Input data
Index 6000 DCM Inputs Ch.1
| 
 Index (hex)  | 
 Name  | 
 Meaning  | 
 Data type  | 
 Flags  | 
 Default  | 
|---|---|---|---|---|---|
| 
 6000:0  | 
 DCM Inputs Ch.1  | 
 Max. Subindex  | 
 UINT8  | 
 RO  | 
 0x12 (18dec)  | 
| 
 6000:01  | 
 Ready to enable  | 
 Driver stage is ready for enabling  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:02  | 
 Ready  | 
 Driver stage is ready for operation  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:03  | 
 Warning  | 
 A warning has occurred (see index 0xA000)  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:04  | 
 Error  | 
 An error has occurred (see index 0xA000)  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:05  | 
 Moving positive  | 
 Driver stage is activated in positive direction  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:06  | 
 Moving negative  | 
 Driver stage is activated in negative direction  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:07  | 
 Torque reduced  | 
 Reduced torque is active  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:0C  | 
 Digital input 1  | 
 Digital input 1  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:0D  | 
 Digital input 2  | 
 Digital input 2  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:0E  | 
 Sync error  | 
 The Sync error bit is only required for DC mode. It indicates whether a synchronization error has occurred during the previous cycle.  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:10  | 
 TxPDO Toggle  | 
 The TxPDO toggle is toggled by the slave when the data of the associated TxPDO is updated.  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6000:11  | 
 Info data 1  | 
 Synchronous information (selection via subindex 0x8022:11)  | 
 UINT16  | 
 RO  | 
 0x0000 (0dec)  | 
| 
 6000:12  | 
 Info data 2  | 
 Synchronous information (selection via subindex 0x8022:19)  | 
 UINT16  | 
 RO  | 
 0x0000 (0dec)  | 
Index 6010 DCM Inputs Ch.2
| 
 Index (hex)  | 
 Name  | 
 Meaning  | 
 Data type  | 
 Flags  | 
 Default  | 
|---|---|---|---|---|---|
| 
 6010:0  | 
 DCM Inputs Ch.2  | 
 Max. Subindex  | 
 UINT8  | 
 RO  | 
 0x12 (18dec)  | 
| 
 6010:01  | 
 Ready to enable  | 
 Driver stage is ready for enabling  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:02  | 
 Ready  | 
 Driver stage is ready for operation  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:03  | 
 Warning  | 
 A warning has occurred (see index 0xA010)  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:04  | 
 Error  | 
 An error has occurred (see index 0xA010)  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:05  | 
 Moving positive  | 
 Driver stage is activated in positive direction  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:06  | 
 Moving negative  | 
 Driver stage is activated in negative direction  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:07  | 
 Torque reduced  | 
 Reduced torque is active  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:0C  | 
 Digital input 1  | 
 Digital input 1  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:0D  | 
 Digital input 2  | 
 Digital input 2  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:0E  | 
 Sync error  | 
 The Sync error bit is only required for DC mode. It indicates whether a synchronization error has occurred during the previous cycle.  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:10  | 
 TxPDO Toggle  | 
 The TxPDO toggle is toggled by the slave when the data of the associated TxPDO is updated.  | 
 BOOLEAN  | 
 RO  | 
 0x00 (0dec)  | 
| 
 6010:11  | 
 Info data 1  | 
 Synchronous information (selection via subindex 0x8032:11)  | 
 UINT16  | 
 RO  | 
 0x0000 (0dec)  | 
| 
 6010:12  | 
 Info data 2  | 
 Synchronous information (selection via subindex 0x8032:19)  | 
 UINT16  | 
 RO  | 
 0x0000 (0dec)  |