Technical data

All values are typical values over the entire temperature range, unless stated otherwise.

EtherCAT

Connection

Input: M8 female socket, 4-pin, A-coded

Forwarding: M8 male plug, 4-pin, A-coded

Connection cables

PUR green 4 x AWG26

UL AWM 20963 (internal use), UL rating 30 V, UL fire class FT 2

Minimum bending radius: approx. 15 mm

Connection cable length

Input: 2.0 m

Forwarding: 0.15 m

Power supply

Nominal voltage US

24 VDC (-15 % / +20 %)

Nominal voltage UP

24 ... 48 VDC

Connection

Input: 1 x M12 male plug, 5-pin, L-coded

Forwarding: 1 x M12 female socket, 5-pin, L-coded

Connection cables

PVC 5 x 2.5 mm²

UL AWM 20549 (internal use), UL rating 300 V, UL fire class FT 2

Minimum bending radius: approx. 40 mm

Connection cable length

Input: 2.0 m

Forwarding: 0.15 m

Current consumption from US

150 mA + load

Current consumption from UP

Depending on the application

Total current US

max. 16 A at the input

Total current UP

max. 16 A at the input

Motor channels

EP7414-0071

EP7414-9071

Number

4

Motor type

BLDC motor

Connection

1 x M8 male plug per channel, 4-pin, A-coded

Connection cables

PUR Type 1.1 with 4 x 0.5 mm²

UL AWM 20549 (internal use), UL rating 300 V, UL fire class FT 2

Minimum bending radius: approx. 25 mm

Connection cable length

  • X20, channel 1: 0.15 m
  • X21, channel 2: 0.65 m
  • X22, channel 3: 0.15 m
  • X23, channel 4: 1.5 m

Winding inductance

min. 300 µH

Output current per channel

4 A RMS

Peak current per channel

8 A for 1 s

Drive profile

DS402

Safe stop functions

-

Safe Torque Off (STO)

Safe Torque Off implementation

-

via FSoE

Safety standards

-

  • EN ISO 13849-1:2015 (Cat 3, PL e)
  • EN 61508:2010 (SIL 3)
  • EN 62061:2005 + A1:2013/A2:2015 (SIL CL3)

Rotating field frequency

0 … 599 Hz

PWM clock frequency

16 kHz

Current controller frequency

32 kHz

Position controller frequency

16 kHz

Speed controller frequency

16 kHz

Digital combi channels per motor channel

Number

2

Connection

1 x M12 female socket, 5-pin, A-coded

Connection cables

PVC 4 x 0.14 mm²

UL AWM 2095 (internal use), UL rating 300 V, UL fire class FT 2

Minimum bending radius: approx. 23 mm

Connection cable length

  • X01: 0.15 m
  • X02: 0.65 m
  • X03: 0.15 m
  • X04: 1.5 m

Nominal input voltage

24 VDC

Input characteristics

Type 3 according to EN 61131-2, compatible with type 1

Nominal output voltage

24 VDC from US, short-circuit proof

Output current

max. 0.5 A per output

Total output current

max. 1 A per connection, including sensor power supply

Sensor power supply

24 VDC from US, short-circuit proof

max. 0.5 A per motor channel 1+2
max. 0.5 A per motor channel 3+4

Housing data

Dimensions W × H × D

309 mm × 94 mm × 25 mm

Weight

1400 g

Installation position

Any

Materials

Aluminum, PC/ABS

Mounting

Two mounting holes Ø6.5 mm for M6

Ambient conditions

Ambient temperature during operation

0 ... 50 °C

Ambient temperature during storage

-25 ... +85 °C

Vibration / shock resistance

in accordance with EN 60068-2-6 / EN 60068-2-27

EMC immunity / emission

in accordance with EN 61000-6-2 / EN 61000-6-4

Protection rating

IP54 according to EN 60529

Approvals

EP7414-0071

EP7414-9071

Approvals

CE, UL

CE, UL, TÜV SÜD