EL7201-901x - LEDs and connection

EL7201-901x - LEDs

EL7201-901x - LEDs and connection 1:
Fig.21: EL7201-901x - LEDs

LED

Color

Meaning

RUN

green

This LED indicates the terminal's operating state:

off

State of the EtherCAT State Machine: INIT = initialization of the terminal

flashing
rapidly

State of the EtherCAT State Machine: BOOTSTRAP = function for terminal firmware updates

flashing

State of the EtherCAT State Machine: PREOP = function for mailbox communication and different standard-settings set

Single flash

State of the EtherCAT State Machine: SAFEOP = verification of the Sync Manager channels and the distributed clocks.
Outputs remain in safe state

on

State of the EtherCAT State Machine: OP = normal operating state; mailbox and process data communication is possible

Drive OK

green

on

Driver stage ready for operation

Limit

orange

on

The LED is linked with bit 11 of the status word (MDP742 / DS402) (internal limit active)
Limit reached (e.g. torque or speed limit)

Read OCT

green

flashing

The electronic type plate is being read

off

The reading of the electronic type plate has been completed

Warning

orange

flashing

Error while reading the type plate

on

The LED is linked with bit 7 of the status word (MDP742 / DS402) (warning)
The “Warning” threshold value is exceeded.
I²T model
Voltage missing at STO input
Temperature (80°C) exceeded
Voltage

Enable

green

on

The LED is linked with the bits 1 and 2 of status word  (MDP742 / DS402) (if "Switched on" or "Operation enabled")
Driver stage enabled

Input 1
Input 2

green

on

Signal is present at digital inputs
(e.g. end position, reference or latch sensors/switches)

Error

red

on

The LED is linked with bit 3 of the status word (MDP742 / DS402) (fault)
The “Error” threshold value is exceeded.
Overcurrent
STO triggered with active axis
Voltage not available
Resolver not connected
Max. temperature (100°C) exceeded

+24 V via power contacts

green

on

24 V voltage supply for the terminal is present.

DC link supply

green

on

Voltage for the DC link supply is present.

Notice

Fuse protection of the supply voltage

The electrical protection of the load voltage must be selected in such a way that the maximum flowing current is limited to 3 times the rated current (max. 1 second)!

Connection

EL7201-901x - LEDs and connection 2:
Fig.1: EL7201-901x Connection

Terminal point

Name

Comment

1

OCT +

Positive input of the absolute feedback

2

Input 1

Digital input 1

3

+24 V

Power contact +24 V

4

U

Motor phase U

5

W

Motor phase W

6

Brake +

Motor brake +

7

48 V

DC link supply + (8 ... 48 V)

8

9

OCT -

Negative input of the absolute feedback

10

Input 2

Digital input 2

11

0 V

Power contact 0 V

12

V

Motor phase V

13

STO input

Input for STO signal (24 V)

14

Brake GND

Motor brake 0 V

15

0 V

DC link 0 V supply

16