IInterfaceType Interface
Interface representing an Interface Data type. Implements the IDataType
Namespace: TwinCAT.TypeSystem
Assembly: TwinCAT.Ads.Abstractions (in TwinCAT.Ads.Abstractions.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470
Syntax
C#
public interface IInterfaceType : IDataType,
IBitSize, IRpcCallableTypeThe IInterfaceType type exposes the following members.
Properties
|
|
Name |
Description |
|---|---|---|
|
|
Gets all members (down the derivation hierarchy) | |
|
|
Gets the attributes of the IDataType | |
|
|
Gets the structs Base Type (Null if not derived). | |
|
|
Gets the the Name of the Base class (if derived) | |
|
|
Gets the size of the IDataType in bits.
| |
|
|
Gets the (aligned) size of of the Type/Instance in Bytes
| |
|
|
Gets the Data Type category
| |
|
|
Gets the comment behind the variable declaration.
| |
|
|
Gets the full name of the IDataType (Namespace + Name)
| |
|
|
Gets a value indicating whether this instance has RPC methods (Struct types only) | |
|
|
Gets the ID of the DataType
| |
|
|
Gets the names of the interfaces, this IDataType implements. | |
|
|
Gets the resolved interface types, this IDataType implements. | |
|
|
Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping
| |
|
|
Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0)
| |
|
|
Gets a readonly collection of the Members of the IInterfaceType. | |
|
|
Gets the name of the Data Type (without namespace)
| |
|
|
Gets the namespace string within the IDataType exists.
| |
|
|
Gets the Method descriptions for the IRpcCallableType | |
|
|
Gets the size of the object in bytes or Bits dependant on IsBitType |
Extension Methods
|
|
Name |
Description |
|---|---|---|
|
|
Indicates, that the Instance value includes process memory data, that cannot be read in one memory block.
| |
|
|
Determines whether the dataType is an array of Primitives.
| |
|
|
Determines whether the dataType is an array of Primitives.
| |
|
|
Gets a value indicating whether this IDataType is a container type
| |
|
|
Gets a value indicating whether this IDataType is a container type
| |
|
|
Gets a value indicating whether this IDataType is a pointer type
| |
|
|
Gets a value indicating whether this IDataType is primitive
| |
|
|
Gets a value indicating whether this IDataType is primitive
| |
|
|
Gets a value indicating whether this IDataType is a reference type
| |
|
|
Indicates, that this data type can be resolved as primitive or primmitive Array.
| |
|
|
Indicates, that this data type can be resolved as primitive or primmitive Array.
| |
|
|
Resolves the specified data type for AliasReference (Resolving the IAliasType/IReferenceType)
| |
|
|
Resolves the specified strategy.
|