Profile-specific objects
6000 DPO Inputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6000:0 | DPO Inputs Ch.1 |
| USINT | RO | 0x18 (24dec) |
6000:01 | Error Us | - | BOOL | RO | - |
6000:02 | Error Up | - | BOOL | RO | - |
6000:03 | Warning Us | - | BOOL | RO | - |
6000:04 | Warning Up | - | BOOL | RO | - |
6000:05 | Status Us | - | BOOL | RO | - |
6000:06 | Status Up | - | BOOL | RO | - |
6000:07 | Channel Error | - | BOOL | RO | - |
6000:08 | Error Sum Current | - | BOOL | RO | - |
6000:09 | Warning Sum Current | - | BOOL | RO | - |
6000:0F | TxPDO State | - | BOOL | RO | - |
6000:10 | TxPDO Toggle | - | BOOL | RO | - |
6000:11 | Current Us | - | INT | RO | - |
6000:12 | Current Up | - | INT | RO | - |
6000:13 | Peak Value 1 | - | INT | RO | - |
6000:14 | Peak Value 2 | - | INT | RO | - |
6000:17 | Timestamp 1 | - | ULINT | RO | - |
6000:18 | Timestamp 2 | - | ULINT | RO | - |
6010 DPO Inputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6010:0 | DPO Inputs Ch.2 |
| USINT | RO | 0x18 (24dec) |
6010:01 | Error Us | - | BOOL | RO | - |
6010:02 | Error Up | - | BOOL | RO | - |
6010:03 | Warning Us | - | BOOL | RO | - |
6010:04 | Warning Up | - | BOOL | RO | - |
6010:05 | Status Us | - | BOOL | RO | - |
6010:06 | Status Up | - | BOOL | RO | - |
6010:07 | Channel Error | - | BOOL | RO | - |
6010:08 | Error Sum Current | - | BOOL | RO | - |
6010:09 | Warning Sum Current | - | BOOL | RO | - |
6010:0F | TxPDO State | - | BOOL | RO | - |
6010:10 | TxPDO Toggle | - | BOOL | RO | - |
6010:11 | Current Us | - | INT | RO | - |
6010:12 | Current Up | - | INT | RO | - |
6010:13 | Peak Value 1 | - | INT | RO | - |
6010:14 | Peak Value 2 | - | INT | RO | - |
6010:17 | Timestamp 1 | - | ULINT | RO | - |
6010:18 | Timestamp 2 | - | ULINT | RO | - |
6020 DPO Inputs Ch.3
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6020:0 | DPO Inputs Ch.3 |
| USINT | RO | 0x18 (24dec) |
6020:01 | Error Us | - | BOOL | RO | - |
6020:02 | Error Up | - | BOOL | RO | - |
6020:03 | Warning Us | - | BOOL | RO | - |
6020:04 | Warning Up | - | BOOL | RO | - |
6020:05 | Status Us | - | BOOL | RO | - |
6020:06 | Status Up | - | BOOL | RO | - |
6020:07 | Channel Error | - | BOOL | RO | - |
6020:08 | Error Sum Current | - | BOOL | RO | - |
6020:09 | Warning Sum Current | - | BOOL | RO | - |
6020:0F | TxPDO State | - | BOOL | RO | - |
6020:10 | TxPDO Toggle | - | BOOL | RO | - |
6020:11 | Current Us | - | INT | RO | - |
6020:12 | Current Up | - | INT | RO | - |
6020:13 | Peak Value 1 | - | INT | RO | - |
6020:14 | Peak Value 2 | - | INT | RO | - |
6020:17 | Timestamp 1 | - | ULINT | RO | - |
6020:18 | Timestamp 2 | - | ULINT | RO | - |
6030 DPO Inputs Ch.4
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6030:0 | DPO Inputs Ch.4 |
| USINT | RO | 0x18 (24dec) |
6030:01 | Error Us | - | BOOL | RO | - |
6030:02 | Error Up | - | BOOL | RO | - |
6030:03 | Warning Us | - | BOOL | RO | - |
6030:04 | Warning Up | - | BOOL | RO | - |
6030:05 | Status Us | - | BOOL | RO | - |
6030:06 | Status Up | - | BOOL | RO | - |
6030:07 | Channel Error | - | BOOL | RO | - |
6030:08 | Error Sum Current | - | BOOL | RO | - |
6030:09 | Warning Sum Current | - | BOOL | RO | - |
6030:0F | TxPDO State | - | BOOL | RO | - |
6030:10 | TxPDO Toggle | - | BOOL | RO | - |
6030:11 | Current Us | - | INT | RO | - |
6030:12 | Current Up | - | INT | RO | - |
6030:13 | Peak Value 1 | - | INT | RO | - |
6030:14 | Peak Value 2 | - | INT | RO | - |
6030:17 | Timestamp 1 | - | ULINT | RO | - |
6030:18 | Timestamp 2 | - | ULINT | RO | - |
6040 LOG Status
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6040:0 | LOG Status |
| USINT | RO | 0x12 (18dec) |
6040:01 | Logger Running | - | BOOL | RO | - |
6040:11 | Elapsed Time | - | UDINT | RO | - |
6040:12 | Trigger Reason | - | UINT | RO | - |
7000 DPO Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7000:0 | DPO Outputs Ch.1 |
| USINT | RO | 0x11 (17dec) |
7000:01 | Output Us | - | BOOL | RO | - |
7000:02 | Output Up | - | BOOL | RO | - |
7000:05 | Reset Us | - | BOOL | RO | - |
7000:06 | Reset Up | - | BOOL | RO | - |
7000:11 | Reset Extended Diag Data | - | BOOL | RO | - |
7010 DPO Outputs Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7010:0 | DPO Outputs Ch.2 |
| USINT | RO | 0x11 (17dec) |
7010:01 | Output Us | - | BOOL | RO | - |
7010:02 | Output Up | - | BOOL | RO | - |
7010:05 | Reset Us | - | BOOL | RO | - |
7010:06 | Reset Up | - | BOOL | RO | - |
7010:11 | Reset Extended Diag Data | - | BOOL | RO | - |
7020 DPO Outputs Ch.3
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7020:0 | DPO Outputs Ch.3 |
| USINT | RO | 0x11 (17dec) |
7020:01 | Output Us | - | BOOL | RO | - |
7020:02 | Output Up | - | BOOL | RO | - |
7020:05 | Reset Us | - | BOOL | RO | - |
7020:06 | Reset Up | - | BOOL | RO | - |
7020:11 | Reset Extended Diag Data | - | BOOL | RO | - |
7030 DPO Outputs Ch.4
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7030:0 | DPO Outputs Ch.4 |
| USINT | RO | 0x11 (17dec) |
7030:01 | Output Us | - | BOOL | RO | - |
7030:02 | Output Up | - | BOOL | RO | - |
7030:05 | Reset Us | - | BOOL | RO | - |
7030:06 | Reset Up | - | BOOL | RO | - |
7030:11 | Reset Extended Diag Data | - | BOOL | RO | - |
7040 LOG Control
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7040:0 | LOG Control |
| USINT | RO | 0x2 (2dec) |
7040:01 | Start Logger | - | BOOL | RO | - |
7040:02 | Stop Logger | - | BOOL | RO | - |
F607 DPO Inputs Device
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F607:0 | DPO Inputs Device |
| USINT | RO | 0x19 (25dec) |
F607:01 | Warning Temperature | - | BOOL | RO | - |
F607:02 | Error Temperature | - | BOOL | RO | - |
F607:03 | Warning Us | - | BOOL | RO | - |
F607:04 | Error Us | - | BOOL | RO | - |
F607:05 | Warning Up | - | BOOL | RO | - |
F607:06 | Error Up | - | BOOL | RO | - |
F607:07 | Global Error Bit | - | BOOL | RO | - |
F607:08 | Warning Sum Current | - | BOOL | RO | - |
F607:09 | Error Sum Current | - | BOOL | RO | - |
F607:0F | TxPDO State | - | BOOL | RO | - |
F607:10 | TxPDO Toggle | - | BOOL | RO | - |
F607:11 | Current Us | - | INT | RO | - |
F607:12 | Current Up | - | INT | RO | - |
F607:13 | Voltage Us | - | INT | RO | - |
F607:14 | Voltage Up | - | INT | RO | - |
F607:15 | Temperature | - | INT | RO | - |
F607:16 | Peak Value 1 | - | INT | RO | - |
F607:17 | Peak Value 2 | - | INT | RO | - |
F607:18 | Timestamp 1 | - | ULINT | RO | - |
F607:19 | Timestamp 2 | - | ULINT | RO | - |
F707 DPO Outputs Device
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F707:0 | DPO Outputs Device |
| USINT | RO | 0x11 (17dec) |
F707:01 | Enable Control Via Fieldbus | - | BOOL | RO | - |
F707:04 | Global Reset | - | BOOL | RO | - |
F707:11 | Reset Extended Diag Data | - | BOOL | RO | - |