SM2 - Outputs (0x1600 .. 0x1607)
Channel 1 (0x1600 .. 0x1603):
0x1600 - ENC Control Channel 1 (6.0) | |
|---|---|
Contents | Excluded PDOs |
0x7000:02 - Control_Enable latch extern on positive edge (0.1) 0x7000:11 - Set counter value (4.0) | 0x1601 - ENC Control Compact Channel 1 (4.0) 0x1602 - ENC Control Counter Channel 1 (6.0) 0x1603 - ENC Control Compact Counter Channel 1 (4.0) |
0x1601 - ENC Control Compact Channel 1 (4.0) | |
|---|---|
Contents | Excluded PDOs |
0x7000:02 - Control_Enable latch extern on positive edge (0.1) 0x7000:11 - Set counter value (2.0) | 0x1600 - ENC Control Channel 1 (6.0) 0x1602 - ENC Control Counter Channel 1 (6.0) 0x1603 - ENC Control Compact Counter Channel 1 (4.0) |
0x1602 - ENC Control Counter Channel 1 (6.0) | |
|---|---|
Contents | Excluded PDOs |
0x7000:03 - Control_Set counter (0.1) 0x7000:11 - Set counter value (4.0) | 0x1600 - ENC Control Channel 1 (6.0) 0x1601 - ENC Control Compact Channel 1 (4.0) 0x1603 - ENC Control Compact Counter Channel 1 (4.0) |
0x1603 - ENC Control Compact Counter Channel 1 (4.0) | |
|---|---|
Contents | Excluded PDOs |
0x7000:03 - Control_Set counter (0.1) 0x7000:11 - Set counter value (2.0) | 0x1600 - ENC Control Channel 1 (6.0) 0x1601 - ENC Control Compact Channel 1 (4.0) 0x1602 - ENC Control Counter Channel 1 (6.0) |
Channel 2 (0x1604 .. 0x1607):
0x1604 - ENC Control Channel 2 (6.0) | |
|---|---|
Contents | Excluded PDOs |
0x7010:02 - Control_Enable latch extern on positive edge (0.1) 0x7010:11 - Set counter value (4.0) | 0x1605 - ENC Control Compact Channel 2 (4.0) 0x1606 - ENC Control Counter Channel 2 (6.0) 0x1607 - ENC Control Compact Counter Channel 2 (4.0) |
0x1605 - ENC Control Compact Channel 2 (4.0) | |
|---|---|
Contents | Excluded PDOs |
0x7010:02 - Control_Enable latch extern on positive edge (0.1) 0x7010:11 - Set counter value (2.0) | 0x1604 - ENC Control Channel 2 (6.0) 0x1606 - ENC Control Counter Channel 2 (6.0) 0x1607 - ENC Control Compact Counter Channel 2 (4.0) |
0x1606 - ENC Control Counter Channel 2 (6.0) | |
|---|---|
Contents | Excluded PDOs |
0x7010:03 - Control_Set counter (0.1) 0x7010:11 - Set counter value (4.0) | 0x1604 - ENC Control Channel 2 (6.0) 0x1605 - ENC Control Compact Channel 2 (4.0) 0x1607 - ENC Control Compact Counter Channel 2 (4.0) |
0x1607 - ENC Control Compact Counter Channel 2 (4.0) | |
|---|---|
Contents | Excluded PDOs |
0x7010:03 - Control_Set counter (0.1) 0x7010:11 - Set counter value (2.0) | 0x1604 - ENC Control Channel 2 (6.0) 0x1605 - ENC Control Compact Channel 2 (4.0) 0x1606 - ENC Control Counter Channel 2 (6.0) |