Profile-specific objects
6000 ENC Inputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6000:0 | ENC Inputs Ch.1 |
| USINT | RO | 0x11 (17dec) |
6000:03 | Set counter done | - | BOOL | RO | - |
6000:04 | Counter underflow | - | BOOL | RO | - |
6000:05 | Counter overflow | - | BOOL | RO | - |
6000:0E | Sync error | - | BOOL | RO | - |
6000:10 | TxPDO Toggle | - | BOOL | RO | - |
6000:11 | Counter value | - | UDINT | RO | - |
6010 STM Inputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6010:0 | STM Inputs Ch.1 |
| USINT | RO | 0x15 (21dec) |
6010:01 | Ready to enable | - | BOOL | RO | - |
6010:02 | Ready | - | BOOL | RO | - |
6010:03 | Warning | - | BOOL | RO | - |
6010:04 | Error | - | BOOL | RO | - |
6010:05 | Moving positive | - | BOOL | RO | - |
6010:06 | Moving negative | - | BOOL | RO | - |
6010:07 | Torque reduced | - | BOOL | RO | - |
6010:08 | Motor stall | - | BOOL | RO | - |
6010:0C | Digital input 1 | - | BOOL | RO | - |
6010:0D | Digital input 2 | - | BOOL | RO | - |
6010:0E | Sync error | - | BOOL | RO | - |
6010:10 | TxPDO Toggle | - | BOOL | RO | - |
6010:11 | Info data 1 | - | UINT | RO | - |
6010:12 | Info data 2 | - | UINT | RO | - |
6010:13 | Motor load | - | UINT | RO | - |
6010:14 | Internal position | - | UDINT | RO | - |
6010:15 | External position | - | UDINT | RO | - |
6020 POS Inputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6020:0 | POS Inputs Ch.1 |
| USINT | RO | 0x23 (35dec) |
6020:01 | Busy | - | BOOL | RO | - |
6020:02 | In-Target | - | BOOL | RO | - |
6020:03 | Warning | - | BOOL | RO | - |
6020:04 | Error | - | BOOL | RO | - |
6020:05 | Calibrated | - | BOOL | RO | - |
6020:06 | Accelerate | - | BOOL | RO | - |
6020:07 | Decelerate | - | BOOL | RO | - |
6020:08 | Ready to execute | - | BOOL | RO | - |
6020:11 | Actual position | - | UDINT | RO | - |
6020:21 | Actual velocity | - | INT | RO | - |
6020:22 | Actual drive time | - | UDINT | RO | - |
6020:23 | Actual position lag | - | DINT | RO | - |
7000 ENC Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7000:0 | ENC Outputs Ch.1 |
| USINT | RO | 0x11 (17dec) |
7000:03 | Set counter | - | BOOL | RO | - |
7000:11 | Set counter value | - | UDINT | RO | - |
7010 STM Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7010:0 | STM Outputs Ch.1 |
| USINT | RO | 0x21 (33dec) |
7010:01 | Enable | - | BOOL | RO | - |
7010:02 | Reset | - | BOOL | RO | - |
7010:03 | Reduce torque | - | BOOL | RO | - |
7010:0C | Digital output 1 | - | BOOL | RO | - |
7010:11 | Position | - | UDINT | RO | - |
7010:21 | Velocity | - | INT | RO | - |
7020 POS Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7020:0 | POS Outputs Ch.1 |
| USINT | RO | 0x24 (36dec) |
7020:01 | Execute | - | BOOL | RO | - |
7020:02 | Emergency stop | - | BOOL | RO | - |
7020:11 | Target position | - | UDINT | RO | - |
7020:21 | Velocity | - | INT | RO | - |
7020:22 | Start type | - | UINT | RO | - |
7020:23 | Acceleration | - | UINT | RO | - |
7020:24 | Deceleration | - | UINT | RO | - |
7021 POS Outputs 2 Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7021:0 | POS Outputs 2 Ch.1 |
| USINT | RO | 0x24 (36dec) |
7021:03 | Enable auto start | - | BOOL | RO | - |
7021:11 | Target position | - | UDINT | RO | - |
7021:21 | Velocity | - | INT | RO | - |
7021:22 | Start type | - | UINT | RO | - |
7021:23 | Acceleration | - | UINT | RO | - |
7021:24 | Deceleration | - | UINT | RO | - |