Technical data
All values are typical values over the entire temperature range, unless stated otherwise.
Supply voltages | |
|---|---|
Connection | Input: M8 connector, 4-pin Downstream connection: M8 socket, 4-pin, black |
|
US nominal voltage |
24 VDC (-15 % / +20 %) |
US sum current: IS,sum | max. 4 A |
Current consumption from US | 120 mA + IEPE supply current IEXCITE |
Rated voltage UP | 24 VDC (-15 % / +20 %) |
UP sum current: IP,sum | max. 4 A |
Current consumption from UP | None. UP is only forwarded. |
IEPE | |
|---|---|
Number of inputs | 2 |
Connection | 2 x M8 socket, four-pin, screwable, shielded |
Signal voltage | IEPE constant current supply and acquisition of modulated AC voltage |
Sensor state monitoring | yes, through monitoring of the bias voltage |
Measuring range | preset ±5 V up to 25 kHz, ±250 mV up to 10 Hz |
Input filter cut-off frequency | analog parameterizable 5th order low-pass filter up to 25 kHz, typically 0.05 Hz high-pass filter |
Measurement uncertainty | < ±0.5 % (DC, relative to full scale value) See chapter Measurement error/measurement deviation/measurement uncertainty, output uncertainty. |
Resolution | 16 bits (including sign) |
Conversion time | 20 μs (max. 50 kSamples/s) |
Supply current IEXCITE | 2 / 4 / 8 mA (separately adjustable for both channels) from the control voltage US |
Special features | automatic anti-aliasing function, wire break detection |
Housing data | |
|---|---|
Dimensions W x H x D | 30 mm x 126 mm x 26.5 mm (without connectors) |
Weight | approx. 165 g |
Installation position | variable |
|
Material |
PA6 (polyamide) |
Environmental conditions | |
|---|---|
Ambient temperature during operation | -25 … +60 °C |
Ambient temperature during storage | -40 … +85 °C |
Vibration resistance, shock resistance | conforms to EN 60068-2-6 / EN 60068-2-27 |
EMC immunity / emission | conforms to EN 61000-6-2 / EN 61000-6-4 |
Protection class | IP65, IP66, IP67 (conforms to EN 60529) |
Approvals/markings | |
|---|---|
Approvals/markings *) | CE, cURus |
*) Real applicable approvals/markings see type plate on the side (product marking).
Additional tests
The devices have undergone the following additional tests:
Test | Explanation |
|---|---|
Vibration | 10 frequency sweeps in 3 axes |
5 Hz < f < 60 Hz displacement 0.35 mm, constant amplitude | |
60.1 Hz < f < 500 Hz acceleration 5 g, constant amplitude | |
Shocks | 1000 shocks in each direction, in 3 axes |
35 g, 11 ms |