Objects for information and diagnostics
Index 800F: BCT Vendor data
Index  | Name  | Meaning  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
800F:0  | BCT Vendor data  | 
  | UINT8  | RO  | 0x16 (22dec)  | 
800F:13  | Resistor current offset  | Vendor calibration: Offset value for current measurement.  | INT16  | RW  | -  | 
800F:14  | Resistor current gain  | Vendor calibration: Gain value for current measurement.  | UINT16  | RW  | -  | 
800F:15  | DC link voltage offset  | Vendor calibration: Offset value for voltage measurement.  | INT16  | RW  | -  | 
800F:16  | DC link voltage gain  | Vendor calibration: Offset value for voltage measurement.  | UINT16  | RW  | -  | 
Index A000: BCT Diag data
Index  | Name  | Description  | Data type  | Flags  | Default  | 
|---|---|---|---|---|---|
A000:0  | BCT Diag data  | 
  | UINT8  | RO  | 0x11 (17dec)  | 
A000:11  | Temperature  | Internal temperature. Unit: °C.  | UINT8  | RO  | -  |