Status LEDs

Status LEDs 1:

LED

Signal

Meaning

Motor CH1

off

Motor channel 1 is disabled.

You can enable it by setting "Enable" to 1 in the process data object STM Control Channel 1.

green illuminated

Motor channel 1 is enabled.

red illuminated

Motor channel 1 has been blocked due to an error. Check the diagnostic bits to determine the cause of the error.

Warning

orange illuminated

Warning message.

Check the diagnostic bits to determine the cause of the warning message.

Motor CH2

off

Motor channel 2 is disabled.

You can enable it by setting "Enable" to 1 in the process data object STM Control Channel 2.

green illuminated

Motor channel 2 is enabled.

red illuminated

Motor channel 2 has been blocked due to an error.

Check the diagnostic bits to determine the cause of the error.