Object overview
![]()  | IO-Link IODD Device Description The display corresponds to the display of the IO-Link device parameters. It is advisable to download the latest IO-Link IODD device description files from the Download section of the Beckhoff website and install them according to the installation instructions.  | 
The following example shows the object overview of EPI4374-0002 as an example.
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0000:0  | Direct Parameters 1  | RO  | 16  | 
0x0000:01  | Reserved  | RO  | 0  | 
0x0000:02  | Master Cycle Time  | RO  | 0  | 
0x0000:03  | Min Cycle Time  | RO  | 0  | 
0x0000:04  | M-Sequence Capability  | RO  | 0  | 
0x0000:05  | IO-Link Version ID  | RO  | 0  | 
0x0000:06  | Process Data Input Length  | RO  | 0  | 
0x0000:07  | Process Data Output Length  | RO  | 0  | 
0x0000:08  | Vendor ID 1  | RO  | 0  | 
0x0000:09  | Vendor ID 2  | RO  | 0  | 
0x0000:0A  | Device ID 1  | RO  | 0  | 
0x0000:0B  | Device ID 2  | RO  | 0  | 
0x0000:0C  | Device ID 3  | RO  | 0  | 
0x0000:0D  | Reserved  | RO  | 0  | 
0x0000:0E  | Reserved  | RO  | 0  | 
0x0000:0F  | Reserved  | RO  | 0  | 
0x0000:10  | System Command  | RO  | 0  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0001:0  | Direct Parameters 2  | RW  | 16  | 
0x0001:01  | Device Specific Parameter 1  | RW  | 0  | 
0x0001:02  | Device Specific Parameter 2  | RW  | 0  | 
0x0001:03  | Device Specific Parameter 3  | RW  | 0  | 
0x0001:04  | Device Specific Parameter 4  | RW  | 0  | 
0x0001:05  | Device Specific Parameter 5  | RW  | 0  | 
0x0001:06  | Device Specific Parameter 6  | RW  | 0  | 
0x0001:07  | Device Specific Parameter 7  | RW  | 0  | 
0x0001:08  | Device Specific Parameter 8  | RW  | 0  | 
0x0001:09  | Device Specific Parameter 9  | RW  | 0  | 
0x0001:0A  | Device Specific Parameter 10  | RW  | 0  | 
0x0001:0B  | Device Specific Parameter 11  | RW  | 0  | 
0x0001:0C  | Device Specific Parameter 12  | RW  | 0  | 
0x0001:0D  | Device Specific Parameter 13  | RW  | 0  | 
0x0001:0E  | Device Specific Parameter 14  | RW  | 0  | 
0x0001:0F  | Device Specific Parameter 15  | RW  | 0  | 
0x0001:10  | Device Specific Parameter 16  | RW  | 0  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0002  | Standard Command  | WO  | 0  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x000C:0  | Device Access Locks  | RW  | 2  | 
0x000C:01  | Parameter (write) Access Lock  | RW  | 0  | 
0x000C:02  | Data Storage Lock  | RW  | 0  | 
0x000C:03  | Local Parameterization Lock  | RW  | 0  | 
0x000C:04  | Local User Interface Lock  | RW  | 0  | 
Index  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0010  | Vendor Name  | RO  | Beckhoff Automation GmbH & Co. KG  | 
0x0011  | Vendor Text  | RO  | www.beckhoff.com  | 
0x0012  | Product Name  | RO  | EPI4374-0002  | 
0x0013  | Product ID  | RO  | EPI4374-0002  | 
0x0014  | Product Text  | RO  | 2 analog input 2 analog output modules  | 
0x0015  | Serial Number  | RO  | 00000000  | 
0x0016  | Hardware version  | RO  | 00  | 
0x0017  | Firmware version  | RO  | 00  | 
0x0018  | Application-Specific Tag  | RW  | 0  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0050:0  | IO Status  | RO  | 4  | 
0x0050:01  | State  | RO  | 0x0000 (0dec)  | 
0x0500:02  | Status code  | RO  | 0x0000 (0dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0800:0  | AI Settings Ch 1  | RW  | 18  | 
0x0800:01  | Enable User Scale  | RW  | 0x00 (0dec)  | 
0x0800:02  | Presentation  | RW  | Signed  | 
0x0800:05  | Siemens bits  | RW  | 0x00 (0dec)  | 
0x0800:06  | Enable filter  | RW  | 0x01 (1dec)  | 
0x0800:07  | Enable Limit 1  | RW  | 0x00 (0dec)  | 
0x0800:08  | Enable Limit 2  | RW  | 0x00 (0dec)  | 
0x0800:0A  | Enable User Calibration  | RW  | 0x00 (0dec)  | 
0x0800:0B  | Enable Vendor Calibration  | RW  | 0x01 (1dec)  | 
0x0800:0E  | Swap Limit Bits  | RW  | 0x00 (0dec)  | 
0x0800:11  | User Scale Offset  | RW  | 0x0000 (0dec)  | 
0x0800:12  | User Scale Gain  | RW  | 0x00010000 (65536dec)  | 
0x0800:13  | Limit 1  | RW  | 0x0000 (0dec)  | 
0x0800:14  | Limit 2  | RW  | 0x0000 (0dec)  | 
0x0800:15  | Filter Settings  | RW  | 50 Hz FIR  | 
0x0800:17  | User Calibration Offset  | RW  | 0x0000 (0dec)  | 
0x0800:18  | User Calibration Gain  | RW  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x080E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x080F:0  | AI Vendor Data Ch 1  | RO  | 12  | 
0x080F:01  | R0 Offset  | RO  | 0x0000 (0dec)  | 
0x080F:02  | R0 Gain  | RO  | 0x4000 (16384dec)  | 
0x080F:03  | R1 Offset  | RO  | 0x0000 (0dec)  | 
0x080F:04  | R1 Gain  | RO  | 0x4000 (16384dec)  | 
0x080F:05  | R2 Offset  | RO  | 0x0000 (0dec)  | 
0x080F:06  | R2 Gain  | RO  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0810:0  | AI Settings Ch 2  | RW  | 18  | 
0x0810:01  | Enable User Scale  | RW  | 0x00 (0dec)  | 
0x0810:02  | Presentation  | RW  | Signed  | 
0x0810:05  | Siemens bits  | RW  | 0x00 (0dec)  | 
0x0810:07  | Enable Limit 1  | RW  | 0x00 (0dec)  | 
0x0810:08  | Enable Limit 2  | RW  | 0x00 (0dec)  | 
0x0810:0A  | Enable User Calibration  | RW  | 0x00 (0dec)  | 
0x0810:0B  | Enable Vendor Calibration  | RW  | 0x01 (1dec)  | 
0x0810:0E  | Swap Limit Bits  | RW  | 0x00 (0dec)  | 
0x0810:11  | User Scale Offset  | RW  | 0x0000 (0dec)  | 
0x0810:12  | User Scale Gain  | RW  | 0x00010000 (65536dec)  | 
0x0810:13  | Limit 1  | RW  | 0x0000 (0dec)  | 
0x0810:14  | Limit 2  | RW  | 0x0000 (0dec)  | 
0x0810:17  | User Calibration Offset  | RW  | 0x0000 (0dec)  | 
0x0810:18  | User Calibration Gain  | RW  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x081E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x081F:0  | AI Vendor Data Ch. 2  | RO  | 12  | 
0x081F:01  | R0 Offset  | RO  | 0x0000 (0dec)  | 
0x081F:02  | R0 Gain  | RO  | 0x4000 (16384dec)  | 
0x081F:03  | R1 Offset  | RO  | 0x0000 (0dec)  | 
0x081F:04  | R1 Gain  | RO  | 0x4000 (16384dec)  | 
0x081F:05  | R2 Offset  | RO  | 0x0000 (0dec)  | 
0x081F:06  | R2 Gain  | RO  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0820:0  | AO Settings Ch. 3  | RW  | 16  | 
0x0820:01  | Enable User Scale  | RW  | 0x00 (0dec)  | 
0x0820:02  | Presentation  | RW  | Signed  | 
0x0820:05  | Watchdog  | RW  | 0x00 (0dec)  | 
0x0820:07  | Enable User Calibration  | RW  | 0x00 (0dec)  | 
0x0820:08  | Enable Vendor Calibration  | RW  | 0x00 (0dec)  | 
0x0820:11  | User Scale Offset  | RW  | 0x0000 (0dec)  | 
0x0820:12  | User Scale Gain  | RW  | 0x00010000 (65536dec)  | 
0x0820:13  | Default output  | RW  | 0x0000 (0dec)  | 
0x0820:14  | Default output ramp  | RW  | 0xFFFF (65535dec)  | 
0x0820:15  | User Calibration Offset  | RW  | 0x0000 (0dec)  | 
0x0820:16  | User Calibration Gain  | RW  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x082E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x082F:0  | OI Vendor Data Ch 3  | RO  | 12  | 
0x082F:01  | R0 Offset  | RO  | 0x0000 (0dec)  | 
0x082F:02  | R0 Gain  | RO  | 0x4000 (16384dec)  | 
0x082F:03  | R1 Offset  | RO  | 0x0000 (0dec)  | 
0x082F:04  | R1 Gain  | RO  | 0x4000 (16384dec)  | 
0x082F:05  | R2 Offset  | RO  | 0x0000 (0dec)  | 
0x082F:06  | R2 Gain  | RO  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0830:0  | AO Settings Ch 4  | RW  | 18  | 
0x0830:01  | Enable User Scale  | RW  | 0x00 (0dec)  | 
0x0830:02  | Presentation  | RW  | Signed  | 
0x0830:05  | Watchdog  | RW  | 0x00 (0dec)  | 
0x0830:07  | Enable User Calibration  | RW  | 0x00 (0dec)  | 
0x0830:08  | Enable Vendor Calibration  | RW  | 0x00 (0dec)  | 
0x0830:11  | User Scale Offset  | RW  | 0x0000 (0dec)  | 
0x0830:12  | User Scale Gain  | RW  | 0x00010000 (65536dec)  | 
0x0830:13  | Default output  | RW  | 0x0000 (0dec)  | 
0x0830:14  | Default output ramp  | RW  | 0xFFFF (65535dec)  | 
0x0830:15  | User Calibration Offset  | RW  | 0x0000 (0dec)  | 
0x0830:16  | User Calibration Gain  | RW  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x083E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x083F:0  | AI Vendor Data Ch 4  | RO  | 12  | 
0x083F:01  | R0 Offset  | RO  | 0x0000 (0dec)  | 
0x083F:02  | R0 Gain  | RO  | 0x4000 (16384dec)  | 
0x083F:03  | R1 Offset  | RO  | 0x0000 (0dec)  | 
0x083F:04  | R1 Gain  | RO  | 0x4000 (16384dec)  | 
0x083F:05  | R2 Offset  | RO  | 0x0000 (0dec)  | 
0x083F:06  | R2 Gain  | RO  | 0x4000 (16384dec)  | 
Subindex  | Name  | Flags  | Default value  | 
|---|---|---|---|
0x0A00:0  | Diagnostics  | RO  | 2  | 
0x0A00:01  | Overtemperature  | RO  | 0  | 
0x0A00:02  | Short detected  | RO  | 0  | 
0x0A00:03  | L+ low  | RO  | 0  | 
0x0A00:04  | 2L+ low 1)  | RO  | 0  | 
0x0A00:05  | 2L+ stat 1)  | RO  | 0  | 
0x0A00:06  | Reserved  | RO  | 0  | 
0x0A00:07  | Reserved  | RO  | 0  | 
0x0A00:08  | Reserved  | RO  | 0  | 
0x0A00:09  | Reserved  | RO  | 0  | 
0x0A00:0A  | Reserved  | RO  | 0  | 
0x0A00:0B  | Reserved  | RO  | 0  | 
0x0A00:0C  | Reserved  | RO  | 0  | 
0x0A00:0D  | Reserved  | RO  | 0  | 
0x0A00:0E  | Reserved  | RO  | 0  | 
0x0A00:0E  | Reserved  | RO  | 0  | 
0x0A00:10  | Reserved  | RO  | 0  | 
1) „2L+“ was the original name for „P24” in the IO-Link specification
Subindex  | Name  | Flags  | Default value  | |
|---|---|---|---|---|
0x3800:0  | AI Range Settings  | RW  | 10  | |
0x3800:01  | Input type Ch1  | 0 dec: -10 V…+10 V  | RW  | 0x0000 (0dec)  | 
0x3800:02  | Input type Ch2  | RW  | 0x0000 (0dec)  | |
0x3800:03  | Input type Ch3  | RW  | 0x0000 (0dec)  | |
0x3800:04  | Input type Ch4  | RW  | 0x0000 (0dec)  | |
Key
Flags:
- RO (Read Only): this object can only be read.
 - RW (Read/Write): this object can be read or written.
 