Configuration data vendor-specific

Index 801F DRV Vendor data Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

801F:0

DRV Vendor data Ch.1

 

UINT8

RO

0x18 (24dec)

801F:11

Amplifier peak current

Peak current of the amplifier (RMS value).

Unit: mA

UINT32

RW

1)

801F:12

Amplifier rated current

Nominal current of the amplifier (RMS value).

Unit: mA

UINT32

RW

2)

801F:14

Amplifier overcurrent threshold

Threshold value for short circuit detection, maximum phase current (peak value).

Unit: mA

UINT32

RW

3)

801F:15

Max rotary field frequency

Maximum rotary field frequency.

Unit: Hz

UINT16

RW

0x0257 (599dec)

801F:16

Amplifier peak current with fan

Amplifier peak current with fan (RMS value).

Unit: mA

UINT32

RW

4)

801F:17

Amplifier rated current with fan

Amplifier nominal current with fan (RMS value).

Unit: mA

UINT32

RW

5)

801F:18

Vendor feature bits

 

UINT32

RW

0x00000000 (0dec)

1) The default value of "Amplifier peak current" varies depending on the product:

  • ELM7211: 0x00002328 (9000dec)
  • ELM7212: 0x00002328 (9000dec)
  • ELM7221: 0x00003E80 (16000dec)
  • ELM7222: 0x00003E80 (16000dec)
  • ELM7231: 0x00007530 (30000dec)

2) The default value of "Amplifier rated current" varies depending on the product:

  • ELM7211: 0x00001194 (4500dec)
  • ELM7212: 0x00001194 (4500dec)
  • ELM7221: 0x00001F40 (8000dec)
  • ELM7222: 0x00001F40 (8000dec)
  • ELM7231: 0x00003E80 (16000dec)

3) The default value of "Amplifier overcurrent threshold" varies depending on the product:

  • ELM7211: 0x00006D60 (28000dec)
  • ELM7212: 0x00006D60 (28000dec)
  • ELM7221: 0x00006D60 (28000dec)
  • ELM7222: 0x00006D60 (28000dec)
  • ELM7231: 0x0000C350 (50000dec)

4) The default value of "Amplifier peak current with fan" varies depending on the product:

  • ELM7211: 0x00002328 (9000dec)
  • ELM7212: 0x00002328 (9000dec)
  • ELM7221: 0x00003E80 (16000dec)
  • ELM7222: 0x00003E80 (16000dec)
  • ELM7231: 0x00007530 (30000dec)

5) The default value of "Amplifier rated current with fan" varies depending on the product:

  • ELM7211: 0x00001194 (4500dec)
  • ELM7212: 0x00001194 (4500dec)
  • ELM7221: 0x00001F40 (8000dec)
  • ELM7222: 0x00001F40 (8000dec)
  • ELM7231: 0x00003E80 (16000dec)

Index 811F DRV Vendor data Ch.2 (ELM72x2 only)

Index (hex)

Name

Meaning

Data type

Flags

Default

811F:0

DRV Vendor data Ch.2

 

UINT8

RO

0x18 (24dec)

811F:11

Amplifier peak current

Peak current of the amplifier (RMS value).

Unit: mA

UINT32

RW

1)

811F:12

Amplifier rated current

Nominal current of the amplifier (RMS value).

Unit: mA

UINT32

RW

2)

811F:14

Amplifier overcurrent threshold

Threshold value for short circuit detection, maximum phase current (peak value).

Unit: mA

UINT32

RW

3)

811F:15

Max rotary field frequency

Maximum rotary field frequency.

Unit: Hz

UINT16

RW

0x0257 (599dec)

811F:16

Amplifier peak current with fan

Amplifier peak current with fan (RMS value).

Unit: mA

UINT32

RW

4)

811F:17

Amplifier rated current with fan

Amplifier nominal current with fan (RMS value).

Unit: mA

UINT32

RW

5)

811F:18

Vendor feature bits

 

UINT32

RW

0x00000000 (0dec)

1) The default value of "Amplifier peak current" varies depending on the product:

  • ELM7211: 0x00002328 (9000dec)
  • ELM7212: 0x00002328 (9000dec)
  • ELM7221: 0x00003E80 (16000dec)
  • ELM7222: 0x00003E80 (16000dec)
  • ELM7231: 0x00007530 (30000dec)

2) The default value of "Amplifier rated current" varies depending on the product:

  • ELM7211: 0x00001194 (4500dec)
  • ELM7212: 0x00001194 (4500dec)
  • ELM7221: 0x00001F40 (8000dec)
  • ELM7222: 0x00001F40 (8000dec)
  • ELM7231: 0x00003E80 (16000dec)

3) The default value of "Amplifier overcurrent threshold" varies depending on the product:

  • ELM7211: 0x00006D60 (28000dec)
  • ELM7212: 0x00006D60 (28000dec)
  • ELM7221: 0x00006D60 (28000dec)
  • ELM7222: 0x00006D60 (28000dec)
  • ELM7231: 0x0000C350 (50000dec)

4) The default value of "Amplifier peak current with fan" varies depending on the product:

  • ELM7211: 0x00002328 (9000dec)
  • ELM7212: 0x00002328 (9000dec)
  • ELM7221: 0x00003E80 (16000dec)
  • ELM7222: 0x00003E80 (16000dec)
  • ELM7231: 0x00007530 (30000dec)

5) The default value of "Amplifier rated current with fan" varies depending on the product:

  • ELM7211: 0x00001194 (4500dec)
  • ELM7212: 0x00001194 (4500dec)
  • ELM7221: 0x00001F40 (8000dec)
  • ELM7222: 0x00001F40 (8000dec)
  • ELM7231: 0x00003E80 (16000dec)

Index FB13 DRV Key code

Index (hex)

Name

Meaning

Data type

Flags

Default

FB13:0

DRV Key code

 

UINT8

RO

0x01 (1dec)

FB13:01

Code

 

OCTET-STRING[32]

RW

{0}