Standard objects

Index 1008 Device name

Index (hex)

Name

Meaning

Data type

Flags

Default

1008:0

Device name

Device name of the EtherCAT slave

STRING

RO

EL9501
or
EL9561

Index 100A Software version

Index (hex)

Name

Meaning

Data type

Flags

Default

100A:0

Software version

Firmware version of the EtherCAT slave

STRING

RO

00

Index 100B Bootloader version

Index (hex)

Name

Meaning

Data type

Flags

Default

100B:0

Bootloader version

Bootloader version

STRING

RO

n/a

Index 1018 Identity

Index (hex)

Name

Meaning

Data type

Flags

Default

1018:0

Identity

Information for identifying the slave

UINT8

RO

0x04 (4dec)

1018:01

Vendor ID

Vendor ID of the EtherCAT slave

UINT32

RO

0x00000002 (2dec)

1018:02

Product code

Product code of the EtherCAT slave

UINT32

RO

EL9501:
0x251D3052 (622669906dec)

EL9561:
0x25593052 (626602066dec)

1018:03

Revision

Revision number of the EtherCAT slave:

  • The Low Word (bit 0-15) indicates the special terminal number.
  • The High Word (bit 16-31) refers to the device description.

UINT32

RO

0x00000000 (0dec)

1018:04

Serial number

Serial number of the EtherCAT slave:

  • Low word
    • The low byte (bit 0-7) of the low word contains the year of production.
    • The high byte (bit 8-15) of the low word contains the week of production.
  • The high word (bit 16-31) is 0.

UINT32

RO

0x00000000 (0dec)

Index 10E2 Manufacturer-specific Identification Code

Index (hex)

Name

Meaning

Data type

Flags

Default

10E2:0

Manufacturer-specific Identification Code

Manufacturer-specific Identification Code

UINT8

RO

0x01 (1dec)

10E2:01

SubIndex 001

reserved

STRING

RO

 

Index 10F0 Backup parameter handling

Index (hex)

Name

Meaning

Data type

Flags

Default

10F0:0

Backup parameter handling

Information for standardized loading and saving of backup entries

UINT8

RO

0x01 (1dec)

10F0:01

Checksum

Checksum across all backup entries of the EtherCAT slave

UINT32

RO

0x00000000 (0dec)

Index 10F3 Diagnosis History

Index (hex)

Name

Meaning

Data type

Flags

Default

10F3:0

Diagnosis History

Maximum subindex

UINT8

RO

0x15 (21dec)

10F3:01

Maximum Messages

Maximum number of stored messages
A maximum of 16 messages can be stored

UINT8

RO

0x00 (0dec)

10F3:02

Newest Message

Subindex of the latest message

UINT8

RO

0x00 (0dec)

10F3:03

Newest Acknowledged Message

Subindex of the last confirmed message

UINT8

RW

0x00 (0dec)

10F3:04

New Messages Available

Indicates that a new message is available

BOOLEAN

RO

0x00 (0dec)

10F3:05

Flags

not used

UINT16

RW

0x0000 (0dec)

10F3:06

Diagnosis Message 001

Message 1

OCTET-STRING[24]

RO

{0}

…

…

….

…

…

…

10F3:15

Diagnosis Message 016

Message 16

OCTET-STRING[24]

RO

{0}

Index 10F8 Timestamp Object

Index (hex)

Name

Meaning

Data type

Flags

Default

10F8:0

Timestamp Object

Timestamp Object [ns]

For SM synchronous operation:
Time since power-on

For DC synchronous operation:
copy of the DC time

Time can be used by the device e.g. for timestamps of the DiagMessage

UINT64

RO

 

Index 1400 AO Output RxPDO-Par Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1400:0

AO Output RxPDO-Par Standard (INT16)

PDO Parameter RxPDO 1

UINT8

RO

0x06 (6dec)

1400:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 1.

OCTET-STRING[6]

RO

01 16 02 16 03 16

Index 1401 AO Output RxPDO-Par Compact (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1401:0

AO Output RxPDO-Par Compact (INT16)

PDO Parameter RxPDO 2

UINT8

RO

0x06 (6dec)

1401:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 2.

OCTET-STRING[6]

RO

00 16 02 16 03 16

Index 1402 AO Output RxPDO-Par Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1402:0

AO Output RxPDO-Par Standard (Real32)

PDO Parameter RxPDO 3

UINT8

RO

0x06 (6dec)

1402:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 3.

OCTET-STRING[6]

RO

00 16 01 16 03 16

Index 1403 AO Output RxPDO-Par Compact (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1403:0

AO Output RxPDO-Par Compact (Real32)

PDO Parameter RxPDO 4

UINT8

RO

0x06 (6dec)

1403:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 4.

OCTET-STRING[6]

RO

00 16 01 16 02 16

Index 1410 AO Complementary Limit High RxPDO-Par Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1410:0

AO Complementary Limit High RxPDO-Par Standard (INT16)

PDO Parameter RxPDO 17

UINT8

RO

0x06 (6dec)

1410:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 17.

OCTET-STRING[6]

RO

12 16 00 00 00 00

Index 1412 AO Complementary Limit High RxPDO-Par (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1412:0

AO Complementary Limit High RxPDO-Par Standard (Real32)

PDO Parameter RxPDO 19

UINT8

RO

0x06 (6dec)

1412:06

Exclude RxPDOs

Specifies the RxPDOs (index of RxPDO mapping objects) that must not be transferred together with RxPDO 19.

OCTET-STRING[6]

RO

10 16 00 00 00 00

Index 1600 AO Output RxPDO-Map Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1600:0

AO Output RxPDO-Map Standard (INT16)

PDO Mapping RxPDO 1

UINT8

RO

0x03 (3dec)

1600:01

SubIndex 001

1. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x15 (Output Interface))

UINT32

RO

0x7000:15, 16

1600:02

SubIndex 002

2. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x16 (Output Operation))

UINT32

RO

0x7000:16, 16

1600:03

SubIndex 003

3. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x11 (Value))

UINT32

RO

0x7000:11, 16

Index 1601 AO Output RxPDO-Map Compact (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1601:0

AO Output RxPDO-Map Compact (INT16)

PDO Mapping RxPDO 2

UINT8

RO

0x01 (1dec)

1601:01

SubIndex 001

1. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x11 (Value))

UINT32

RO

0x7000:11, 16

Index 1602 AO Output RxPDO-Map Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1602:0

AO Output RxPDO-Map Standard (Real32)

PDO Mapping RxPDO 3

UINT8

RO

0x03 (3dec)

1602:01

SubIndex 001

1. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x15 (Output Interface))

UINT32

RO

0x7000:15, 16

1602:02

SubIndex 002

2. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x16 (Output Operation))

UINT32

RO

0x7000:16, 16

1602:03

SubIndex 003

3. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x7000:13, 32

Index 1603 AO Output RxPDO-Map Compact (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1603:0

AO Output RxPDO-Map Compact (Real32)

PDO Mapping RxPDO 4

UINT8

RO

0x01 (1dec)

1603:01

SubIndex 001

1. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x7000:13, 32

Index 1604 AO Output RxPDO-Map Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1604:0

AO Output RxPDO-Map Cycle Counter

PDO Mapping RxPDO 5

UINT8

RO

0x01 (1dec)

1604:01

SubIndex 001

1. PDO Mapping entry (object 0x7000 (AO Output Outputs), entry 0x14 (Output Cycle Counter))

UINT32

RO

0x7000:14, 16

Index 1610 AO Complementary Limit High RxPDO-Map Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1610:0

AO Complementary Limit High RxPDO-Map Standard (INT16)

PDO Mapping RxPDO 17

UINT8

RO

0x01 (1dec)

1610:01

SubIndex 001

1. PDO Mapping entry (object 0x7010 (AO Complementary Limit High Outputs), entry 0x11 (Value))

UINT32

RO

0x7010:11, 16

Index 1612 AO Complementary Limit High RxPDO-Map Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1612:0

AO Complementary Limit High RxPDO-Map Standard (Real32)

PDO Mapping RxPDO 19

UINT8

RO

0x01 (1dec)

1612:01

SubIndex 001

1. PDO Mapping entry (object 0x7010 (AO Complementary Limit High Outputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x7010:13, 32

Index 1614 AO Complementary Limit High RxPDO-Map Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1614:0

AO Complementary Limit High RxPDO-Map Cycle Counter

PDO Mapping RxPDO 21

UINT8

RO

0x01 (1dec)

1614:01

SubIndex 001

1. PDO Mapping entry (object 0x7010 (AO Complementary Limit High Outputs), entry 0x14 (Output Cycle Counter))

UINT32

RO

0x7010:14, 16

Index 1830 AI Input Voltage TxPDO-Par Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1830:0

AI Input Voltage TxPDO-Par Standard (INT16)

PDO Parameter TxPDO 49

UINT8

RO

0x06 (6dec)

1830:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 49.

OCTET-STRING[6]

RO

31 1A 32 1A 33 1A

Index 1831 AI Input Voltage TxPDO-Par Compact (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1831:0

AI Input Voltage TxPDO-Par Compact (INT16)

PDO Parameter TxPDO 50

UINT8

RO

0x06 (6dec)

1831:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 50.

OCTET-STRING[6]

RO

30 1A 32 1A 33 1A

Index 1832 AI Input Voltage TxPDO-Par Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1832:0

AI Input Voltage TxPDO-Par Standard (Real32)

PDO Parameter TxPDO 51

UINT8

RO

0x06 (6dec)

1832:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 51.

OCTET-STRING[6]

RO

30 1A 31 1A 33 1A

Index 1833 AI Input Voltage TxPDO-Par Compact (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1833:0

AI Input Voltage TxPDO-Par Compact (Real32)

PDO Parameter TxPDO 52

UINT8

RO

0x06 (6dec)

1833:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 52.

OCTET-STRING[6]

RO

30 1A 31 1A 32 1A

Index 1850 AI Output Voltage TxPDO-Par Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1850:0

AI Output Voltage TxPDO-Par Standard (INT16)

PDO Parameter TxPDO 81

UINT8

RO

0x06 (6dec)

1850:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 81.

OCTET-STRING[6]

RO

51 1A 52 1A 53 1A

Index 1851 AI Output Voltage TxPDO-Par Compact (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1851:0

AI Output Voltage TxPDO-Par Compact (INT16)

PDO Parameter TxPDO 82

UINT8

RO

0x06 (6dec)

1851:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 82.

OCTET-STRING[6]

RO

50 1A 52 1A 53 1A

Index 1852 AI Output Voltage TxPDO-Par Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1852:0

AI Output Voltage TxPDO-Par Standard (Real32)

PDO Parameter TxPDO 83

UINT8

RO

0x06 (6dec)

1852:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 83.

OCTET-STRING[6]

RO

50 1A 51 1A 53 1A

Index 1853 AI Output Voltage TxPDO-Par Compact (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1853:0

AI Output Voltage TxPDO-Par Compact (Real32)

PDO Parameter TxPDO 84

UINT8

RO

0x06 (6dec)

1853:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 84.

OCTET-STRING[6]

RO

50 1A 51 1A 52 1A

Index 1860 AI Output Current TxPDO-Par Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1860:0

AI Output Current TxPDO-Par Standard (INT16)

PDO Parameter TxPDO 97

UINT8

RO

0x06 (6dec)

1860:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 97.

OCTET-STRING[6]

RO

61 1A 62 1A 63 1A

Index 1861 AI Output Current TxPDO-Par Compact (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1861:0

AI Output Current TxPDO-Par Compact (INT16)

PDO Parameter TxPDO 98

UINT8

RO

0x06 (6dec)

1861:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 98.

OCTET-STRING[6]

RO

60 1A 62 1A 63 1A

Index 1862 AI Output Current TxPDO-Par Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1862:0

AI Output Current TxPDO-Par Standard (Real32)

PDO Parameter TxPDO 99

UINT8

RO

0x06 (6dec)

1862:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 99.

OCTET-STRING[6]

RO

60 1A 61 1A 63 1A

Index 1863 AI Output Current TxPDO-Par Compact (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1863:0

AI Output Current TxPDO-Par Compact (Real32)

PDO Parameter TxPDO 100

UINT8

RO

0x06 (6dec)

1863:06

Exclude TxPDOs

Specifies the TxPDOs (index of TxPDO mapping objects) that must not be transferred together with TxPDO 100.

OCTET-STRING[6]

RO

60 1A 61 1A 62 1A

Index 1A00 AO Output TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A00:0

AO Output TxPDO-Map Status

PDO Mapping TxPDO 1

UINT8

RO

0x08 (8dec)

1A00:01

SubIndex 001

1. PDO Mapping entry (1 bits align)

UINT32

RO

0x0000:00, 1

1A00:02

SubIndex 002

2. PDO Mapping entry (object 0x6000 (AO Output Inputs), entry 0x02 (Output Overload))

UINT32

RO

0x6000:02, 1

1A00:03

SubIndex 003

3. PDO Mapping entry (object 0x6000 (AO Output Inputs), entry 0x03 (Underrange))

UINT32

RO

0x6000:03, 1

1A00:04

SubIndex 004

4. PDO Mapping entry (object 0x6000 (AO Output Inputs), entry 0x04 (Overrange))

UINT32

RO

0x6000:04, 1

1A00:05

SubIndex 005

5. PDO Mapping entry (1 bits align)

UINT32

RO

0x0000:00, 1

1A00:06

SubIndex 006

6. PDO Mapping entry (object 0x6000 (AO Output Inputs), entry 0x06 (Warning))

UINT32

RO

0x6000:06, 1

1A00:07

SubIndex 007

7. PDO Mapping entry (object 0x6000 (AO Output Inputs), entry 0x07 (Error))

UINT32

RO

0x6000:07, 1

1A00:08

SubIndex 008

8. PDO Mapping entry (9 bits align)

UINT32

RO

0x0000:00, 9

Index 1A10 AO Complementary Limit High TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A10:0

AO Complementary Limit High TxPDO-Map Status

PDO Mapping TxPDO 17

UINT8

RO

0x07 (7dec)

1A10:01

SubIndex 001

1. PDO Mapping entry (2 bits align)

UINT32

RO

0x0000:00, 2

1A10:02

SubIndex 002

2. PDO Mapping entry (object 0x6010 (AO Complementary Limit High Inputs), entry 0x03 (Underrange))

UINT32

RO

0x6010:03, 1

1A10:03

SubIndex 003

3. PDO Mapping entry (object 0x6010 (AO Complementary Limit High Inputs), entry 0x04 (Overrange))

UINT32

RO

0x6010:04, 1

1A10:04

SubIndex 004

4. PDO Mapping entry (1 bits align)

UINT32

RO

0x0000:00, 1

1A10:05

SubIndex 005

5. PDO Mapping entry (object 0x6010 (AO Complementary Limit High Inputs), entry 0x06 (Warning))

UINT32

RO

0x6010:06, 1

1A10:06

SubIndex 006

6. PDO Mapping entry (object 0x6010 (AO Complementary Limit High Inputs), entry 0x07 (Error))

UINT32

RO

0x6010:07, 1

1A10:07

SubIndex 007

7. PDO Mapping entry (9 bits align)

UINT32

RO

0x0000:00, 9

Index 1A30 AI Input Voltage TxPDO-Map Standard (INT16)*)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A30:0

AI Input Voltage TxPDO-Map Standard (INT16)

PDO Mapping TxPDO 49

UINT8

RO

0x0B (11dec)

1A30:01

SubIndex 001

1. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x01 (Underrange))

UINT32

RO

0x6030:01, 1

1A30:02

SubIndex 002

2. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x02 (Overrange))

UINT32

RO

0x6030:02, 1

1A30:03

SubIndex 003

3. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x03 (Limit 1))

UINT32

RO

0x6030:03, 2

1A30:04

SubIndex 004

4. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x05 (Limit 2))

UINT32

RO

0x6030:05, 2

1A30:05

SubIndex 005

5. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x07 (Error))

UINT32

RO

0x6030:07, 1

1A30:06

SubIndex 006

6. PDO Mapping entry (4 bits align)

UINT32

RO

0x0000:00, 4

1A30:07

SubIndex 007

7. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x0C (Tare Active))

UINT32

RO

0x6030:0C, 1

1A30:08

SubIndex 008

8. PDO Mapping entry (2 bits align)

UINT32

RO

0x0000:00, 2

1A30:09

SubIndex 009

9. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6030:0F, 1

1A30:0A

SubIndex 010

10. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6030:10, 1

1A30:0B

SubIndex 011

11. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x11 (Value))

UINT32

RO

0x6030:11, 16

*) only for EL9501

Index 1A31 AI Input Voltage TxPDO-Map Compact (INT16)*)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A31:0

AI Input Voltage TxPDO-Map Compact (INT16)

PDO Mapping TxPDO 50

UINT8

RO

0x01 (1dec)

1A31:01

SubIndex 001

1. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x11 (Value))

UINT32

RO

0x6030:11, 16

*) only for EL9501

Index 1A32 AI Input Voltage TxPDO-Map Standard (Real32) *)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A32:0

AI Input Voltage TxPDO-Map Standard (Real32)

PDO Mapping TxPDO 51

UINT8

RO

0x0B (11dec)

1A32:01

SubIndex 001

1. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x01 (Underrange))

UINT32

RO

0x6030:01, 1

1A32:02

SubIndex 002

2. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x02 (Overrange))

UINT32

RO

0x6030:02, 1

1A32:03

SubIndex 003

3. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x03 (Limit 1))

UINT32

RO

0x6030:03, 2

1A32:04

SubIndex 004

4. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x05 (Limit 2))

UINT32

RO

0x6030:05, 2

1A32:05

SubIndex 005

5. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x07 (Error))

UINT32

RO

0x6030:07, 1

1A32:06

SubIndex 006

6. PDO Mapping entry (4 bits align)

UINT32

RO

0x0000:00, 4

1A32:07

SubIndex 007

7. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x0C (Tare Active))

UINT32

RO

0x6030:0C, 1

1A32:08

SubIndex 008

8. PDO Mapping entry (2 bits align)

UINT32

RO

0x0000:00, 2

1A32:09

SubIndex 009

9. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6030:0F, 1

1A32:0A

SubIndex 010

10. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6030:10, 1

1A32:0B

SubIndex 011

11. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6030:13, 32

*) only for EL9501

Index 1A33 AI Input Voltage TxPDO-Map Compact (Real32) *)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A33:0

AI Input Voltage TxPDO-Map Compact (Real32)

PDO Mapping TxPDO 52

UINT8

RO

0x01 (1dec)

1A33:01

SubIndex 001

1. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6030:13, 32

*) only for EL9501

Index 1A34 AI Input Voltage TxPDO-Map Cycle Counter *)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A34:0

AI Input Voltage TxPDO-Map Cycle Counter

PDO Mapping TxPDO 53

UINT8

RO

0x01 (1dec)

1A34:01

SubIndex 001

1. PDO Mapping entry (object 0x6030 (AI Input Voltage Inputs), entry 0x14 (Input Cycle Counter))

UINT32

RO

0x6030:14, 16

*) only for EL9501

Index 1A50 AI Output Voltage TxPDO-Map Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A50:0

AI Output Voltage TxPDO-Map Standard (INT16)

PDO Mapping TxPDO 81

UINT8

RO

0x0B (11dec)

1A50:01

SubIndex 001

1. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x01 (Underrange))

UINT32

RO

0x6050:01, 1

1A50:02

SubIndex 002

2. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x02 (Overrange))

UINT32

RO

0x6050:02, 1

1A50:03

SubIndex 003

3. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x03 (Limit 1))

UINT32

RO

0x6050:03, 2

1A50:04

SubIndex 004

4. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x05 (Limit 2))

UINT32

RO

0x6050:05, 2

1A50:05

SubIndex 005

5. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs entry 0x07 (Error))

UINT32

RO

0x6050:07, 1

1A50:06

SubIndex 006

6. PDO Mapping entry (4 bits align)

UINT32

RO

0x0000:00, 4

1A50:07

SubIndex 007

7. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x0C (Tare Active))

UINT32

RO

0x6050:0C, 1

1A50:08

SubIndex 008

8. PDO Mapping entry (2 bits align)

UINT32

RO

0x0000:00, 2

1A50:09

SubIndex 009

9. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6050:0F, 1

1A50:0A

SubIndex 010

10. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6050:10, 1

1A50:0B

SubIndex 011

11. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x11 (Value))

UINT32

RO

0x6050:11, 16

Index 1A51 AI Output Voltage TxPDO-Map Compact (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A51:0

AI Output Voltage TxPDO-Map Compact (INT16)

PDO Mapping TxPDO 82

UINT8

RO

0x01 (1dec)

1A51:01

SubIndex 001

1. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x11 (Value))

UINT32

RO

0x6050:11, 16

Index 1A52 AI Output Voltage TxPDO-Map Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A52:0

AI Output Voltage TxPDO-Map Standard (Real32)

PDO Mapping TxPDO 83

UINT8

RO

0x0B (11dec)

1A52:01

SubIndex 001

1. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x01 (Underrange))

UINT32

RO

0x6050:01, 1

1A52:02

SubIndex 002

2. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x02 (Overrange))

UINT32

RO

0x6050:02, 1

1A52:03

SubIndex 003

3. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x03 (Limit 1))

UINT32

RO

0x6050:03, 2

1A52:04

SubIndex 004

4. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x05 (Limit 2))

UINT32

RO

0x6050:05, 2

1A52:05

SubIndex 005

5. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x07 (Error))

UINT32

RO

0x6050:07, 1

1A52:06

SubIndex 006

6. PDO Mapping entry (4 bits align)

UINT32

RO

0x0000:00, 4

1A52:07

SubIndex 007

7. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x0C (Tare Active))

UINT32

RO

0x6050:0C, 1

1A52:08

SubIndex 008

8. PDO Mapping entry (2 bits align)

UINT32

RO

0x0000:00, 2

1A52:09

SubIndex 009

9. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6050:0F, 1

1A52:0A

SubIndex 010

10. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6050:10, 1

1A52:0B

SubIndex 011

11. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6050:13, 32

Index 1A53 AI Output Voltage TxPDO-Map Compact (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A53:0

AI Output Voltage TxPDO-Map Compact (Real32)

PDO Mapping TxPDO 84

UINT8

RO

0x01 (1dec)

1A53:01

SubIndex 001

1. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6050:13, 32

Index 1A54 AI Output Voltage TxPDO-Map Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1A54:0

AI Output Voltage TxPDO-Map Cycle Counter

PDO Mapping TxPDO 85

UINT8

RO

0x01 (1dec)

1A54:01

SubIndex 001

1. PDO Mapping entry (object 0x6050 (AI Output Voltage Inputs), entry 0x14 (Input Cycle Counter))

UINT32

RO

0x6050:14, 16

Index 1A60 AI Output Current TxPDO-Map Standard (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A60:0

AI Output Current TxPDO-Map Standard (INT16)

PDO Mapping TxPDO 97

UINT8

RO

0x0B (11dec)

1A60:01

SubIndex 001

1. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x01 (Underrange))

UINT32

RO

0x6060:01, 1

1A60:02

SubIndex 002

2. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x02 (Overrange))

UINT32

RO

0x6060:02, 1

1A60:03

SubIndex 003

3. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x03 (Limit 1))

UINT32

RO

0x6060:03, 2

1A60:04

SubIndex 004

4. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x05 (Limit 2))

UINT32

RO

0x6060:05, 2

1A60:05

SubIndex 005

5. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x07 (Error))

UINT32

RO

0x6060:07, 1

1A60:06

SubIndex 006

6. PDO Mapping entry (4 bits align)

UINT32

RO

0x0000:00, 4

1A60:07

SubIndex 007

7. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x0C (Tare Active))

UINT32

RO

0x6060:0C, 1

1A60:08

SubIndex 008

8. PDO Mapping entry (2 bits align)

UINT32

RO

0x0000:00, 2

1A60:09

SubIndex 009

9. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6060:0F, 1

1A60:0A

SubIndex 010

10. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6060:10, 1

1A60:0B

SubIndex 011

11. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x11 (Value))

UINT32

RO

0x6060:11, 16

Index 1A61 AI Output Current TxPDO-Map Compact (INT16)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A61:0

AI Output Current TxPDO-Map Compact (INT16)

PDO Mapping TxPDO 98

UINT8

RO

0x01 (1dec)

1A61:01

SubIndex 001

1. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x11 (Value))

UINT32

RO

0x6060:11, 16

Index 1A62 AI Output Current TxPDO-Map Standard (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A62:0

AI Output Current TxPDO-Map Standard (Real32)

PDO Mapping TxPDO 99

UINT8

RO

0x0B (11dec)

1A62:01

SubIndex 001

1. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x01 (Underrange))

UINT32

RO

0x6060:01, 1

1A62:02

SubIndex 002

2. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x02 (Overrange))

UINT32

RO

0x6060:02, 1

1A62:03

SubIndex 003

3. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x03 (Limit 1))

UINT32

RO

0x6060:03, 2

1A62:04

SubIndex 004

4. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x05 (Limit 2))

UINT32

RO

0x6060:05, 2

1A62:05

SubIndex 005

5. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x07 (Error))

UINT32

RO

0x6060:07, 1

1A62:06

SubIndex 006

6. PDO Mapping entry (4 bits align)

UINT32

RO

0x0000:00, 4

1A62:07

SubIndex 007

7. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x0C (Tare Active))

UINT32

RO

0x6060:0C, 1

1A62:08

SubIndex 008

8. PDO Mapping entry (2 bits align)

UINT32

RO

0x0000:00, 2

1A62:09

SubIndex 009

9. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x0F (TxPDO State))

UINT32

RO

0x6060:0F, 1

1A62:0A

SubIndex 010

10. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x10 (TxPDO Toggle))

UINT32

RO

0x6060:10, 1

1A62:0B

SubIndex 011

11. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6060:13, 32

Index 1A63 AI Output Current TxPDO-Map Compact (Real32)

Index (hex)

Name

Meaning

Data type

Flags

Default

1A63:0

AI Output Current TxPDO-Map Compact (Real32)

PDO Mapping TxPDO 100

UINT8

RO

0x01 (1dec)

1A63:01

SubIndex 001

1. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x13 (Value (Real32)))

UINT32

RO

0x6060:13, 32

Index 1A64 AI Output Current TxPDO-Map Cycle Counter

Index (hex)

Name

Meaning

Data type

Flags

Default

1A64:0

AI Output Current TxPDO-Map Cycle Counter

PDO Mapping TxPDO 101

UINT8

RO

0x01 (1dec)

1A64:01

SubIndex 001

1. PDO Mapping entry (object 0x6060 (AI Output Current Inputs), entry 0x14 (Input Cycle Counter))

UINT32

RO

0x6060:14, 16

Index 1C00 Sync manager type

Index (hex)

Name

Meaning

Data type

Flags

Default

1C00:0

Sync manager type

Using the sync managers

UINT8

RO

0x04 (4dec)

1C00:01

SubIndex 001

Sync-Manager Type Channel 1: Mailbox Write

UINT8

RO

0x01 (1dec)

1C00:02

SubIndex 002

Sync-Manager Type Channel 2: Mailbox Read

UINT8

RO

0x02 (2dec)

1C00:03

SubIndex 003

Sync-Manager Type Channel 3: Process Data Write (Outputs)

UINT8

RO

0x03 (3dec)

1C00:04

SubIndex 004

Sync-Manager Type Channel 4: Process Data Read (Inputs)

UINT8

RO

0x04 (4dec)

Index 1C12 RxPDO assign

Index (hex)

Name

Meaning

Data type

Flags

Default

1C12:0

RxPDO assign

PDO Assign Outputs

UINT8

RW

0x01 (1dec)

1C12:01

Subindex 001

1. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x1603 (5635dec)

1C12:02

Subindex 002

2. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C12:03

Subindex 003

3. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C12:04

Subindex 004

4. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C12:05

Subindex 005

5. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C12:06

Subindex 006

6. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C12:07

Subindex 007

7. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C12:08

Subindex 008

8. allocated RxPDO (contains the index of the associated RxPDO mapping object)

UINT16

RW

0x0000 (0dec)

Index 1C13 TxPDO assign

Index (hex)

Name

Meaning

Data type

Flags

Default

1C13:0

TxPDO assign

PDO Assign Inputs

UINT8

RW

0x03 (3dec)

1C13:01

Subindex 001

1. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A00 (6656dec)

1C13:02

Subindex 002

2. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A52 (6738dec)

1C13:03

Subindex 003

3. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x1A62 (6754dec)

1C13:04

Subindex 004

4. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:05

Subindex 005

5. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:06

Subindex 006

6. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:07

Subindex 007

7. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:08

Subindex 008

8. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:09

Subindex 009

9. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:0A

Subindex 010

10. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:0B

Subindex 011

11. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:0C

Subindex 012

12. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

1C13:0D

Subindex 013

13. allocated TxPDO (contains the index of the associated TxPDO mapping object)

UINT16

RW

0x0000 (0dec)

Index 1C32 SM output parameter

Index (hex)

Name

Meaning

Data type

Flags

Default

1C32:0

SM output parameter

Synchronization parameters for the outputs

UINT8

RO

0x20 (32dec)

1C32:01

Sync mode

Current sync mode:

  • 0: Free Run
  • 1: Synchron with SM 2 Event
  • 2: DC-Mode - Synchron with SYNC0 Event
  • 3: DC-Mode - Synchron with SYNC1 Event

UINT16

RW

0x0000 (0dec)

1C32:02

Cycle time

Cycle time (in ns):

  • Free Run: cycle time of the local timer
  • Synchron with SM 2 Event: cycle time of the master
  • DC-Mode: SYNC0/SYNC1 Cycle Time

UINT32

RW

0x000F4240 (1000000dec)

1C32:03

Shift time

Time between SYNC0 event and output of the outputs (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C32:04

Sync modes supported

Sync modes supported:

  • Bit 0 = 1: Free Run is supported
  • Bit 1 = 1: Synchron with SM 2 Event is supported
  • Bit 2-3 = 01: DC mode is supported
  • Bit 4-5 = 10: Output Shift with SYNC1 Event (DC mode only)
  • Bit 14 = 1: dynamic times (measurement through writing of 0x1C32:08)

UINT16

RO

0x0001 (1dec)

1C32:05

Minimum cycle time

Minimum cycle time (in ns)

UINT32

RO

0x000F4240 (1000000dec)

1C32:06

Calc and copy time

Minimum time between SYNC0 and SYNC1 event (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C32:07

Minimum delay time

 

UINT32

RO

0x00000000 (0dec)

1C32:08

Get Cycle Time

  • 0: Measurement of the local cycle time is stopped
  • 1: Measurement of the local cycle time is started

The entries 0x1C32:03, 0x1C32:05, 0x1C32:06, 0x1C32:09, 0x1C33:03, 0x1C33:06, 0x1C33:09 are updated with the maximum measured values.
For a subsequent measurement the measured values are reset.

UINT16

RW

0x0000 (0dec)

1C32:09

Maximum delay time

Time between SYNC1 event and output of the outputs (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C32:0B

SM event missed counter

Number of missed SM events in OPERATIONAL (DC mode only)

UINT16

RO

0x0000 (0dec)

1C32:0C

Cycle exceeded counter

Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early)

UINT16

RO

0x0000 (0dec)

1C32:0D

Shift too short counter

Number of intervals between SYNC0 and SYNC1 events that are too short (DC mode only)

UINT16

RO

0x0000 (0dec)

1C32:20

Sync error

The synchronization was not correct in the last cycle (outputs were output too late, DC mode only)

BOOLEAN

RO

0x00 (0dec)

Index 1C33 SM input parameter

Index (hex)

Name

Meaning

Data type

Flags

Default

1C33:0

SM input parameter

Synchronization parameters for the inputs

UINT8

RO

0x20 (32dec)

1C33:01

Sync mode

Current sync mode:

  • 0: Free Run
  • 1: Synchron with SM 3 Event (no outputs available)
  • 2: DC - Synchron with SYNC0 Event
  • 3: DC - Synchron with SYNC1 Event
  • 34: Synchron with SM 2 Event (outputs available)

UINT16

RW

0x0000 (0dec)

1C33:02

Cycle time

UINT32

RW

0x000F4240 (1000000dec)

1C33:03

Shift time

Time between SYNC0 event and reading of the inputs (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C33:04

Sync modes supported

Sync modes supported:

  • Bit 0: Free Run is supported
  • Bit 1: Synchron with SM 2 Event is supported (outputs available)
  • Bit 1: Synchron with SM 3 Event is supported (no outputs available)
  • Bit 2-3 = 01: DC mode is supported
  • Bit 4-5 = 01: Input shift through local event (outputs available)
  • Bit 4-5 = 10: Input shift with SYNC1 event (no outputs available)
  • Bit 14 = 1: dynamic times (measurement through writing of 0x1C32:08 or 0x1C33:08)

UINT16

RO

0x0001 (1dec)

1C33:05

Minimum cycle time

as 0x1C32:05

UINT32

RO

0x000F4240 (1000000dec)

1C33:06

Calc and copy time

Time between reading of the inputs and the inputs being available for the master (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C33:07

Minimum delay time

 

UINT32

RO

0x00000000 (0dec)

1C33:08

Get Cycle Time

as 0x1C32:08

UINT16

RW

0x0000 (0dec)

1C33:09

Maximum delay time

Time between SYNC1 event and reading of the inputs (in ns, DC mode only)

UINT32

RO

0x00000000 (0dec)

1C33:0B

SM event missed counter

as 0x1C32:11

UINT16

RO

0x0000 (0dec)

1C33:0C

Cycle exceeded counter

as 0x1C32:12

UINT16

RO

0x0000 (0dec)

1C33:0D

Shift too short counter

as 0x1C32:13

UINT16

RO

0x0000 (0dec)

1C33:20

Sync error

as 0x1C32:32

BOOLEAN

RO

0x00 (0dec)

Index F008 code word

Index (hex)

Name

Meaning

Data type

Flags

Default

F008:0

Code word

Code word (currently reserved)

UINT32

RW

0x00000000 (0dec)

Index F009 Password protection

Index (hex)

Name

Meaning

Data type

Flags

Default

F009:0

Password protection

Password protection user calibration

UINT32

RW

0x00000000 (0dec)