Profile-specific objects
Index 6000 AI Acc Inputs
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6000:0 | AI Acc Inputs | 
 | UINT8 | RO | 0x14 (20dec) | 
| 6000:09 | Self test status | 
 | BIT2 | RO | 0x00 (0dec) | 
| 6000:0B | Slope detected | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6000:0E | Sync error | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6000:0F | TxPDO State | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6000:10 | TxPDO Toggle | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6000:12 | Value | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6000:13 | Value (Real32) | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6000:14 | Input Cycle Counter | 
 | UINT16 | RO | 0x0000 (0dec) | 
Index 6001 AI Acc Samples
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6001:0 | AI Acc Samples | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6001:01 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6001:02 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6001:03 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6001:26 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6001:27 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6001:28 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
Index 6003 AI Acc Samples (Real32)
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6003:0 | AI Acc Samples (Real32) | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6003:01 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6003:02 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6003:03 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6003:26 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6003:27 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6003:28 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
Index 6010 AI Acc Inputs
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6010:0 | AI Acc Inputs | 
 | UINT8 | RO | 0x14 (20dec) | 
| 6010:09 | Self test status | 
 | BIT2 | RO | 0x00 (0dec) | 
| 6010:0B | Slope detected | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6010:0E | Sync error | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6010:0F | TxPDO State | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6010:10 | TxPDO Toggle | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6010:12 | Value | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6010:13 | Value (Real32) | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6010:14 | Input Cycle Counter | 
 | UINT16 | RO | 0x0000 (0dec) | 
Index 6011 AI Acc Samples
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6011:0 | AI Acc Samples | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6011:01 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6011:02 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6011:03 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6011:26 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6011:27 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6011:28 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
Index 6013 AI Acc Samples (Real32)
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6013:0 | AI Acc Samples (Real32) | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6013:01 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6013:02 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6013:03 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6013:26 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6013:27 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6013:28 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
Index 6020 AI Acc Inputs
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6020:0 | AI Acc Inputs | 
 | UINT8 | RO | 0x14 (20dec) | 
| 6020:09 | Self test status | 
 | BIT2 | RO | 0x00 (0dec) | 
| 6020:0B | Slope detected | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6020:0E | Sync error | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6020:0F | TxPDO State | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6020:10 | TxPDO Toggle | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6020:12 | Value | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6020:13 | Value (Real32) | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6020:14 | Input Cycle Counter | 
 | UINT16 | RO | 0x0000 (0dec) | 
Index 6021 AI Acc Samples
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6021:0 | AI Acc Samples | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6021:01 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6021:02 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6021:03 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6021:26 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6021:27 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6021:28 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
Index 6023 AI Acc Samples (Real32)
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6023:0 | AI Acc Samples (Real32) | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6023:01 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6023:02 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6023:03 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6023:26 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6023:27 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6023:28 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
Index 6030 AI Gyro Inputs
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6030:0 | AI Gyro Inputs | 
 | UINT8 | RO | 0x14 (20dec) | 
| 6030:09 | Self test status | 
 | BIT2 | RO | 0x00 (0dec) | 
| 6030:0B | Slope detected | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6030:0E | Sync error | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6030:0F | TxPDO State | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6030:10 | TxPDO Toggle | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6030:12 | Value | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6030:13 | Value (Real32) | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6030:14 | Input Cycle Counter | 
 | UINT16 | RO | 0x0000 (0dec) | 
Index 6031 AI Gyro Samples
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6031:0 | AI Gyro Samples | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6031:01 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6031:02 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6031:03 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6031:26 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6031:27 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6031:28 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
Index 6033 AI Gyro Samples (Real32)
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6033:0 | AI Gyro Samples (Real32) | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6033:01 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6033:02 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6033:03 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6033:26 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6033:27 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6033:28 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
Index 6040 AI Gyro Inputs
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6040:0 | AI Gyro Inputs | 
 | UINT8 | RO | 0x14 (20dec) | 
| 6040:09 | Self test status | 
 | BIT2 | RO | 0x00 (0dec) | 
| 6040:0B | Slope detected | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6040:0E | Sync error | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6040:0F | TxPDO State | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6040:10 | TxPDO Toggle | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6040:12 | Value | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6040:13 | Value (Real32) | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6040:14 | Input Cycle Counter | 
 | UINT16 | RO | 0x0000 (0dec) | 
Index 6041 AI Gyro Samples
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6041:0 | AI Gyro Samples | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6041:01 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6041:02 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6041:03 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6041:26 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6041:27 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6041:28 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
Index 6043 AI Gyro Samples (Real32)
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6043:0 | AI Gyro Samples (Real32) | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6043:01 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6043:02 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6043:03 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | …s | 
| 6043:26 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6043:27 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6043:28 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
Index 6050 AI Gyro Inputs
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6050:0 | AI Gyro Inputs | 
 | UINT8 | RO | 0x14 (20dec) | 
| 6050:09 | Self test status | 
 | BIT2 | RO | 0x00 (0dec) | 
| 6050:0B | Slope detected | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6050:0E | Sync error | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6050:0F | TxPDO State | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6050:10 | TxPDO Toggle | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6050:12 | Value | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6050:13 | Value (Real32) | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6050:14 | Input Cycle Counter | 
 | UINT16 | RO | 0x0000 (0dec) | 
Index 6051 AI Gyro Samples
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6051:0 | AI Gyro Samples | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6051:01 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6051:02 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6051:03 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6051:26 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6051:27 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6051:28 | Sample | 
 | INT32 | RO | 0x00000000 (0dec) | 
Index 6053 AI Gyro Samples (Real32)
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6053:0 | AI Gyro Samples (Real32) | 
 | UINT8 | RO | 0x28 (40dec) | 
| 6053:01 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6053:02 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6053:03 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| … | … | … | … | … | … | 
| 6053:26 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6053:27 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
| 6053:28 | Sample | 
 | REAL32 | RO | 0x00000000 (0dec) | 
Index 6060 AI Temp Inputs
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 6060:0 | AI Temp Inputs | 
 | UINT8 | RO | 0x13 (19dec) | 
| 6060:0E | Sync error | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6060:0F | TxPDO State | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6060:10 | TxPDO Toggle | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 6060:12 | Value | 
 | INT32 | RO | 0x00000000 (0dec) | 
| 6060:13 | Value (Real32) | 
 | REAL32 | RO | 0x00000000 (0dec) | 
Index 7070 DIG Outputs Ch.1
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| 7070:0 | DIG Outputs Ch.1 | 
 | UINT8 | RO | 0x03 (3dec) | 
| 7070:01 | LED 1 | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 7070:02 | LED 2 | 
 | BOOLEAN | RO | 0x00 (0dec) | 
| 7070:03 | LED 3 | 
 | BOOLEAN | RO | 0x00 (0dec) | 
Index F000 Modular Device Profile
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| F000:0 | Modular Device Profile | General information for the Modular Device Profile | UINT8 | RO | 0x02 (2dec) | 
| F000:01 | Index distance | Index distance of the objects of the individual channels | UINT16 | RO | 0x0010 (16dec) | 
| F000:02 | Maximum number of modules | Number of channels | UINT16 | RO | 0x0008 (8dec) | 
Index F008 Code word
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| F008:0 | Code word | 
 | UINT32 | RW | 0x00000000 (0dec) | 
Index F010 Module Profile List
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| F010:0 | Module Profile List | 
 | UINT8 | RO | 0x08 (8dec) | 
| F010:01 | SubIndex 001 | 
 | UINT32 | RO | 0x0000012C (300dec) | 
| F010:02 | SubIndex 002 | 
 | UINT32 | RO | 0x0000012C (300dec) | 
| F010:03 | SubIndex 003 | 
 | UINT32 | RO | 0x0000012C (300dec) | 
| F010:04 | SubIndex 004 | 
 | UINT32 | RO | 0x0000012C (300dec) | 
| F010:05 | SubIndex 005 | 
 | UINT32 | RO | 0x0000012C (300dec) | 
| F010:06 | SubIndex 006 | 
 | UINT32 | RO | 0x0000012C (300dec) | 
| F010:07 | SubIndex 007 | 
 | UINT32 | RO | 0x0000012C (300dec) | 
| F010:08 | SubIndex 008 | 
 | UINT32 | RO | 0x00000118 (280dec) | 
Index F912 Filter info
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| F912:0 | Filter info | 
 | UINT8 | RO | 0x07 (7dec) | 
| F912:01 | Info header | 
 | OCTET-STRING[8] | RO | {0} | 
| F912:02 | Filter 1 | 
 | OCTET-STRING[30] | RO | {0} | 
| F912:03 | Filter 2 | 
 | OCTET-STRING[30] | RO | {0} | 
| F912:04 | Filter 3 | 
 | OCTET-STRING[30] | RO | {0} | 
| F912:05 | Filter 4 | 
 | OCTET-STRING[30] | RO | {0} | 
| F912:06 | Filter 5 | 
 | OCTET-STRING[30] | RO | {0} | 
| F912:07 | Filter 6 | 
 | OCTET-STRING[30] | RO | {0} | 
Index FB10 CMD Command
| Index (hex) | Name | Meaning | Data type | Flags | Default | 
|---|---|---|---|---|---|
| FB10:0 | CMD Command | 
 | UINT8 | RO | 0x03 (3dec) | 
| FB10:01 | Request | 
 | OCTET-STRING[6] | RW | {0} | 
| FB10:02 | Status | 
 | UINT8 | RO | 0x00 (0dec) | 
| FB10:03 | Response | 
 | OCTET-STRING[6] | RO | {0} |