Process data

Sync Manager (SM)

Sync Manager (SM) The scope of the offered process data can be changed via the "Process data" tab (see Fig. "Tab Process data SM2, EL70xx (default), Process data tab SM3, EL70xx (default)").

Process data 1:
Process Data tab SM2, EL70xx (default)
Process data 2:
Process Data tab SM3, EL70xx (default)

PDO Assignment

SM2, PDO assignment 0x1C12

Index

Index of excluded PDOs

Size (byte.bit)

Name

PDO content
index - name

0x1600 (default)

0x1601

4.0

ENC Control compact

0x7000:01 - Enable Latch C
0x7000:02 - Enable Latch extern on positive edge
0x7000:03 - Set counter
0x7000:04 - Enable Latch extern on negative edge
0x7000:11 - Set counter value (16-bit)

0x1601

0x1600

6.0

ENC Control

0x7000:01 - Enable Latch C
0x7000:02 - Enable Latch extern on positive edge
0x7000:03 - Set counter
0x7000:04 - Enable Latch extern on negative edge
0x7000:11 - Set counter value (32-bit)

0x1602 (default)

-

2.0

STM Control

0x7010:01 - Enable
0x7010:02 - Reset
0x7010:03 - Reduce torque
0x7010:0C - Digital Output 1

0x1603

0x1604
0x1605
0x1606

4.0

STM Position

0x7010:11 - Position

0x1604 (default)

0x1603
0x1605
0x1606

2.0

STM Velocity

0x7010:21 - Velocity

0x1605

0x1603
0x1604
0x1606

6.0

POS Control compact

0x7020:01 - Execute
0x7020:02 - Emergency stop
0x7020:11 - Target position

0x1606

0x1603
0x1604
0x1605

14.0

POS Control

0x7020:01 - Execute
0x7020:02 - Emergency stop
0x7020:11 - Target position
0x7020:21 - Velocity
0x7020:22 - Start type
0x7020:23 - Acceleration
0x7020:24 - Deceleration

0x1607

0x1603
0x1604
0x1605

14.0

POS Control 2

0x7021:03 – Enable auto start
0x7021:03 – Target position
0x7021:21 – Velocity
0x7021:22 – Start type
0x7021:23 – Acceleration
0x7021:24 – Deceleration

SM3, PDO Assignment 0x1C13

Index

Index of excluded PDOs

Size (byte.bit)

Name

PDO content
index - name

0x1A00 (default)

0x1A01

6.0

ENC Status compact

0x6000:01 - Latch C valid
0x6000:02 - Latch extern valid
0x6000:03 - Set counter done
0x6000:04 - Counter underflow
0x6000:05 - Counter overflow
0x6000:08 - Extrapolation stall
0x6000:09 - Status of input A
0x6000:0A - Status of input B
0x6000:0B - Status of input C
0x6000:0D - Status of extern latch
0x6000:0E - Sync error
0x6000:10 - TxPDO Toggle
0x6000:11 - Counter value (16-Bit)
0x6000:12 - Latch value (16-Bit)

0x1A01

0x1A00

10.0

ENC Status

0x6000:01 - Latch C valid
0x6000:02 - Latch extern valid
0x6000:03 - Set counter done
0x6000:04 - Counter underflow
0x6000:05 - Counter overflow
0x6000:08 - Extrapolation stall
0x6000:09 - Status of input A
0x6000:0A - Status of input B
0x6000:0B - Status of input C
0x6000:0D - Status of extern latch
0x6000:0E - Sync error
0x6000:10 - TxPDO Toggle
0x6000:11 - Counter value (32-Bit)
0x6000:12 - Latch value (32-Bit)

0x1A02

-

4.0

ENC Timest. compact

0x6000:16 - Timestamp

0x1A03 (default)

-

2.0

STM Status

0x6010:01 - Ready to enable
0x6010:02 - Ready
0x6010:03 - Warning
0x6010:04 - Error
0x6010:05 - Moving positive
0x6010:06 - Moving negative
0x6010:07 - Torque reduced
0x6010:08 - Motor stall
0x6010:0C - Digital input 1
0x6010:0D - Digital input 2
0x6000:0E - Sync error
0x6000:10 - TxPDO Toggle

0x1A04

-

4.0

STM Synchron info data

0x6010:11 - Info data 1
0x6010:12 - Info data 2

0x1A05

-

2.0

STM Motor load

0x6010:13 - Motor load

SM3, PDO Assignment 0x1C13

Index

Index of excluded PDOs

Size (byte.bit)

Name

PDO content
index - name

0x1A06

0x1A07

2.0

POS Status compact

0x6020:01 - Busy
0x6020:02 - in-Target
0x6020:03 - Warning
0x6020:04 - Error
0x6020:05 - Calibrated
0x6020:06 - Accelerate
0x6020:07 - Decelerate

0x1A07

0x1A06

12.0

POS Status

0x6020:01 - Busy
0x6020:02 - in-Target
0x6020:03 - Warning
0x6020:04 - Error
0x6020:05 - Calibrated
0x6020:06 - Accelerate
0x6020:07 - Decelerate
0x6020:11 - Actual position
0x6020:21 - Actual velocity
0x6020:22 - Actual drive time

0x1A08

-

4.0

STM Internal position

0x6010:14 - Internal position

0x1A09

-

4.0

STM External position

0x6010:15 – External position

0x1A0A

-

4.0

POS Actual position lag

0x6020:23 – Actual position lag

Predefined PDO Assignment

The "Predefined PDO Assignment" enables a simplified selection of the process data. The desired function is selected on the lower part of the "Process Data" tab. As a result, all necessary PDOs are automatically activated and the unnecessary PDOs are deactivated.

The following PDO assignments are available:

Name

SM2, PDO assignment

SM3, PDO assignment

Velocity control compact

0x1600
0x1602
0x1604

0x1A00
0x1A03

Velocity control compact
with info data

0x1600
0x1602
0x1604

0x1A00
0x1A03
0x1A04

Velocity control

0x1601
0x1602
0x1604

0x1A01
0x1A03

Position control

0x1601
0x1602
0x1603

0x1A01
0x1A03

Positioning interface compact

0x1601
0x1602
0x1605

0x1A01
0x1A03
0x1A06

Positioning interface

0x1601
0x1602
0x1606

0x1A01
0x1A03
0x1A07

Positioning interface
with info data

0x1601
0x1602
0x1606

0x1A01
0x1A03
0x1A04
0x1A07

Positioning interface
(Auto start)

0x1601
0x1602
0x1606
0x1607

0x1A01
0x1A03
0x1A06

Positioning interface
(Auto start) with info data

0x1601
0x1602
0x1606
0x1607

0x1A01
0x1A03
0x1A04
0x1A06

Process data 3:
Process data tab - Predefined PDO Assignment, EL70x7