Technical data
Technical data | EL6761 |
---|---|
Technology | Powerline Communication |
Fieldbus | ISO 15118 |
Number of fieldbus channels | 1 |
Maximum cable length between terminal and EV | 30 m (specified by ISO 15118) |
Interfaces | CP, PP, (ground) |
Communication | PWM communication in accordance with IEC 61851 and high-level communication in accordance with ISO 15118 and DIN 70121 |
Hardware diagnostics | Status LEDs |
Electrical isolation | 1500 V |
Current consumption of power contacts | – |
Current consumption via E-bus | 420 mA typ. |
Configuration | via TwinCAT System Manager |
Weight | approx. 90 g |
Permissible ambient temperature range during operation | -25 °C… +60 °C (extended temperature range)**) |
Permissible ambient temperature range during storage | -40 °C… + 85 °C |
Permissible relative air humidity | 95 %, no condensation |
Dimensions (W x H x D) | approx. 24 mm x 100 mm x 52 mm |
on 35 mm mounting rail, conforms to EN 50022 | |
Vibration / shock resistance | conforms to EN 60068-2-6 / EN 60068-2-27 |
EMC immunity / emission | conforms to EN 61000-6-2 / EN 61000-6-4 |
Protection rating | IP20 |
Installation position | variable |
Approvals / markings* | CE |
*) Real applicable approvals/markings see type plate on the side (product marking).
**) in standard installation position, see chapter "Installation positions" and "Specific safety instructions"