D-Sub sockets, 25-pin (EP2817-0008 only)
Pin assignment
| Pin | Function | 
|---|---|
| 1 | Channel 1, Output 1 | 
| 2 | Channel 1, Output 3 | 
| 3 | Channel 1, Output 5 | 
| 4 | Channel 1, Output 7 | 
| 5 | Channel 2, Output 1 | 
| 6 | Channel 2, Output 3 | 
| 7 | Channel 2, Output 5 | 
| 8 | Channel 2, Output 7 | 
| 9 | Channel 3, Output 1 | 
| 10 | Channel 3, Output 3 | 
| 11 | Channel 3, Output 5 | 
| 12 | Channel 3, Output 7 | 
| 13 | GNDP | 
| 14 | Channel 1, Output 2 | 
| 15 | Channel 1, Output 4 | 
| 16 | Channel 1, Output 6 | 
| 17 | Channel 1, Output 8 | 
| 18 | Channel 2, Output 2 | 
| 19 | Channel 2, Output 4 | 
| 20 | Channel 2, Output 6 | 
| 21 | Channel 2, Output 8 | 
| 22 | Channel 3, Output 2 | 
| 23 | Channel 3, Output 4 | 
| 24 | Channel 3, Output 6 | 
| 25 | Channel 3, Output 8 |