indexGroup,
uint indexOffset,
int dataSize,
NotificationSettings settings,
Object? userData,
out uint handle
)

Parameters

indexGroup  UInt32

The index group number of the requested ADS service.

indexOffset  UInt32

The index offset number of the requested ADS service.

dataSize  Int32

Maximum amount of data in bytes to receive with this ADS Notification.

settings  NotificationSettings

The Notification settings.

userData  Object

This object can be used to store user specific data (tag data)

handle  UInt32

The notification handle.

Return Value

AdsErrorCode
The ADS error code.

Implements

IAdsNotifications.TryAddDeviceNotification(UInt32, UInt32, Int32, NotificationSettings, Object, UInt32)

Exceptions

Exception

Condition

ObjectDisposedException

ClientNotConnectedException

Remarks

The

dataSize

Parameter defines the amount of bytes, that will be attached to the AdsNotification as value. Because notifications allocate TwinCAT system resources, a complementary call to TryDeleteDeviceNotification(UInt32) should always called when the notification is not used anymore.

See Also

Reference

AdsClient Class TryAddDeviceNotification Overload TwinCAT.Ads Namespace TryDeleteDeviceNotification(UInt32) AdsNotification AdsNotificationError {0} Overload {0} Overload {0} Overload