Technical data
All values are typical values over the entire temperature range, unless stated otherwise.
| Supply voltages | |
|---|---|
| Connection | See EtherCAT P connection | 
| US nominal voltage | 24 VDC (-15 % / +20 %) | 
| US sum current: IS,sum | max. 3 A | 
| Current consumption from US | 100 mA + current consumption of the encoder | 
| UP nominal voltage | 24 VDC (-15 % / +20 %) | 
| UP sum current: IP,sum | max. 3 A | 
| Current consumption from UP | None. UP is only forwarded. | 
| Electrical isolation | GNDS, GNDP and "GND Motor" are electrically isolated from each other. | 
| Motor channels | |
|---|---|
| Number | 2 | 
| Motor type | DC brush motor, inductive | 
| Connection | 1x M12 common socket for both motors | 
| Cable length | max. 30 m | 
| Motor supply | 8 … 48 VDC | 
| Motor supply connection | 1 x M12 socket | 
| Nominal current per channel | 3.5 A, short-circuit proof | 
| Overload protection | Thermal overload warning | 
| Resolution | Current: max. 10 bit | 
| PWM clock frequency | 30 kHz with 180° phase shift each | 
| PWM duty cycle | 0 ... 100% (voltage-controlled) | 
| Current controller frequency | approx. 25 kHz | 
| Encoder inputs | |
|---|---|
| Number | 2 | 
| Encoder type | Incremental encoders | 
| Connection | 1x M12 socket per encoder | 
| Encoder supply | 24 VDC from peripheral voltage US, not short-circuit proof | 
| Signals | Single-ended | 
| Signal voltage "0" | -3 … 1.5 V | 
| Signal voltage "1" | 2.5 … 24 V | 
| Pulse frequency | max. 400,000 increments per second with 4-fold evaluation | 
| Housing data | |
|---|---|
| Dimensions W x H x D | 30 mm x 126 mm x 26.5 mm (without connectors) | 
| Weight | approx. 165 g | 
| Installation position | variable | 
| Material | PA6 (polyamide) | 
| Environmental conditions | |
|---|---|
| Ambient temperature during operation | -25 … +60 °C | 
| Ambient temperature during storage | -40 … +85 °C | 
| Vibration / shock resistance | conforms to EN 60068-2-6 / EN 60068-2-27 | 
| EMC immunity / emission | conforms to EN 61000-6-2 / EN 61000-6-4 | 
| Protection class | IP65, IP66, IP67 conforms to EN 60529 | 
| Approvals / markings | |
|---|---|
| Approvals / markings *) | CE, UL under preparation | 
*) Real applicable approvals/markings see type plate on the side (product marking).
Additional tests
The devices have undergone the following additional tests:
| Test | Explanation | 
|---|---|
| Vibration | 10 frequency sweeps in 3 axes | 
| 5 Hz < f < 60 Hz displacement 0.35 mm, constant amplitude | |
| 60.1 Hz < f < 500 Hz acceleration 5 g, constant amplitude | |
| Shocks | 1000 shocks in each direction, in 3 axes | 
| 35 g, 11 ms |