Input data
Index 6000 DMX Status (EL6851 Master)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6000:0 | DMX Status | Maximum subindex | UINT8 | RO | 0x12 (18dec) |
6000:01 | Transmit accepted | Data have been transmitted (required only for the RDM protocol) | BOOLEAN | RO | FALSE |
6000:02 | Receive toggle | This bit is toggled if data are received from the slave (required only for the RDM protocol) | BOOLEAN | RO | FALSE |
6000:03 | Cyclic TxD disabled | No data are sent if this value is TRUE | BOOLEAN | RO | FALSE |
6000:04 | Default data sent | Default data are transmitted if this value is TRUE (see index 0x8000:12) | BOOLEAN | RO | FALSE |
6000:0E | Frame sent toggle | This is toggled at each DMX frame | BOOLEAN | RO | FALSE |
6000:10 | TxPDO Toggle | This is toggled after each TxPDO update | BOOLEAN | RO | FALSE |
6000:11 | Channel length | Required only for the RDM protocol. Number of data that were received | UINT16 | RO | 0x0000 (0dec) |
6000:12 | Start code | Start code of the DMX protocol (required only for the RDM protocol) | UINT8 | RO | 0x00 (0dec) |
Index 6000 DMX Status (EL6851-0010 Slave)
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
6000:0 | DMX Status | Maximum subindex | UINT8 | RO | 0x12 (18dec) |
6000:02 | Receive toggle | This bit is toggled if data are received from the slave (required only for the RDM protocol) | BOOLEAN | RO | FALSE |
6000:06 | Framing error | Incorrect start code (not NULL) or the next frame was detected during a transmission | BOOLEAN | RO | FALSE |
6000:07 | Overrun error | Overflow of internal receive buffer | BOOLEAN | RO | FALSE |
6000:0F | TxPDO State | Received data are invalid | BOOLEAN | RO | FALSE |
6000:10 | TxPDO Toggle | This is toggled after each DMX frame | BOOLEAN | RO | FALSE |
6000:11 | Channel length | Number of data that were received | UINT16 | RO | 0x0000 (0dec) |
6000:12 | Start code | Start code of the DMX protocol (required only for the RDM protocol) | UINT8 | RO | 0x00 (0dec) |
Index 600n DMX Input Channel 1 - 64 (65 - 128, 129 - 192, ..., 449 - 512) [for 2 ≤ n ≤ 9]
Index (hex) | Name | Meaning | Data type | Flags | Default |
|---|---|---|---|---|---|
600n:0 | DMX Channel | Maximum subindex | UINT8 | RO | 0x40 (64dec) |
600n:01 | Channel 001 [65;129…;449] | DMX Byte 1 [65;129…; 449] | UINT8 | RO | 0x00 (0dec) |
… | … | … | … | … | … |
600n:40 | Channel 064 [128;192…; 512] | DMX Byte 64 [128;192…; 512] | UINT8 | RO | 0x00 (0dec) |