Configuration data vendor-specific
Index 801F DRV Vendor data Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
801F:0 | DRV Vendor data Ch.1 |
| UINT8 | RO | 0x18 (24dec) |
801F:11 | Amplifier peak current | Peak current of the amplifier (RMS value). Unit: mA | UINT32 | RW | 1) |
801F:12 | Amplifier rated current | Nominal current of the amplifier (RMS value). Unit: mA | UINT32 | RW | 2) |
801F:14 | Amplifier overcurrent threshold | Threshold value for short circuit detection, maximum phase current (peak value). Unit: mA | UINT32 | RW | 3) |
801F:15 | Max rotary field frequency | Maximum rotary field frequency. Unit: Hz | UINT16 | RW | 0x0257 (599dec) |
801F:16 | Amplifier peak current with fan | Amplifier peak current with fan (RMS value). Unit: mA | UINT32 | RW | 4) |
801F:17 | Amplifier rated current with fan | Amplifier nominal current with fan (RMS value). Unit: mA | UINT32 | RW | 5) |
801F:18 | Vendor feature bits |
| UINT32 | RW | 0x00000000 (0dec) |
1) The default value of "Amplifier peak current" varies depending on the product:
2) The default value of "Amplifier rated current" varies depending on the product:
3) The default value of "Amplifier overcurrent threshold" varies depending on the product:
4) The default value of "Amplifier peak current with fan" varies depending on the product:
5) The default value of "Amplifier rated current with fan" varies depending on the product:
|
Index 811F DRV Vendor data Ch.2 (ELM72x2 only)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
811F:0 | DRV Vendor data Ch.2 |
| UINT8 | RO | 0x18 (24dec) |
811F:11 | Amplifier peak current | Peak current of the amplifier (RMS value). Unit: mA | UINT32 | RW | 1) |
811F:12 | Amplifier rated current | Nominal current of the amplifier (RMS value). Unit: mA | UINT32 | RW | 2) |
811F:14 | Amplifier overcurrent threshold | Threshold value for short circuit detection, maximum phase current (peak value). Unit: mA | UINT32 | RW | 3) |
811F:15 | Max rotary field frequency | Maximum rotary field frequency. Unit: Hz | UINT16 | RW | 0x0257 (599dec) |
811F:16 | Amplifier peak current with fan | Amplifier peak current with fan (RMS value). Unit: mA | UINT32 | RW | 4) |
811F:17 | Amplifier rated current with fan | Amplifier nominal current with fan (RMS value). Unit: mA | UINT32 | RW | 5) |
811F:18 | Vendor feature bits |
| UINT32 | RW | 0x00000000 (0dec) |
1) The default value of "Amplifier peak current" varies depending on the product:
2) The default value of "Amplifier rated current" varies depending on the product:
3) The default value of "Amplifier overcurrent threshold" varies depending on the product:
4) The default value of "Amplifier peak current with fan" varies depending on the product:
5) The default value of "Amplifier rated current with fan" varies depending on the product:
|
Index FB13 DRV Key code
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
FB13:0 | DRV Key code |
| UINT8 | RO | 0x01 (1dec) |
FB13:01 | Code |
| OCTET-STRING[32] | RW | {0} |