Output data

Index 7000 ENC Outputs Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

7000:0

ENC Outputs Ch.1

Maximum subindex

UINT8

RO

0x11 (17dec)

7000:01

Enable latch C

Activate latching via the C-track.

BOOLEAN

RO

0x00 (0dec)

7000:02

Enable latch extern on positive edge

Activate external latch with positive edge.

BOOLEAN

RO

0x00 (0dec)

7000:03

Set counter

Set the counter value.

BOOLEAN

RO

0x00 (0dec)

7000:04

Enable latch extern on negative edge

Activate external latch with negative edge.

BOOLEAN

RO

0x00 (0dec)

7000:11

Set counter value

This is the counter value to be set via "Set counter".

UINT32

RO

0x00000000 (0dec)

Index 7010 STM Outputs Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

7010:0

STM Outputs Ch.1

Maximum subindex

UINT8

RO

0x21 (33dec)

7010:01

Enable

Activates the output stage

BOOLEAN

RO

0x00 (0dec)

7010:02

Reset

All errors that may have occurred are reset by setting this bit (rising edge)

BOOLEAN

RO

0x00 (0dec)

7010:03

Reduce torque

Activation of reduced torque (coil current) (see subindex 0x8014:06)

BOOLEAN

RO

0x00 (0dec)

7010:11

Position

Set position

UINT32

RO

0x00000000 (0dec)

7010:21

Velocity

Set velocity

INT16

RO

0x0000 (0dec)