Profile-specific objects
Index 6000 AI Acc Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6000:0 | AI Acc Inputs |
| UINT8 | RO | 0x14 (20dec) |
6000:09 | Self test status |
| BIT2 | RO | 0x00 (0dec) |
6000:0B | Slope detected |
| BOOLEAN | RO | 0x00 (0dec) |
6000:0E | Sync error |
| BOOLEAN | RO | 0x00 (0dec) |
6000:0F | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec) |
6000:10 | TxPDO Toggle |
| BOOLEAN | RO | 0x00 (0dec) |
6000:12 | Value |
| INT32 | RO | 0x00000000 (0dec) |
6000:13 | Value (Real32) |
| REAL32 | RO | 0x00000000 (0dec) |
6000:14 | Input Cycle Counter |
| UINT16 | RO | 0x0000 (0dec) |
Index 6001 AI Acc Samples
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6001:0 | AI Acc Samples |
| UINT8 | RO | 0x28 (40dec) |
6001:01 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6001:02 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6001:03 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6001:26 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6001:27 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6001:28 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
Index 6003 AI Acc Samples (Real32)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6003:0 | AI Acc Samples (Real32) |
| UINT8 | RO | 0x28 (40dec) |
6003:01 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6003:02 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6003:03 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6003:26 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6003:27 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6003:28 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
Index 6010 AI Acc Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6010:0 | AI Acc Inputs |
| UINT8 | RO | 0x14 (20dec) |
6010:09 | Self test status |
| BIT2 | RO | 0x00 (0dec) |
6010:0B | Slope detected |
| BOOLEAN | RO | 0x00 (0dec) |
6010:0E | Sync error |
| BOOLEAN | RO | 0x00 (0dec) |
6010:0F | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec) |
6010:10 | TxPDO Toggle |
| BOOLEAN | RO | 0x00 (0dec) |
6010:12 | Value |
| INT32 | RO | 0x00000000 (0dec) |
6010:13 | Value (Real32) |
| REAL32 | RO | 0x00000000 (0dec) |
6010:14 | Input Cycle Counter |
| UINT16 | RO | 0x0000 (0dec) |
Index 6011 AI Acc Samples
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6011:0 | AI Acc Samples |
| UINT8 | RO | 0x28 (40dec) |
6011:01 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6011:02 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6011:03 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6011:26 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6011:27 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6011:28 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
Index 6013 AI Acc Samples (Real32)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6013:0 | AI Acc Samples (Real32) |
| UINT8 | RO | 0x28 (40dec) |
6013:01 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6013:02 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6013:03 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6013:26 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6013:27 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6013:28 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
Index 6020 AI Acc Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6020:0 | AI Acc Inputs |
| UINT8 | RO | 0x14 (20dec) |
6020:09 | Self test status |
| BIT2 | RO | 0x00 (0dec) |
6020:0B | Slope detected |
| BOOLEAN | RO | 0x00 (0dec) |
6020:0E | Sync error |
| BOOLEAN | RO | 0x00 (0dec) |
6020:0F | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec) |
6020:10 | TxPDO Toggle |
| BOOLEAN | RO | 0x00 (0dec) |
6020:12 | Value |
| INT32 | RO | 0x00000000 (0dec) |
6020:13 | Value (Real32) |
| REAL32 | RO | 0x00000000 (0dec) |
6020:14 | Input Cycle Counter |
| UINT16 | RO | 0x0000 (0dec) |
Index 6021 AI Acc Samples
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6021:0 | AI Acc Samples |
| UINT8 | RO | 0x28 (40dec) |
6021:01 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6021:02 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6021:03 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6021:26 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6021:27 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6021:28 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
Index 6023 AI Acc Samples (Real32)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6023:0 | AI Acc Samples (Real32) |
| UINT8 | RO | 0x28 (40dec) |
6023:01 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6023:02 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6023:03 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6023:26 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6023:27 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6023:28 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
Index 6030 AI Gyro Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6030:0 | AI Gyro Inputs |
| UINT8 | RO | 0x14 (20dec) |
6030:09 | Self test status |
| BIT2 | RO | 0x00 (0dec) |
6030:0B | Slope detected |
| BOOLEAN | RO | 0x00 (0dec) |
6030:0E | Sync error |
| BOOLEAN | RO | 0x00 (0dec) |
6030:0F | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec) |
6030:10 | TxPDO Toggle |
| BOOLEAN | RO | 0x00 (0dec) |
6030:12 | Value |
| INT32 | RO | 0x00000000 (0dec) |
6030:13 | Value (Real32) |
| REAL32 | RO | 0x00000000 (0dec) |
6030:14 | Input Cycle Counter |
| UINT16 | RO | 0x0000 (0dec) |
Index 6031 AI Gyro Samples
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6031:0 | AI Gyro Samples |
| UINT8 | RO | 0x28 (40dec) |
6031:01 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6031:02 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6031:03 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6031:26 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6031:27 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6031:28 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
Index 6033 AI Gyro Samples (Real32)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6033:0 | AI Gyro Samples (Real32) |
| UINT8 | RO | 0x28 (40dec) |
6033:01 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6033:02 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6033:03 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6033:26 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6033:27 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6033:28 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
Index 6040 AI Gyro Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6040:0 | AI Gyro Inputs |
| UINT8 | RO | 0x14 (20dec) |
6040:09 | Self test status |
| BIT2 | RO | 0x00 (0dec) |
6040:0B | Slope detected |
| BOOLEAN | RO | 0x00 (0dec) |
6040:0E | Sync error |
| BOOLEAN | RO | 0x00 (0dec) |
6040:0F | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec) |
6040:10 | TxPDO Toggle |
| BOOLEAN | RO | 0x00 (0dec) |
6040:12 | Value |
| INT32 | RO | 0x00000000 (0dec) |
6040:13 | Value (Real32) |
| REAL32 | RO | 0x00000000 (0dec) |
6040:14 | Input Cycle Counter |
| UINT16 | RO | 0x0000 (0dec) |
Index 6041 AI Gyro Samples
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6041:0 | AI Gyro Samples |
| UINT8 | RO | 0x28 (40dec) |
6041:01 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6041:02 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6041:03 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6041:26 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6041:27 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6041:28 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
Index 6043 AI Gyro Samples (Real32)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6043:0 | AI Gyro Samples (Real32) |
| UINT8 | RO | 0x28 (40dec) |
6043:01 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6043:02 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6043:03 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | …s |
6043:26 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6043:27 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6043:28 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
Index 6050 AI Gyro Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6050:0 | AI Gyro Inputs |
| UINT8 | RO | 0x14 (20dec) |
6050:09 | Self test status |
| BIT2 | RO | 0x00 (0dec) |
6050:0B | Slope detected |
| BOOLEAN | RO | 0x00 (0dec) |
6050:0E | Sync error |
| BOOLEAN | RO | 0x00 (0dec) |
6050:0F | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec) |
6050:10 | TxPDO Toggle |
| BOOLEAN | RO | 0x00 (0dec) |
6050:12 | Value |
| INT32 | RO | 0x00000000 (0dec) |
6050:13 | Value (Real32) |
| REAL32 | RO | 0x00000000 (0dec) |
6050:14 | Input Cycle Counter |
| UINT16 | RO | 0x0000 (0dec) |
Index 6051 AI Gyro Samples
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6051:0 | AI Gyro Samples |
| UINT8 | RO | 0x28 (40dec) |
6051:01 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6051:02 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6051:03 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6051:26 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6051:27 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
6051:28 | Sample |
| INT32 | RO | 0x00000000 (0dec) |
Index 6053 AI Gyro Samples (Real32)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6053:0 | AI Gyro Samples (Real32) |
| UINT8 | RO | 0x28 (40dec) |
6053:01 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6053:02 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6053:03 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
… | … | … | … | … | … |
6053:26 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6053:27 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
6053:28 | Sample |
| REAL32 | RO | 0x00000000 (0dec) |
Index 6060 AI Temp Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6060:0 | AI Temp Inputs |
| UINT8 | RO | 0x13 (19dec) |
6060:0E | Sync error |
| BOOLEAN | RO | 0x00 (0dec) |
6060:0F | TxPDO State |
| BOOLEAN | RO | 0x00 (0dec) |
6060:10 | TxPDO Toggle |
| BOOLEAN | RO | 0x00 (0dec) |
6060:12 | Value |
| INT32 | RO | 0x00000000 (0dec) |
6060:13 | Value (Real32) |
| REAL32 | RO | 0x00000000 (0dec) |
Index 7070 DIG Outputs Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
7070:0 | DIG Outputs Ch.1 |
| UINT8 | RO | 0x03 (3dec) |
7070:01 | LED 1 |
| BOOLEAN | RO | 0x00 (0dec) |
7070:02 | LED 2 |
| BOOLEAN | RO | 0x00 (0dec) |
7070:03 | LED 3 |
| BOOLEAN | RO | 0x00 (0dec) |
Index F000 Modular Device Profile
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F000:0 | Modular Device Profile | General information for the Modular Device Profile | UINT8 | RO | 0x02 (2dec) |
F000:01 | Index distance | Index distance of the objects of the individual channels | UINT16 | RO | 0x0010 (16dec) |
F000:02 | Maximum number of modules | Number of channels | UINT16 | RO | 0x0008 (8dec) |
Index F008 Code word
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F008:0 | Code word |
| UINT32 | RW | 0x00000000 (0dec) |
Index F010 Module Profile List
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F010:0 | Module Profile List |
| UINT8 | RO | 0x08 (8dec) |
F010:01 | SubIndex 001 |
| UINT32 | RO | 0x0000012C (300dec) |
F010:02 | SubIndex 002 |
| UINT32 | RO | 0x0000012C (300dec) |
F010:03 | SubIndex 003 |
| UINT32 | RO | 0x0000012C (300dec) |
F010:04 | SubIndex 004 |
| UINT32 | RO | 0x0000012C (300dec) |
F010:05 | SubIndex 005 |
| UINT32 | RO | 0x0000012C (300dec) |
F010:06 | SubIndex 006 |
| UINT32 | RO | 0x0000012C (300dec) |
F010:07 | SubIndex 007 |
| UINT32 | RO | 0x0000012C (300dec) |
F010:08 | SubIndex 008 |
| UINT32 | RO | 0x00000118 (280dec) |
Index F912 Filter info
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
F912:0 | Filter info |
| UINT8 | RO | 0x07 (7dec) |
F912:01 | Info header |
| OCTET-STRING[8] | RO | {0} |
F912:02 | Filter 1 |
| OCTET-STRING[30] | RO | {0} |
F912:03 | Filter 2 |
| OCTET-STRING[30] | RO | {0} |
F912:04 | Filter 3 |
| OCTET-STRING[30] | RO | {0} |
F912:05 | Filter 4 |
| OCTET-STRING[30] | RO | {0} |
F912:06 | Filter 5 |
| OCTET-STRING[30] | RO | {0} |
F912:07 | Filter 6 |
| OCTET-STRING[30] | RO | {0} |
Index FB10 CMD Command
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
FB10:0 | CMD Command |
| UINT8 | RO | 0x03 (3dec) |
FB10:01 | Request |
| OCTET-STRING[6] | RW | {0} |
FB10:02 | Status |
| UINT8 | RO | 0x00 (0dec) |
FB10:03 | Response |
| OCTET-STRING[6] | RO | {0} |