EP31x4-x002 - Object overview
![]()  | EtherCAT XML Device Description The presentation matches that of the EtherCAT XML Device Description.  | 
Index (hex)  | Name  | Flags  | Default value  | |
|---|---|---|---|---|
Device type  | RO  | 0x012C1389 (19665801dec)  | ||
Device name  | RO  | EP3174-0002  | ||
Hardware version  | RO  | -  | ||
Software version  | RO  | -  | ||
Subindex  | Restore default parameters  | RO  | 0x01 (1dec)  | |
1011:01  | SubIndex 001  | RW  | 0x00000000 (0dec)  | |
Subindex  | Identity  | RO  | 0x04 (4dec)  | |
1018:01  | Vendor ID  | RO  | 0x00000002 (2dec)  | |
1018:02  | Product code  | RO  | 0x0C664052 (208027730dec)  | |
1018:03  | Revision  | RO  | 0x00000000 (0dec)  | |
1018:04  | Serial number  | RO  | 0x00000000 (0dec)  | |
Subindex  | Backup parameter handling  | RO  | 0x01 (1dec)  | |
10F00:01  | Checksum  | RO  | 0x00000000 (0dec)  | |
Subindex  | AI TxPDO-Par Standard Ch. 1  | RO  | 0x06 (6dec)  | |
1800:06  | Exclude TxPDOs  | RO  | 01 1A  | |
Subindex  | AI TxPDO-Par-Compact Ch.1  | RO  | 0x06 (6dec)  | |
1801:06  | Exclude TxPDOs  | RO  | 00 1A  | |
Subindex  | AI TxPDO-Par Standard Ch.2  | RO  | 0x06 (6dec)  | |
1802:06  | Exclude TxPDOs  | RO  | 03 1A  | |
Subindex  | AI TxPDO-Par Compact Ch.2  | RO  | 0x06 (6dec)  | |
1803:06  | Exclude TxPDOs  | RO  | 02 1A  | |
Subindex  | AI TxPDO-Par Standard Ch.3  | RO  | 0x06 (6dec)  | |
1804:06  | Exclude TxPDOs  | RO  | 05 1A  | |
Subindex  | AI TxPDO-Par Compact Ch.3  | RO  | 0x06 (6dec)  | |
1805:06  | Exclude TxPDOs  | RO  | 04 1A  | |
Subindex  | AI TxPDO-Par Standard Ch.4  | RO  | 0x06 (6dec)  | |
1806:06  | Exclude TxPDOs  | RO  | 07 1A  | |
Subindex  | AI TxPDO-Par Compact Ch.4  | RO  | 0x06 (6dec)  | |
1807:06  | Exclude TxPDOs  | RO  | 06 1A  | |
Index (hex)  | Name  | Flags  | Default value  | |
Subindex  | AI TxPDO-Map Standard Ch.1  | RO  | 0x0B (11dec)  | |
1A00:01  | Subindex 001  | RO  | 0x6000:01, 1  | |
1A00:02  | Subindex 002  | RO  | 0x6000:02, 1  | |
1A00:03  | Subindex 003  | RO  | 0x6000:03, 2  | |
1A00:04  | Subindex 004  | RO  | 0x6000:05, 2  | |
1A00:05  | Subindex 005  | RO  | 0x6000:07, 1  | |
1A00:06  | Subindex 006  | RO  | 0x0000:00, 1  | |
1A00:07  | Subindex 007  | RO  | 0x0000:00, 5  | |
1A00:08  | Subindex 008  | RO  | 0x6000:0E, 1  | |
1A00:09  | Subindex 009  | RO  | 0x6000:0F, 1  | |
1A00:0A  | Subindex 010  | RO  | 0x6000:10, 1  | |
1A00:0B  | Subindex 011  | RO  | 0x6000:11, 16  | |
Subindex  | AI TxPDO-Map Compact Ch.1  | RO  | 0x01 (1dec)  | |
1A01:01  | SubIndex 001  | RO  | 0x6000:11, 16  | |
Subindex  | AI TxPDO-Map Standard Ch.2  | RO  | 0x0B (11dec)  | |
1A02:01  | SubIndex 001  | RO  | 0x6010:01, 1  | |
1A02:02  | SubIndex 002  | RO  | 0x6010:02, 1  | |
1A02:03  | SubIndex 003  | RO  | 0x6010:03, 2  | |
1A02:04  | SubIndex 004  | RO  | 0x6010:05, 2  | |
1A02:05  | SubIndex 005  | RO  | 0x6010:07, 1  | |
1A02:06  | SubIndex 006  | RO  | 0x0000:00, 1  | |
1A02:07  | SubIndex 007  | RO  | 0x0000:00, 6  | |
1A02:08  | SubIndex 008  | RO  | 0x1802:07, 1  | |
1A02:09  | SubIndex 009  | RO  | 0x1802:09, 1  | |
1A02:0A  | SubIndex 010  | RO  | 0x6010:10, 1  | |
1A02:0B  | SubIndex 011  | RO  | 0x6010:11, 16  | |
Subindex  | AI TxPDO-Map Compact Ch.2  | RO  | 0x01 (1dec)  | |
1A03:01  | SubIndex 001  | RO  | 0x6010:11, 16  | |
Subindex  | AI TxPDO-Map Standard Ch.3  | RO  | 0x0B (11dec)  | |
1A04:01  | SubIndex 001  | RO  | 0x6020:01, 1  | |
1A04:02  | SubIndex 002  | RO  | 0x6020:02, 1  | |
1A04:03  | SubIndex 003  | RO  | 0x6020:03, 2  | |
1A04:04  | SubIndex 004  | RO  | 0x6020:05, 2  | |
1A04:05  | SubIndex 005  | RO  | 0x6020:07, 1  | |
1A04:06  | SubIndex 006  | RO  | 0x0000:00, 1  | |
1A04:07  | SubIndex 007  | RO  | 0x0000:00, 5  | |
1A04:08  | SubIndex 008  | RO  | 0x6020:0E, 1  | |
1A04:09  | SubIndex 009  | RO  | 0x6020:0F, 1  | |
1A04:0A  | SubIndex 010  | RO  | 0x6020:10, 1  | |
1A04:0B  | SubIndex 011  | RO  | 0x6020:11, 16  | |
Subindex  | AI TxPDO-Map Compact Ch.3  | RO  | 0x01 (1dec)  | |
1A05:01  | SubIndex 001  | RO  | 0x6020:11, 16  | |
Subindex  | AI TxPDO-Map Standard Ch.4  | RO  | 0x0B (11dec)  | |
1A06:01  | SubIndex 001  | RO  | 0x6030:01, 1  | |
1A06:02  | SubIndex 002  | RO  | 0x6030:02, 1  | |
1A06:03  | SubIndex 003  | RO  | 0x6030:03, 2  | |
1A06:04  | SubIndex 004  | RO  | 0x6030:05, 2  | |
1A06:05  | SubIndex 005  | RO  | 0x6030:07, 1  | |
1A06:06  | SubIndex 006  | RO  | 0x0000:00, 1  | |
1A06:07  | SubIndex 007  | RO  | 0x0000:00, 5  | |
1A06:08  | SubIndex 008  | RO  | 0x6030:0E, 1  | |
1A06:09  | SubIndex 009  | RO  | 0x6030:0F, 1  | |
1A06:0A  | SubIndex 010  | RO  | 0x6030:10, 1  | |
1A06:0B  | SubIndex 011  | RO  | 0x6030:11, 16  | |
Subindex  | AI TxPDO-Map Compact Ch.4  | RO  | 0x01 (1dec)  | |
1A07:01  | SubIndex 001  | RO  | 0x6030:11, 16  | |
Subindex  | Sync manager type  | RO  | 0x04 (4dec)  | |
1C00:01  | SubIndex 001  | RO  | 0x01 (1dec)  | |
1C00:02  | SubIndex 002  | RO  | 0x02 (2dec)  | |
1C00:03  | SubIndex 003  | RO  | 0x03 (3dec)  | |
1C00:04  | SubIndex 004  | RO  | 0x04 (4dec)  | |
Subindex  | RxPDO assign  | RW  | 0x00 (0dec)  | |
Subindex  | TxPDO assign  | RW  | 0x04 (4dec)  | |
1C13:01  | SubIndex 001  | RW  | 0x1A00 (6656dec)  | |
1C13:02  | SubIndex 002  | RW  | 0x1A02 (6658dec)  | |
1C13:03  | SubIndex 003  | RW  | 0x1A04 (6660dec)  | |
1C13:04  | SubIndex 004  | RW  | 0x1A06 (6662dec)  | |
Subindex  | SM output parameter  | RO  | 0x20 (32dec)  | |
1C33:01  | Sync mode  | RW  | 0x0022 (34dec)  | |
1C33:02  | Cycle time  | RW  | 0x000F4240 (1000000dec)  | |
1C33:03  | Shift time  | RO  | 0x00001388 (5000dec)  | |
1C33:04  | Sync modes supported  | RO  | 0xC00B (49163dec)  | |
1C33:05  | Minimum cycle time  | RO  | 0x0003D090 (250000dec)  | |
1C33:06  | Calc and copy time  | RO  | 0x00001388 (5000dec)  | |
1C33:07  | Minimum delay time  | RO  | 0x00000000 (0dec)  | |
1C33:08  | Command  | RW  | 0x0000 (0dec)  | |
1C33:09  | Maximum Delay time  | RO  | 0x00001388 (5000dec)  | |
1C33:0B  | SM event missed counter  | RO  | 0x0000 (0dec)  | |
1C33:0C  | Cycle exceeded counter  | RO  | 0x0000 (0dec)  | |
1C33:0D  | Shift too short counter  | RO  | 0x0000 (0dec)  | |
1C33:20  | Sync error  | RO  | 0x00 (0dec)  | |
Subindex  | AI Inputs  | RO  | 0x11 (17dec)  | |
6000:01  | Underrange  | RO  | 0x00 (0dec)  | |
6000:02  | Overrange  | RO  | 0x00 (0dec)  | |
6000:03  | Limit 1  | RO  | -  | |
6000:05  | Limit 2  | RO  | -  | |
6000:07  | Error  | RO  | 0x00 (0dec)  | |
6000:0E  | Sync error  | RO  | 0x00 (0dec)  | |
6000:0F  | TxPDO State  | RO  | 0x00 (0dec)  | |
6000:10  | TxPDO Toggle  | RO  | 0x00 (0dec)  | |
6000:11  | Value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Inputs  | RO  | 0x11 (17dec)  | |
6010:01  | Underrange  | RO  | 0x00 (0dec)  | |
6010:02  | Overrange  | RO  | 0x00 (0dec)  | |
6010:03  | Limit 1  | RO  | -  | |
6010:05  | Limit 2  | RO  | -  | |
6010:07  | Error  | RO  | 0x00 (0dec)  | |
6010:0F  | TxPDO State  | RO  | 0x00 (0dec)  | |
6010:10  | TxPDO Toggle  | RO  | 0x00 (0dec)  | |
6010:11  | Value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Inputs  | RO  | 0x11 (17dec)  | |
6020:01  | Underrange  | RO  | 0x00 (0dec)  | |
6020:02  | Overrange  | RO  | 0x00 (0dec)  | |
6020:03  | Limit 1  | RO  | -  | |
6020:05  | Limit 2  | RO  | -  | |
6020:07  | Error  | RO  | 0x00 (0dec)  | |
6020:0E  | Sync error  | RO  | 0x00 (0dec)  | |
6020:0F  | TxPDO State  | RO  | 0x00 (0dec)  | |
6020:10  | TxPDO Toggle  | RO  | 0x00 (0dec)  | |
6020:11  | Value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Inputs  | RO  | 0x11 (17dec)  | |
6030:01  | Underrange  | RO  | 0x00 (0dec)  | |
6030:02  | Overrange  | RO  | 0x00 (0dec)  | |
6030:03  | Limit 1  | RO  | -  | |
6030:05  | Limit 2  | RO  | -  | |
6030:07  | Error  | RO  | 0x00 (0dec)  | |
6030:0E  | Sync error  | RO  | 0x00 (0dec)  | |
6030:0F  | TxPDO State  | RO  | 0x00 (0dec)  | |
6030:10  | TxPDO Toggle  | RO  | 0x00 (0dec)  | |
6030:11  | Value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Settings  | RW  | 0x18 (24dec)  | |
8000:01  | Enable user scale  | RW  | 0x00 (0dec)  | |
8000:02  | Presentation  | RW  | 0x00 (0dec)  | |
8000:05  | Siemens bits  | RW  | 0x00 (0dec)  | |
8000:06  | Enable filter  | RW  | 0x01 (1dec)  | |
8000:07  | Enable limit 1  | RW  | 0x00 (0dec)  | |
8000:08  | Enable limit 2  | RW  | 0x00 (0dec)  | |
8000:0A  | Enable user calibration  | RW  | 0x00 (0dec)  | |
8000:0B  | Enable vendor calibration  | RW  | 0x01 (1dec)  | |
8000:0E  | Swap limit bits  | RW  | 0x00 (0dec)  | |
8000:11  | User scale offset  | RW  | 0x0000 (0dec)  | |
8000:12  | User scale gain  | RW  | 0x00010000 (65536dec)  | |
8000:13  | Limit 1  | RW  | 0x0000 (0dec)  | |
8000:14  | Limit 2  | RW  | 0x0000 (0dec)  | |
8000:15  | Filter settings  | RW  | 0x0000 (0dec)  | |
8000:17  | User calibration offset  | RW  | 0x0000 (0dec)  | |
8000:18  | User calibration gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | AI Internal data  | RO  | 0x01 (1dec)  | |
800E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Vendor data  | RW  | 0x06 (6dec)  | |
800F:01  | R0 offset  | RW  | 0x0000 (0dec)  | |
800F:02  | R0 gain  | RW  | 0x4000 (16384dec)  | |
800F:03  | R1 offset  | RW  | 0x0000 (0dec)  | |
800F:04  | R1 gain  | RW  | 0x4000 (16384dec)  | |
800F:05  | R2 offset  | RW  | 0x0000 (0dec)  | |
800F:06  | R2 gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | AI Settings  | RW  | 0x18 (24dec)  | |
8010:01  | Enable user scale  | RW  | 0x00 (0dec)  | |
8010:02  | Presentation  | RW  | 0x00 (0dec)  | |
8010:05  | Siemens bits  | RW  | 0x00 (0dec)  | |
8010:06  | Enable filter  | RW  | 0x00 (0dec)  | |
8010:07  | Enable limit 1  | RW  | 0x00 (0dec)  | |
8010:08  | Enable limit 2  | RW  | 0x00 (0dec)  | |
8010:0A  | Enable user calibration  | RW  | 0x00 (0dec)  | |
8010:0B  | Enable vendor calibration  | RW  | 0x01 (1dec)  | |
8010:0E  | Swap limit bits  | RW  | 0x00 (0dec)  | |
8010:11  | User scale offset  | RW  | 0x0000 (0dec)  | |
8010:12  | User scale gain  | RW  | 0x00010000 (65536dec)  | |
8010:13  | Limit 1  | RW  | 0x0000 (0dec)  | |
8010:14  | Limit 2  | RW  | 0x0000 (0dec)  | |
8010:15  | Filter settings  | RW  | 0x0000 (0dec)  | |
8010:17  | User calibration offset  | RW  | 0x0000 (0dec)  | |
8010:18  | User calibration gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | AI Internal data  | RO  | 0x01 (1dec)  | |
801E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Vendor data  | RW  | 0x06 (6dec)  | |
801F:01  | R0 offset  | RW  | 0x0000 (0dec)  | |
801F:02  | R0 gain  | RW  | 0x4000 (16384dec)  | |
801F:03  | R1 offset  | RW  | 0x0000 (0dec)  | |
801F:04  | R1 gain  | RW  | 0x4000 (16384dec)  | |
801F:05  | R2 offset  | RW  | 0x0000 (0dec)  | |
801F:06  | R2 gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | AI Settings  | RW  | 0x18 (24dec)  | |
8020:01  | Enable user scale  | RW  | 0x00 (0dec)  | |
8020:02  | Presentation  | RW  | 0x00 (0dec)  | |
8020:05  | Siemens bits  | RW  | 0x00 (0dec)  | |
8020:06  | Enable filter  | RW  | 0x01 (1dec)  | |
8020:07  | Enable limit 1  | RW  | 0x00 (0dec)  | |
8020:08  | Enable limit 2  | RW  | 0x00 (0dec)  | |
8020:0A  | Enable user calibration  | RW  | 0x00 (0dec)  | |
8020:0B  | Enable vendor calibration  | RW  | 0x01 (1dec)  | |
8020:0E  | Swap limit bits  | RW  | 0x00 (0dec)  | |
8020:11  | User scale offset  | RW  | 0x0000 (0dec)  | |
8020:12  | User scale gain  | RW  | 0x00010000 (65536dec)  | |
8020:13  | Limit 1  | RW  | 0x0000 (0dec)  | |
8020:14  | Limit 2  | RW  | 0x0000 (0dec)  | |
8020:15  | Filter settings  | RW  | 0x0000 (0dec)  | |
8020:17  | User calibration offset  | RW  | 0x0000 (0dec)  | |
8020:18  | User calibration gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | AI Internal data  | RO  | 0x01 (1dec)  | |
802E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Vendor data  | RW  | 0x06 (6dec)  | |
802F:01  | R0 offset  | RW  | 0x0000 (0dec)  | |
802F:02  | R0 gain  | RW  | 0x4000 (16384dec)  | |
802F:03  | R1 offset  | RW  | 0x0000 (0dec)  | |
802F:04  | R1 gain  | RW  | 0x4000 (16384dec)  | |
802F:05  | R2 offset  | RW  | 0x0000 (0dec)  | |
802F:06  | R2 gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | AI Settings  | RW  | 0x18 (24dec)  | |
8030:01  | Enable user scale  | RW  | 0x00 (0dec)  | |
8030:02  | Presentation  | RW  | 0x00 (0dec)  | |
8030:05  | Siemens bits  | RW  | 0x00 (0dec)  | |
8030:06  | Enable filter  | RW  | 0x01 (1dec)  | |
8030:07  | Enable limit 1  | RW  | 0x00 (0dec)  | |
8030:08  | Enable limit 2  | RW  | 0x00 (0dec)  | |
8030:0A  | Enable user calibration  | RW  | 0x00 (0dec)  | |
8030:0B  | Enable vendor calibration  | RW  | 0x01 (1dec)  | |
8030:0E  | Swap limit bits  | RW  | 0x00 (0dec)  | |
8030:11  | User scale offset  | RW  | 0x0000 (0dec)  | |
8030:12  | User scale gain  | RW  | 0x00010000 (65536dec)  | |
8030:13  | Limit 1  | RW  | 0x0000 (0dec)  | |
8030:14  | Limit 2  | RW  | 0x0000 (0dec)  | |
8030:15  | Filter settings  | RW  | 0x0000 (0dec)  | |
8030:17  | User calibration offset  | RW  | 0x0000 (0dec)  | |
8030:18  | User calibration gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | AI Internal data  | RO  | 0x01 (1dec)  | |
803E:01  | ADC raw value  | RO  | 0x0000 (0dec)  | |
Subindex  | AI Vendor data  | RW  | 0x06 (6dec)  | |
803F:01  | R0 offset  | RW  | 0x0000 (0dec)  | |
803F:02  | R0 gain  | RW  | 0x4000 (16384dec)  | |
803F:03  | R1 offset  | RW  | 0x0000 (0dec)  | |
803F:04  | R1 gain  | RW  | 0x4000 (16384dec)  | |
803F:05  | R2 offset  | RW  | 0x0000 (0dec)  | |
803F:06  | R2 gain  | RW  | 0x4000 (16384dec)  | |
Subindex  | Modular device profile  | RO  | 0x02 (2dec)  | |
F000:01  | Module index distance  | RO  | 0x0010 (16dec)  | |
F000:02  | Maximum number of modules  | RO  | 0x0004 (4dec)  | |
Code word  | RW  | 0x00000000 (0dec)  | ||
Subindex  | Module list  | RW  | 0x04 (4dec)  | |
F010:01  | SubIndex 001  | RW  | 0x0000012C (300dec)  | |
F010:02  | SubIndex 002  | RW  | 0x0000012C (300dec)  | |
F010:03  | SubIndex 003  | RW  | 0x0000012C (300dec)  | |
F010:04  | SubIndex 004  | RW  | 0x0000012C (300dec)  | |
Subindex  | AI Range Settings (new modules)  | RW  | 0x04 (4dec)  | |
F800:01  | Input type Ch1  | RW  | 0x0000 (0dec)  | |
F800:02  | Input type Ch2  | RW  | 0x0000 (0dec)  | |
F800:03  | Input type Ch3  | RW  | 0x0000 (0dec)  | |
F800:04  | Input type Ch4  | RW  | 0x0000 (0dec)  | |
F800:05  | Enable Filter Settings Per Channel  | RW  | -  | |
Legend
Flags:
RO (Read Only): this object can only be read
RW (Read/Write): this object can be read and written to