Standard objects
Index 1000 Device type (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1000:0 | Device type | Device type of the EtherCAT slave: the Lo-Word contains the used CoE profile (5001). The Hi-Word contains the module profile according to the modular device profile. | UINT32 | RO | 0x10e1389 (17699721dec) |
Index 1000 Device type (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1000:0 | Device type | Device type of the EtherCAT slave: the Lo-Word contains the used CoE profile (5001). The Hi-Word contains the module profile according to the modular device profile. | UINT32 | RO | 0x00001389 (5001dec) |
Index 1008 Device name
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1008:0 | Device name | Device name of the EtherCAT slave | STRING | RO | EP9214-0023 / EP9224-0023 / EP9214-0024 / EP9224-0024 |
Index 1009 Hardware version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1009:0 | Hardware version | Hardware version of the EtherCAT slave | STRING | RO |
|
Index 100A Software version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
100A:0 | Software version | Firmware version of the EtherCAT slave | STRING | RO | 07 |
100B Bootloader version
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
100B:0 | Bootloader version | - | STRING | RO | - |
Index 1018 Identity (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1018:0 | Identity | Information for identifying the slave | UINT8 | RO | 0x04 (4dec) |
1018:01 | Vendor ID | Vendor ID of the EtherCAT slave | UINT32 | RO | 0x00000002 (2dec) |
1018:02 | Product code | Product code of the EtherCAT slave | UINT32 | RO | 0x23FE4052 (603865170dec) |
1018:03 | Revision | Revision number of the EtherCAT slave; the Low Word (bit 0-15) indicates the special terminal number, the High Word (bit 16-31) refers to the device description | UINT32 | RO | 0x00000000 (0dec) |
1018:04 | Serial number | Serial number of the EtherCAT slave; the Low Byte (bit 0-7) of the Low Word contains the year of production, the High Byte (bit 8-15) of the Low Word contains the week of production, the High Word (bit 16-31) is 0 | UINT32 | RO | 0x00000000 (0dec) |
Index 1018 Identity (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1018:0 | Identity | Information for identifying the slave | UINT8 | RO | 0x04 (4dec) |
1018:01 | Vendor ID | Vendor ID of the EtherCAT slave | UINT32 | RO | 0x00000002 (2dec) |
1018:02 | Product code | Product code of the EtherCAT slave | UINT32 | RO | 0x24084052 (604520530dec) |
1018:03 | Revision | Revision number of the EtherCAT slave; the Low Word (bit 0-15) indicates the special terminal number, the High Word (bit 16-31) refers to the device description | UINT32 | RO | 0x00000000 (0dec) |
1018:04 | Serial number | Serial number of the EtherCAT slave; the Low Byte (bit 0-7) of the Low Word contains the year of production, the High Byte (bit 8-15) of the Low Word contains the week of production, the High Word (bit 16-31) is 0 | UINT32 | RO | 0x00000000 (0dec) |
Index 10F0 Backup parameter handling
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
10F0:01 | Checksum | Checksum across all backup entries of the EtherCAT slave | UINT32 | RO | 0x00000000 (0dec) |
Index 1600 DPO RxPDO-Map Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1600:0 | DPO RxPDO-Map Outputs Ch.1 | PDO Mapping RxPDO 1 | UINT8 | RO | 0x06 (6dec) |
1600:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7000 (DPO Outputs Ch.1), entry 0x01 (Output Us)) | UINT32 | RO | 0x7000:01, 1 |
1600:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7000 (DPO Outputs Ch.1), entry 0x02 (Output Up)) | UINT32 | RO | 0x7000:02, 1 |
1600:03 | SubIndex 003 | 3. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1600:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7000 (DPO Outputs Ch.1), entry 0x05 (Reset Us)) | UINT32 | RO | 0x7000:05, 1 |
1600:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x7000 (DPO Outputs Ch.1), entry 0x06 (Reset Up)) | UINT32 | RO | 0x7000:06, 1 |
1600:06 | SubIndex 006 | 6. PDO Mapping entry (10 bits align) | UINT32 | RO | 0x0000:00, 10 |
1601 DPO RxPDO-Map Outputs Ch.2 (EP9214-0023, EP2914-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1601:0 | DPO RxPDO-Map Outputs Ch.2 |
| USINT | RO | 0x6 (6dec) |
1601:01 | SubIndex 001 |
| UDINT | RO | 0x70100101 (1880097025dec) |
1601:02 | SubIndex 002 |
| UDINT | RO | 0x70100201 (1880097281dec) |
1601:03 | SubIndex 003 |
| UDINT | RO | 0x2 (2dec) |
1601:04 | SubIndex 004 |
| UDINT | RO | 0x70100501 (1880098049dec) |
1601:05 | SubIndex 005 |
| UDINT | RO | 0x70100601 (1880098305dec) |
1601:06 | SubIndex 006 |
| UDINT | RO | 0xa (10dec) |
Index 1601 DPO RxPDO-Map Extended Diag Outputs Ch.1 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1601:0 | DPO RxPDO-Map Extended Diag Outputs Ch.1 | PDO Mapping RxPDO 2 | UINT8 | RO | 0x02 (2dec) |
1601:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7000 (DPO Outputs Ch.1), entry 0x11 (Reset Extended Diag Data)) | UINT32 | RO | 0x7000:11, 1 |
1601:02 | SubIndex 002 | 2. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
1602 DPO RxPDO-Map Outputs Ch.3 (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1602:0 | DPO RxPDO-Map Outputs Ch.3 |
| USINT | RO | 0x6 (6dec) |
1602:01 | SubIndex 001 |
| UDINT | RO | 0x70200101 (1881145601dec) |
1602:02 | SubIndex 002 |
| UDINT | RO | 0x70200201 (1881145857dec) |
1602:03 | SubIndex 003 |
| UDINT | RO | 0x2 (2dec) |
1602:04 | SubIndex 004 |
| UDINT | RO | 0x70200501 (1881146625dec) |
1602:05 | SubIndex 005 |
| UDINT | RO | 0x70200601 (1881146881dec) |
1602:06 | SubIndex 006 |
| UDINT | RO | 0xa (10dec) |
Index 1602 DPO RxPDO-Map Outputs Ch.2 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1602:0 | DPO RxPDO-Map Outputs Ch.2 | PDO Mapping RxPDO 3 | UINT8 | RO | 0x06 (6dec) |
1602:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DPO Outputs Ch.2), entry 0x01 (Output Us)) | UINT32 | RO | 0x7010:01, 1 |
1602:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7010 (DPO Outputs Ch.2), entry 0x02 (Output Up)) | UINT32 | RO | 0x7010:02, 1 |
1602:03 | SubIndex 003 | 3. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1602:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7010 (DPO Outputs Ch.2), entry 0x05 (Reset Us)) | UINT32 | RO | 0x7010:05, 1 |
1602:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x7010 (DPO Outputs Ch.2), entry 0x06 (Reset Up)) | UINT32 | RO | 0x7010:06, 1 |
1602:06 | SubIndex 006 | 6. PDO Mapping entry (10 bits align) | UINT32 | RO | 0x0000:00, 10 |
1603 DPO RxPDO-Map Outputs Ch.4 (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1603:0 | DPO RxPDO-Map Outputs Ch.4 |
| USINT | RO | 0x6 (6dec) |
1603:01 | SubIndex 001 |
| UDINT | RO | 0x70300101 (1882194177dec) |
1603:02 | SubIndex 002 |
| UDINT | RO | 0x70300201 (1882194433dec) |
1603:03 | SubIndex 003 |
| UDINT | RO | 0x2 (2dec) |
1603:04 | SubIndex 004 |
| UDINT | RO | 0x70300501 (1882195201dec) |
1603:05 | SubIndex 005 |
| UDINT | RO | 0x70300601 (1882195457dec) |
1603:06 | SubIndex 006 |
| UDINT | RO | 0xa (10dec) |
Index 1603 DPO RxPDO-Map Extended Diag Outputs Ch.2 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1603:0 | DPO RxPDO-Map Extended Diag Outputs Ch.2 | PDO Mapping RxPDO 4 | UINT8 | RO | 0x02 (2dec) |
1603:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7010 (DPO Outputs Ch.2), entry 0x11 (Reset Extended Diag Data)) | UINT32 | RO | 0x7010:11, 1 |
1603:02 | SubIndex 002 | 2. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
1604 DPO RxPDO-Map Outputs Device (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1604:0 | DPO RxPDO-Map Outputs Device |
| USINT | RO | 0x4 (4dec) |
1604:01 | SubIndex 001 |
| UDINT | RO | 0xf7070101 (4144431361dec) |
1604:02 | SubIndex 002 |
| UDINT | RO | 0x2 (2dec) |
1604:03 | SubIndex 003 |
| UDINT | RO | 0xf7070401 (4144432129dec) |
1604:04 | SubIndex 004 |
| UDINT | RO | 0xc (12dec) |
Index 1604 DPO RxPDO-Map Outputs Ch.3 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1604:0 | DPO RxPDO-Map Outputs Ch.3 | PDO Mapping RxPDO 5 | UINT8 | RO | 0x06 (6dec) |
1604:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7020 (DPO Outputs Ch.3), entry 0x01 (Output Us)) | UINT32 | RO | 0x7020:01, 1 |
1604:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7020 (DPO Outputs Ch.3), entry 0x02 (Output Up)) | UINT32 | RO | 0x7020:02, 1 |
1604:03 | SubIndex 003 | 3. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1604:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7020 (DPO Outputs Ch.3), entry 0x05 (Reset Us)) | UINT32 | RO | 0x7020:05, 1 |
1604:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x7020 (DPO Outputs Ch.3), entry 0x06 (Reset Up)) | UINT32 | RO | 0x7020:06, 1 |
1604:06 | SubIndex 006 | 6. PDO Mapping entry (10 bits align) | UINT32 | RO | 0x0000:00, 10 |
Index 1605 DPO RxPDO-Map Extended Diag Outputs Ch.3 (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1605:0 | DPO RxPDO-Map Extended Diag Outputs Ch.3 | PDO Mapping RxPDO 6 | UINT8 | RO | 0x02 (2dec) |
1605:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7020 (DPO Outputs Ch.3), entry 0x11 (Reset Extended Diag Data)) | UINT32 | RO | 0x7020:11, 1 |
1605:02 | SubIndex 002 | 2. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
Index 1606 DPO RxPDO-Map Outputs Ch.4 (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1606:0 | DPO RxPDO-Map Outputs Ch.4 | PDO Mapping RxPDO 7 | UINT8 | RO | 0x06 (6dec) |
1606:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7030 (DPO Outputs Ch.4), entry 0x01 (Output Us)) | UINT32 | RO | 0x7030:01, 1 |
1606:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7030 (DPO Outputs Ch.4), entry 0x02 (Output Up)) | UINT32 | RO | 0x7030:02, 1 |
1606:03 | SubIndex 003 | 3. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1606:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x7030 (DPO Outputs Ch.4), entry 0x05 (Reset Us)) | UINT32 | RO | 0x7030:05, 1 |
1606:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x7030 (DPO Outputs Ch.4), entry 0x06 (Reset Up)) | UINT32 | RO | 0x7030:06, 1 |
1606:06 | SubIndex 006 | 6. PDO Mapping entry (10 bits align) | UINT32 | RO | 0x0000:00, 10 |
Index 1607 DPO RxPDO-Map Extended Diag Outputs Ch.4 (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1607:0 | DPO RxPDO-Map Extended Diag Outputs Ch.4 | PDO Mapping RxPDO 8 | UINT8 | RO | 0x02 (2dec) |
1607:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7030 (DPO Outputs Ch.4), entry 0x11 (Reset Extended Diag Data)) | UINT32 | RO | 0x7030:11, 1 |
1607:02 | SubIndex 002 | 2. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
Index 1608 DPO RxPDO-Map Outputs Device (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1608:0 | DPO RxPDO-Map Outputs Device | PDO Mapping RxPDO 9 | UINT8 | RO | 0x04 (4dec) |
1608:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF707 (DPO Outputs Device), entry 0x01 (Enable Control Via Fieldbus)) | UINT32 | RO | 0xF707:01, 1 |
1608:02 | SubIndex 002 | 2. PDO Mapping entry (2 bits align) | UINT32 | RO | 0x0000:00, 2 |
1608:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF707 (DPO Outputs Device), entry 0x04 (Global Reset)) | UINT32 | RO | 0xF707:04, 1 |
1608:04 | SubIndex 004 | 4. PDO Mapping entry (12 bits align) | UINT32 | RO | 0x0000:00, 12 |
Index 1609 DPO RxPDO-Map Extended Diag Outputs Device (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1609:0 | DPO RxPDO-Map Extended Diag Outputs Device | PDO Mapping RxPDO 10 | UINT8 | RO | 0x02 (2dec) |
1609:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF707 (DPO Outputs Device), entry 0x11 (Reset Extended Diag Data)) | UINT32 | RO | 0xF707:11, 1 |
1609:02 | SubIndex 002 | 2. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
Index 1610 LOG RxPDO-Map Control (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1610:0 | LOG RxPDO-Map Control | PDO Mapping RxPDO 17 | UINT8 | RO | 0x03 (3dec) |
1610:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x7040 (LOG Control), entry 0x01 (Start Logger)) | UINT32 | RO | 0x7040:01, 1 |
1610:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x7040 (LOG Control), entry 0x02 (Stop Logger)) | UINT32 | RO | 0x7040:02, 1 |
1610:03 | SubIndex 003 | 3. PDO Mapping entry (14 bits align) | UINT32 | RO | 0x0000:00, 14 |
Index 1A00 DPO TxPDO-Map Inputs Ch.1 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A00:0 | DPO TxPDO-Map Inputs Ch.1 | PDO Mapping TxPDO 1 | UINT8 | RO | 0x0E (14dec) |
1A00:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x01 (Error Us)) | UINT32 | RO | 0x6000:01, 1 |
1A00:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x02 (Error Up)) | UINT32 | RO | 0x6000:02, 1 |
1A00:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x03 (Warning Us)) | UINT32 | RO | 0x6000:03, 1 |
1A00:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x04 (Warning Up)) | UINT32 | RO | 0x6000:04, 1 |
1A00:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x05 (Status Us)) | UINT32 | RO | 0x6000:05, 1 |
1A00:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x06 (Status Up)) | UINT32 | RO | 0x6000:06, 1 |
1A00:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x07 (Channel Error)) | UINT32 | RO | 0x6000:07, 1 |
1A00:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x08 (Error Sum Current)) | UINT32 | RO | 0x6000:08, 1 |
1A00:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x09 (Warning Sum Current)) | UINT32 | RO | 0x6000:09, 1 |
1A00:0A | SubIndex 010 | 10. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A00:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x0F (TxPDO State)) | UINT32 | RO | 0x6000:0F, 1 |
1A00:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0x6000:10, 1 |
1A00:0D | SubIndex 013 | 13. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x11 (Current Us)) | UINT32 | RO | 0x6000:11, 16 |
1A00:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x12 (Current Up)) | UINT32 | RO | 0x6000:12, 16 |
Index 1A01 DPO TxPDO-Map Extended Diag Inputs Ch.1 (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A01:0 | DPO TxPDO-Map Extended Diag Inputs Ch.1 | PDO Mapping TxPDO 2 | UINT8 | RO | 0x04 (4dec) |
1A01:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x13 (Peak Value 1)) | UINT32 | RO | 0x6000:13, 16 |
1A01:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x14 (Peak Value 2)) | UINT32 | RO | 0x6000:14, 16 |
1A01:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x17 (Timestamp 1)) | UINT32 | RO | 0x6000:17, 64 |
1A01:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6000 (DPO Inputs Ch.1), entry 0x18 (Timestamp 2)) | UINT32 | RO | 0x6000:18, 64 |
1A01 DPO TxPDO-Map Inputs Ch.2 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A01:0 | DPO TxPDO-Map Inputs Ch.2 |
| USINT | RO | 0xb (11dec) |
1A01:01 | SubIndex 001 |
| UDINT | RO | 0x60100101 (1611661569dec) |
1A01:02 | SubIndex 002 |
| UDINT | RO | 0x60100201 (1611661825dec) |
1A01:03 | SubIndex 003 |
| UDINT | RO | 0x60100301 (1611662081dec) |
1A01:04 | SubIndex 004 |
| UDINT | RO | 0x60100401 (1611662337dec) |
1A01:05 | SubIndex 005 |
| UDINT | RO | 0x60100501 (1611662593dec) |
1A01:06 | SubIndex 006 |
| UDINT | RO | 0x60100601 (1611662849dec) |
1A01:07 | SubIndex 007 |
| UDINT | RO | 0x60100701 (1611663105dec) |
1A01:08 | SubIndex 008 |
| UDINT | RO | 0x6 (6dec) |
1A01:09 | SubIndex 009 |
| UDINT | RO | 0x60100e01 (1611664897dec) |
1A01:0A | SubIndex 010 |
| UDINT | RO | 0x60100f01 (1611665153dec) |
1A01:0B | SubIndex 011 |
| UDINT | RO | 0x60101001 (1611665409dec) |
1A02 DPO TxPDO-Map Inputs Ch.3 (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A02:0 | DPO TxPDO-Map Inputs Ch.3 |
| USINT | RO | 0xb (11dec) |
1A02:01 | SubIndex 001 |
| UDINT | RO | 0x60200101 (1612710145dec) |
1A02:02 | SubIndex 002 |
| UDINT | RO | 0x60200201 (1612710401dec) |
1A02:03 | SubIndex 003 |
| UDINT | RO | 0x60200301 (1612710657dec) |
1A02:04 | SubIndex 004 |
| UDINT | RO | 0x60200401 (1612710913dec) |
1A02:05 | SubIndex 005 |
| UDINT | RO | 0x60200501 (1612711169dec) |
1A02:06 | SubIndex 006 |
| UDINT | RO | 0x60200601 (1612711425dec) |
1A02:07 | SubIndex 007 |
| UDINT | RO | 0x60200701 (1612711681dec) |
1A02:08 | SubIndex 008 |
| UDINT | RO | 0x6 (6dec) |
1A02:09 | SubIndex 009 |
| UDINT | RO | 0x60200e01 (1612713473dec) |
1A02:0A | SubIndex 010 |
| UDINT | RO | 0x60200f01 (1612713729dec) |
1A02:0B | SubIndex 011 |
| UDINT | RO | 0x60201001 (1612713985dec) |
Index 1A02 DPO TxPDO-Map Inputs Ch.2 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A02:0 | DPO TxPDO-Map Inputs Ch.2 | PDO Mapping TxPDO 3 | UINT8 | RO | 0x0E (14dec) |
1A02:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x01 (Error Us)) | UINT32 | RO | 0x6010:01, 1 |
1A02:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x02 (Error Up)) | UINT32 | RO | 0x6010:02, 1 |
1A02:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x03 (Warning Us)) | UINT32 | RO | 0x6010:03, 1 |
1A02:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x04 (Warning Up)) | UINT32 | RO | 0x6010:04, 1 |
1A02:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x05 (Status Us)) | UINT32 | RO | 0x6010:05, 1 |
1A02:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x06 (Status Up)) | UINT32 | RO | 0x6010:06, 1 |
1A02:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x07 (Channel Error)) | UINT32 | RO | 0x6010:07, 1 |
1A02:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x08 (Error Sum Current)) | UINT32 | RO | 0x6010:08, 1 |
1A02:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x09 (Warning Sum Current)) | UINT32 | RO | 0x6010:09, 1 |
1A02:0A | SubIndex 010 | 10. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A02:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x0F (TxPDO State)) | UINT32 | RO | 0x6010:0F, 1 |
1A02:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0x6010:10, 1 |
1A02:0D | SubIndex 013 | 13. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x11 (Current Us)) | UINT32 | RO | 0x6010:11, 16 |
1A02:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x12 (Current Up)) | UINT32 | RO | 0x6010:12, 16 |
1A03 DPO TxPDO-Map Inputs Ch.4 (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A03:0 | DPO TxPDO-Map Inputs Ch.4 |
| USINT | RO | 0xb (11dec) |
1A03:01 | SubIndex 001 |
| UDINT | RO | 0x60300101 (1613758721dec) |
1A03:02 | SubIndex 002 |
| UDINT | RO | 0x60300201 (1613758977dec) |
1A03:03 | SubIndex 003 |
| UDINT | RO | 0x60300301 (1613759233dec) |
1A03:04 | SubIndex 004 |
| UDINT | RO | 0x60300401 (1613759489dec) |
1A03:05 | SubIndex 005 |
| UDINT | RO | 0x60300501 (1613759745dec) |
1A03:06 | SubIndex 006 |
| UDINT | RO | 0x60300601 (1613760001dec) |
1A03:07 | SubIndex 007 |
| UDINT | RO | 0x60300701 (1613760257dec) |
1A03:08 | SubIndex 008 |
| UDINT | RO | 0x6 (6dec) |
1A03:09 | SubIndex 009 |
| UDINT | RO | 0x60300e01 (1613762049dec) |
1A03:0A | SubIndex 010 |
| UDINT | RO | 0x60300f01 (1613762305dec) |
1A03:0B | SubIndex 011 |
| UDINT | RO | 0x60301001 (1613762561dec) |
Index 1A03 DPO TxPDO-Map Extended Diag Inputs Ch.2 (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A03:0 | DPO TxPDO-Map Extended Diag Inputs Ch.2 | PDO Mapping TxPDO 4 | UINT8 | RO | 0x04 (4dec) |
1A03:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x13 (Peak Value 1)) | UINT32 | RO | 0x6010:13, 16 |
1A03:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x14 (Peak Value 2)) | UINT32 | RO | 0x6010:14, 16 |
1A03:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x17 (Timestamp 1)) | UINT32 | RO | 0x6010:17, 64 |
1A03:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6010 (DPO Inputs Ch.2), entry 0x18 (Timestamp 2)) | UINT32 | RO | 0x6010:18, 64 |
1A04 DPO TxPDO-Map Inputs Device (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A04:0 | DPO TxPDO-Map Inputs Device |
| USINT | RO | 0xc (12dec) |
1A04:01 | SubIndex 001 |
| UDINT | RW | 0xf6070101 (4127654145dec) |
1A04:02 | SubIndex 002 |
| UDINT | RW | 0xf6070201 (4127654401dec) |
1A04:03 | SubIndex 003 |
| UDINT | RW | 0xf6070301 (4127654657dec) |
1A04:04 | SubIndex 004 |
| UDINT | RW | 0xf6070401 (4127654913dec) |
1A04:05 | SubIndex 005 |
| UDINT | RW | 0xf6070501 (4127655169dec) |
1A04:06 | SubIndex 006 |
| UDINT | RW | 0xf6070601 (4127655425dec) |
1A04:07 | SubIndex 007 |
| UDINT | RW | 0xf6070701 (4127655681dec) |
1A04:08 | SubIndex 008 |
| UDINT | RW | 0x4 (4dec) |
1A04:09 | SubIndex 009 |
| UDINT | RW | 0xf6070c01 (4127656961dec) |
1A04:0A | SubIndex 010 |
| UDINT | RW | 0x2 (2dec) |
1A04:0B | SubIndex 011 |
| UDINT | RW | 0xf6070f01 (4127657729dec) |
1A04:0C | SubIndex 012 |
| UDINT | RW | 0xf6071001 (4127657985dec) |
Index 1A04 DPO TxPDO-Map Inputs Ch.3 (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A04:0 | DPO TxPDO-Map Inputs Ch.3 | PDO Mapping TxPDO 5 | UINT8 | RO | 0x0E (14dec) |
1A04:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x01 (Error Us)) | UINT32 | RO | 0x6020:01, 1 |
1A04:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x02 (Error Up)) | UINT32 | RO | 0x6020:02, 1 |
1A04:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x03 (Warning Us)) | UINT32 | RO | 0x6020:03, 1 |
1A04:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x04 (Warning Up)) | UINT32 | RO | 0x6020:04, 1 |
1A04:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x05 (Status Us)) | UINT32 | RO | 0x6020:05, 1 |
1A04:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x06 (Status Up)) | UINT32 | RO | 0x6020:06, 1 |
1A04:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x07 (Channel Error)) | UINT32 | RO | 0x6020:07, 1 |
1A04:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x08 (Error Sum Current)) | UINT32 | RO | 0x6020:08, 1 |
1A04:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x09 (Warning Sum Current)) | UINT32 | RO | 0x6020:09, 1 |
1A04:0A | SubIndex 010 | 10. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A04:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x0F (TxPDO State)) | UINT32 | RO | 0x6020:0F, 1 |
1A04:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0x6020:10, 1 |
1A04:0D | SubIndex 013 | 13. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x11 (Current Us)) | UINT32 | RO | 0x6020:11, 16 |
1A04:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x12 (Current Up)) | UINT32 | RO | 0x6020:12, 16 |
Index 1A05 DPO TxPDO-Map Extended Diag Inputs Ch.3 (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A05:0 | DPO TxPDO-Map Extended Diag Inputs Ch.3 | PDO Mapping TxPDO 6 | UINT8 | RO | 0x04 (4dec) |
1A05:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x13 (Peak Value 1)) | UINT32 | RO | 0x6020:13, 16 |
1A05:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x14 (Peak Value 2)) | UINT32 | RO | 0x6020:14, 16 |
1A05:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x17 (Timestamp 1)) | UINT32 | RO | 0x6020:17, 64 |
1A05:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6020 (DPO Inputs Ch.3), entry 0x18 (Timestamp 2)) | UINT32 | RO | 0x6020:18, 64 |
Index 1A06 DPO TxPDO-Map Inputs Ch.4 (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A06:0 | DPO TxPDO-Map Inputs Ch.4 | PDO Mapping TxPDO 7 | UINT8 | RO | 0x0E (14dec) |
1A06:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x01 (Error Us)) | UINT32 | RO | 0x6030:01, 1 |
1A06:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x02 (Error Up)) | UINT32 | RO | 0x6030:02, 1 |
1A06:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x03 (Warning Us)) | UINT32 | RO | 0x6030:03, 1 |
1A06:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x04 (Warning Up)) | UINT32 | RO | 0x6030:04, 1 |
1A06:05 | SubIndex 005 | 5. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x05 (Status Us)) | UINT32 | RO | 0x6030:05, 1 |
1A06:06 | SubIndex 006 | 6. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x06 (Status Up)) | UINT32 | RO | 0x6030:06, 1 |
1A06:07 | SubIndex 007 | 7. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x07 (Channel Error)) | UINT32 | RO | 0x6030:07, 1 |
1A06:08 | SubIndex 008 | 8. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x08 (Error Sum Current)) | UINT32 | RO | 0x6030:08, 1 |
1A06:09 | SubIndex 009 | 9. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x09 (Warning Sum Current)) | UINT32 | RO | 0x6030:09, 1 |
1A06:0A | SubIndex 010 | 10. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A06:0B | SubIndex 011 | 11. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x0F (TxPDO State)) | UINT32 | RO | 0x6030:0F, 1 |
1A06:0C | SubIndex 012 | 12. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0x6030:10, 1 |
1A06:0D | SubIndex 013 | 13. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x11 (Current Us)) | UINT32 | RO | 0x6030:11, 16 |
1A06:0E | SubIndex 014 | 14. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x12 (Current Up)) | UINT32 | RO | 0x6030:12, 16 |
Index 1A07 DPO TxPDO-Map Extended Diag Inputs Ch.4 (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A07:0 | DPO TxPDO-Map Extended Diag Inputs Ch.4 | PDO Mapping TxPDO 8 | UINT8 | RO | 0x04 (4dec) |
1A07:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x13 (Peak Value 1)) | UINT32 | RO | 0x6030:13, 16 |
1A07:02 | SubIndex 002 | 2. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x14 (Peak Value 2)) | UINT32 | RO | 0x6030:14, 16 |
1A07:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x17 (Timestamp 1)) | UINT32 | RO | 0x6030:17, 64 |
1A07:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6030 (DPO Inputs Ch.4), entry 0x18 (Timestamp 2)) | UINT32 | RO | 0x6030:18, 64 |
Index 1A08 DPO TxPDO-Map Inputs Device (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A08:0 | DPO TxPDO-Map Inputs Device | PDO Mapping TxPDO 9 | UINT8 | RO | 0x11 (17dec) |
1A08:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x01 (Temperature Warning)) | UINT32 | RO | 0xF607:01, 1 |
1A08:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x02 (Temperature Error)) | UINT32 | RO | 0xF607:02, 1 |
1A08:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x03 (Us Warning)) | UINT32 | RO | 0xF607:03, 1 |
1A08:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x04 (Us Error)) | UINT32 | RO | 0xF607:04, 1 |
1A08:05 | SubIndex 005 | 5. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x05 (Up Warning)) | UINT32 | RO | 0xF607:05, 1 |
1A08:06 | SubIndex 006 | 6. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x06 (Up Error)) | UINT32 | RO | 0xF607:06, 1 |
1A08:07 | SubIndex 007 | 7. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x07 (Global Error Bit)) | UINT32 | RO | 0xF607:07, 1 |
1A08:08 | SubIndex 008 | 8. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x08 (Sum Current Warning)) | UINT32 | RO | 0xF607:08, 1 |
1A08:09 | SubIndex 009 | 9. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x09 (Sum Current Error)) | UINT32 | RO | 0xF607:09, 1 |
1A08:0A | SubIndex 010 | 10. PDO Mapping entry (5 bits align) | UINT32 | RO | 0x0000:00, 5 |
1A08:0B | SubIndex 011 | 11. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x0F (TxPDO State)) | UINT32 | RO | 0xF607:0F, 1 |
1A08:0C | SubIndex 012 | 12. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x10 (TxPDO Toggle)) | UINT32 | RO | 0xF607:10, 1 |
1A08:0D | SubIndex 013 | 13. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x11 (Current Us)) | UINT32 | RO | 0xF607:11, 16 |
1A08:0E | SubIndex 014 | 14. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x12 (Current Up)) | UINT32 | RO | 0xF607:12, 16 |
1A08:0F | SubIndex 015 | 15. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x13 (Voltage Us)) | UINT32 | RO | 0xF607:13, 16 |
1A08:10 | SubIndex 016 | 16. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x14 (Voltage Up)) | UINT32 | RO | 0xF607:14, 16 |
1A08:11 | SubIndex 017 | 17. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x15 (Temperature)) | UINT32 | RO | 0xF607:15, 16 |
Index 1A09 DPO TxPDO-Map Extended Diag Inputs Device (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A09:0 | DPO TxPDO-Map Extended Diag Inputs Device | PDO Mapping TxPDO 10 | UINT8 | RO | 0x04 (4dec) |
1A09:01 | SubIndex 001 | 1. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x16 (Peak Value 1)) | UINT32 | RO | 0xF607:16, 16 |
1A09:02 | SubIndex 002 | 2. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x17 (Peak Value 2)) | UINT32 | RO | 0xF607:17, 16 |
1A09:03 | SubIndex 003 | 3. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x18 (Timestamp 1)) | UINT32 | RO | 0xF607:18, 64 |
1A09:04 | SubIndex 004 | 4. PDO Mapping entry (object 0xF607 (DPO Inputs Device), entry 0x19 (Timestamp 2)) | UINT32 | RO | 0xF607:19, 64 |
Index 1A10 LOG TxPDO-Map Status (only EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1A10:0 | LOG TxPDO-Map Status | PDO Mapping TxPDO 17 | UINT8 | RO | 0x04 (4dec) |
1A10:01 | SubIndex 001 | 1. PDO Mapping entry (object 0x6040 (LOG Status), entry 0x01 (Logger Running)) | UINT32 | RO | 0x6040:01, 1 |
1A10:02 | SubIndex 002 | 2. PDO Mapping entry (15 bits align) | UINT32 | RO | 0x0000:00, 15 |
1A10:03 | SubIndex 003 | 3. PDO Mapping entry (object 0x6040 (LOG Status), entry 0x11 (Elapsed Time)) | UINT32 | RO | 0x6040:11, 32 |
1A10:04 | SubIndex 004 | 4. PDO Mapping entry (object 0x6040 (LOG Status), entry 0x12 (Trigger Reason)) | UINT32 | RO | 0x6040:12, 16 |
Index 1C00 Sync manager type
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C00:0 | Sync manager type | Using the Sync Managers | UINT8 | RO | 0x04 (4dec) |
1C00:01 | SubIndex 001 | Sync-Manager Type Channel 1: Mailbox Write | UINT8 | RO | 0x01 (1dec) |
1C00:02 | SubIndex 002 | Sync-Manager Type Channel 2: Mailbox Read | UINT8 | RO | 0x02 (2dec) |
1C00:03 | SubIndex 003 | Sync-Manager Type Channel 3: Process Data Write (Outputs) | UINT8 | RO | 0x03 (3dec) |
1C00:04 | SubIndex 004 | Sync-Manager Type Channel 4: Process Data Read (Inputs) | UINT8 | RO | 0x04 (4dec) |
1C12 RxPDO assign (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C12:0 | RxPDO assign |
| USINT | RO | 0x5 (5dec) |
1C12:01 | SubIndex 001 |
| UINT | RW | 0x1600 (5632dec) |
1C12:02 | SubIndex 002 |
| UINT | RW | 0x1601 (5633dec) |
1C12:03 | SubIndex 003 |
| UINT | RW | 0x1602 (5634dec) |
1C12:04 | SubIndex 004 |
| UINT | RW | 0x1603 (5635dec) |
1C12:05 | SubIndex 005 |
| UINT | RW | 0x1604 (5636dec) |
Index 1C12 RxPDO assign (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C12:0 | RxPDO assign | PDO Assign Outputs | UINT8 | RW | 0x05 (5dec) |
1C12:01 | Subindex 001 | 1. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1600 (5632dec) |
1C12:02 | Subindex 002 | 2. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1602 (5634dec) |
1C12:03 | Subindex 003 | 3. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1604 (5636dec) |
1C12:04 | Subindex 004 | 4. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1606 (5638dec) |
1C12:05 | Subindex 005 | 5. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x1608 (5640dec) |
1C12:06 | Subindex 006 | 6. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:07 | Subindex 007 | 7. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:08 | Subindex 008 | 8. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:09 | Subindex 009 | 9. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0A | Subindex 010 | 10. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C12:0B | Subindex 011 | 11. allocated RxPDO (contains the index of the associated RxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13 TxPDO assign (EP9214-0023, EP9214-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C13:0 | TxPDO assign |
| USINT | RO | 0x5 (5dec) |
1C13:01 | SubIndex 001 |
| UINT | RW | 0x1a00 (6656dec) |
1C13:02 | SubIndex 002 |
| UINT | RW | 0x1a01 (6657dec) |
1C13:03 | SubIndex 003 |
| UINT | RW | 0x1a02 (6658dec) |
1C13:04 | SubIndex 004 |
| UINT | RW | 0x1a03 (6659dec) |
1C13:05 | SubIndex 005 |
| UINT | RW | 0x1a04 (6660dec) |
Index 1C13 TxPDO assign (EP9224-0023, EP9224-0024)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C13:0 | TxPDO assign | PDO Assign Inputs | UINT8 | RW | 0x05 (5dec) |
1C13:01 | Subindex 001 | 1. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A00 (6656dec) |
1C13:02 | Subindex 002 | 2. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A02 (6658dec) |
1C13:03 | Subindex 003 | 3. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A04 (6660dec) |
1C13:04 | Subindex 004 | 4. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A06 (6662dec) |
1C13:05 | Subindex 005 | 5. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x1A08 (6664dec) |
1C13:06 | Subindex 006 | 6. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:07 | Subindex 007 | 7. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:08 | Subindex 008 | 8. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:09 | Subindex 009 | 9. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0A | Subindex 010 | 10. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
1C13:0B | Subindex 011 | 11. allocated TxPDO (contains the index of the associated TxPDO mapping object) | UINT16 | RW | 0x0000 (0dec) |
Index 1C32 SM output parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C32:0 | SM output parameter | Synchronization parameters for the outputs | UINT8 | RO | 0x20 (32dec) |
1C32:01 | Sync mode | Current synchronization mode:
| UINT16 | RW | 0x0000 (0dec) |
1C32:02 | Cycle time | Cycle time (in ns):
| UINT32 | RW | 0x000F4240 (1000000dec) |
1C32:03 | Shift time | Time between SYNC0 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:04 | Sync modes supported | Supported synchronization modes:
| UINT16 | RO | 0x0001 (1dec) |
1C32:05 | Minimum cycle time | Minimum cycle time (in ns) | UINT32 | RO | 0x000F4240 (1000000dec) |
1C32:06 | Calc and copy time | Minimum time between SYNC0 and SYNC1 event (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:07 | Minimum delay time |
| UINT32 | RO | 0x00000000 (0dec) |
1C32:08 | Get Cycle Time | Possible values:
The parameters 1C32:03, 1C32:05, 1C32:06, 1C32:09, 1C33:03, 1C33:06, 1C33:09 are updated with the maximum measured values. For a subsequent measurement the measured values are reset | UINT16 | RW | 0x0000 (0dec) |
1C32:09 | Maximum delay time | Time between SYNC1 event and output of the outputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C32:0B | SM event missed counter | Number of missed SM events in OPERATIONAL (DC mode only) | UINT16 | RO | 0x0000 (0dec) |
1C32:0C | Cycle exceeded counter | Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early) | UINT16 | RO | 0x0000 (0dec) |
1C32:0D | Shift too short counter | Number of occasions that the interval between SYNC0 and SYNC1 event was too short (DC mode only) | UINT16 | RO | 0x0000 (0dec) |
1C32:20 | Sync error | The synchronization was not correct in the last cycle (outputs were output too late; DC mode only) | BOOLEAN | RO | 0x00 (0dec) |
Index 1C33 SM input parameter
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
1C33:0 | SM input parameter | Synchronization parameters for the inputs | UINT8 | RO | 0x20 (32dec) |
1C33:01 | Sync mode | Current synchronization mode:
| UINT16 | RW | 0x0000 (0dec) |
1C33:02 | Cycle time | as 1C32:02 | UINT32 | RW | 0x000F4240 (1000000dec) |
1C33:03 | Shift time | Time between SYNC0 event and reading of the inputs (in ns, DC mode only) | UINT32 | RO | 0x00000000 (0dec) |
1C33:04 | Sync modes supported | Supported synchronization modes:
| UINT16 | RO | 0x0001 (1dec) |
1C33:05 | Minimum cycle time | as 1C32:05 | UINT32 | RO | 0x000F4240 (1000000dec) |
1C33:06 | Calc and copy time | Time between reading of the inputs and availability of the inputs for the master (in ns, only DC mode) | UINT32 | RO | 0x00000000 (0dec) |
1C33:07 | Minimum delay time |
| UINT32 | RO | 0x00000000 (0dec) |
1C33:08 | Get Cycle Time | as 1C32:08 | UINT16 | RW | 0x0000 (0dec) |
1C33:09 | Maximum delay time | Time between SYNC1 event and reading of the inputs (in ns, only DC mode) | UINT32 | RO | 0x00000000 (0dec) |
1C33:0B | SM event missed counter | as 1C32:11 | UINT16 | RO | 0x0000 (0dec) |
1C33:0C | Cycle exceeded counter | as 1C32:12 | UINT16 | RO | 0x0000 (0dec) |
1C33:0D | Shift too short counter | as 1C32:13 | UINT16 | RO | 0x0000 (0dec) |
1C33:20 | Sync error | as 1C32:32 | BOOLEAN | RO | 0x00 (0dec) |
F000 Modular Device Profile
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F000:0 | Modular Device Profile |
| USINT | RO | 0x2 (2dec) |
F000:01 | Index distance |
| UINT | RO | 0x10 (16dec) |
F000:02 | Maximum number of modules |
| UINT | RO | 0x4 (4dec) |
F008 Code word
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F008:0 | Code word | - | UDINT | RO | - |
F010 Module Profile List
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F010:0 | Module Profile List |
| USINT | RO | 0x4 (4dec) |
F010:01 | SubIndex 001 |
| UDINT | RO | 0x10e (270dec) |
F010:02 | SubIndex 002 |
| UDINT | RO | 0x10e (270dec) |
F010:03 | SubIndex 003 |
| UDINT | RO | 0x10e (270dec) |
F010:04 | SubIndex 004 |
| UDINT | RO | 0x10e (270dec) |