Information and diagnosis data (channel specific)
Index 9000 DCM Info data Ch.1
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
---|---|---|---|---|---|
9000:0 |
DCM Info data Ch.1 |
Max. Subindex |
UINT8 |
RO |
0x09 (9dec) |
9000:01 |
Status word |
Status word (see Index App0) |
UINT16 |
RO |
0x0000 (0dec) |
9000:02 |
Motor coil voltage |
Present coil voltage |
UINT16 |
RO |
0x0000 (0dec) |
9000:03 |
Motor coil current |
Present coil current |
INT16 |
RO |
0x0000 (0dec) |
9000:04 |
Current limit |
Present current limit |
UINT16 |
RO |
0x0000 (0dec) |
9000:05 |
Control error |
Present control error |
INT16 |
RO |
0x0000 (0dec) |
9000:06 |
Duty cycle |
Present Duty-Cycle |
INT8 |
RO |
0x00 (0dec) |
9000:09 |
Overload time |
Time since overload |
UINT16 |
RO |
0x0000 (0dec) |
Index 9010 DCM Info data Ch.2
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
---|---|---|---|---|---|
9010:0 |
DCM Info data Ch.2 |
Max. Subindex |
UINT8 |
RO |
0x09 (9dec) |
9010:01 |
Status word |
Status word (see Index App0) |
UINT16 |
RO |
0x0000 (0dec) |
9010:02 |
Motor coil voltage |
Present coil voltage |
UINT16 |
RO |
0x0000 (0dec) |
9010:03 |
Motor coil current |
Present coil current |
INT16 |
RO |
0x0000 (0dec) |
9010:04 |
Current limit |
Present current limit |
UINT16 |
RO |
0x0000 (0dec) |
9010:05 |
Control error |
Present control error |
INT16 |
RO |
0x0000 (0dec) |
9010:06 |
Duty cycle |
Present Duty-Cycle |
INT8 |
RO |
0x00 (0dec) |
9010:09 |
Overload time |
Time since overload |
UINT16 |
RO |
0x0000 (0dec) |
Index A000 DCM Diag data Ch.1
Index (hex) | Name | Meaning | Data type | Flags | Default | |
---|---|---|---|---|---|---|
A000:0 | DCM Diag data Ch.1 | Max. Subindex | UINT8 | RO | 0x11 (17dec) | |
A000:01 | Saturated | Driver stage operates with maximum duty cycle | Warning | BOOLEAN | RO | 0x00 (0dec) |
A000:02 | Over temperature | Internal terminal temperature is greater than 80 °C | Warning | BOOLEAN | RO | 0x00 (0dec) |
A000:03 | Torque overload | Present motor current exceeds the nominal current (see 0x8020:02) | Warning (0x8pp2:0A = 0) / Error (0x8pp2:0A = 1) | BOOLEAN | RO | 0x00 (0dec) |
A000:04 | Under voltage | Supply voltage less than 7 V | Error | BOOLEAN | RO | 0x00 (0dec) |
A000:05 | Over voltage | Supply voltage 10 % higher than the nominal voltage (see 0x8020:03) | Error | BOOLEAN | RO | 0x00 (0dec) |
A000:06 | Short circuit | Short circuit in the driver stage | Error | BOOLEAN | RO | 0x00 (0dec) |
A000:08 | No control power | No power supply to driver stage | Error | BOOLEAN | RO | 0x00 (0dec) |
A000:09 | Misc error |
| Error | BOOLEAN | RO | 0x00 (0dec) |
A000:11 | Actual operation mode | Present operating mode (in the case of automatic detection of operating mode, see 0x8022:01) | BIT4 | RO | 0x00 (0dec) |
Index A010 DCM Diag data Ch.2
Index (hex) | Name | Meaning | Data type | Flags | Default | |
---|---|---|---|---|---|---|
A010:0 | DCM Diag data Ch.2 | Max. Subindex | UINT8 | RO | 0x11 (17dec) | |
A010:01 | Saturated | Driver stage operates with maximum duty cycle | Warning | BOOLEAN | RO | 0x00 (0dec) |
A010:02 | Over temperature | Internal terminal temperature is greater than 80 °C | Warning | BOOLEAN | RO | 0x00 (0dec) |
A010:03 | Torque overload | Present motor current exceeds the nominal current (see 8030:02) | Warning (0x8032:0A = 0) / Error (0x8032:0A = 1) | BOOLEAN | RO | 0x00 (0dec) |
A010:04 | Under voltage | Supply voltage less than 7 V | Error | BOOLEAN | RO | 0x00 (0dec) |
A010:05 | Over voltage | Supply voltage 10 % higher than the nominal voltage (see 0x8030:03) | Error | BOOLEAN | RO | 0x00 (0dec) |
A010:06 | Short circuit | Short circuit in the driver stage | Error | BOOLEAN | RO | 0x00 (0dec) |
A010:08 | No control power | No power supply to driver stage | Error | BOOLEAN | RO | 0x00 (0dec) |
A010:09 | Misc error | initialization failed or internal temperature of the terminal exceeds 100 °C (see 0xF80F:05) or motor current exceeds the nominal current (see 0x8032:0A) | Error | BOOLEAN | RO | 0x00 (0dec) |
A010:11 | Actual operation mode | Present operating mode (in the case of automatic detection of operating mode, see 0x8032:01) | BIT4 | RO | 0x00 (0dec) |