IRpcStructType Interface
Note: This API is now obsolete.
Interface IRpcStructType Implements the IRpcCallableType Implements the IStructType
          Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads.Abstractions (in
TwinCAT.Ads.Abstractions.dll) Version: 6.0.328+39e3229
Syntax
C#
[ObsoleteAttribute("Use IStructType instead")]
public interface IRpcStructType : IRpcCallableType, 
    IStructType, IInterfaceType, IDataType, IBitSizeThe IRpcStructType type exposes the following members.
Properties
| 
 | Name | Description | 
|---|---|---|
| 
 | Gets all members (down the derivation hierarchy) (Inherited from IInterfaceType.) | |
| 
 | Gets the attributes of the IDataType (Inherited from IDataType.) | |
| 
 | Gets the structs Base Type (Null if not derived). (Inherited from IInterfaceType.) | |
| 
 | Gets the the Name of the Base class (if derived) (Inherited from IInterfaceType.) | |
| 
 | Gets the size of the IDataType in bits. (Inherited from IBitSize.) | |
| 
 | Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.) | |
| 
 | Gets the Data Type category (Inherited from IDataType.) | |
| 
 | Gets the comment behind the variable declaration. (Inherited from IDataType.) | |
| 
 | Gets the full name of the IDataType (Namespace + Name) (Inherited from IDataType.) | |
| 
 | Gets a value indicating whether this instance has RPC methods (Struct types only) (Inherited from IInterfaceType.) | |
| 
 | Gets the ID of the DataType (Inherited from IDataType.) | |
| 
 | Gets the names of the interfaces, this IDataType implements. (Inherited from IInterfaceType.) | |
| 
 | Gets the resolved interface types, this IDataType implements. (Inherited from IInterfaceType.) | |
| 
 | Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.) | |
| 
 | Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.) | |
| 
 | Gets a readonly collection of the Members of the IInterfaceType. (Inherited from IInterfaceType.) | |
| 
 | Gets the name of the Data Type (without namespace) (Inherited from IDataType.) | |
| 
 | Gets the namespace string within the IDataType exists. (Inherited from IDataType.) | |
| 
 | Gets the Method descriptions for the IRpcCallableType (Inherited from IRpcCallableType.) | |
| 
 | Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.) | 
Extension Methods
| 
 | Name | Description | 
|---|---|---|
| 
 | Overloaded. Determines whether the dataType is an array of Primitives. (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Determines whether the dataType is an array of Primitives. (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Gets a value indicating whether this IDataType is a container type (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Gets a value indicating whether this IDataType is a container type (Defined by DataTypeExtension.) | |
| 
 | Gets a value indicating whether this IDataType is a pointer type (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Gets a value indicating whether this IDataType is primitive (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Gets a value indicating whether this IDataType is primitive (Defined by DataTypeExtension.) | |
| 
 | Gets a value indicating whether this IDataType is a reference type (Defined by DataTypeExtension.) | |
| 
 | Indicates, that the Instance value includes process memory data, that cannot be read in one memory block. (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Indicates, that this data type can be resolved as primitive or primmitive Array. (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Indicates, that this data type can be resolved as primitive or primmitive Array. (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Resolves the specified data type for AliasReference (Defined by DataTypeExtension.) | |
| 
 | Overloaded. Resolves the specified strategy. (Defined by DataTypeExtension.) |