Overview of functions
The EL5112 offers a wide range of functions. The following table provides an overview of the functions provided in two-channel mode. A detailed description can be found in the individual chapters.
To use the extended functions, the corresponding functions must be selected via the "Predefined PDO Assignment". The assignment is described in chapter "Process data".
| Basic functions | Description | 
|---|---|
| Encoders or counters/pulse generators with signal levels according to RS422, TTL or OpenCollector can be selected. | |
| The encoder supply is set centrally for both channels either to 5 VDC, 12 VDC or 24 VDC. | |
| The input signal can be subject to 4-fold, 2-fold or 1-fold evaluation. | |
| The value range within which counting takes place can be defined. | |
| If the count limit is exceeded or underrun, this is indicated in separate process data. | |
| The counting direction can be adapted to the application. | |
| Allows a recurring reset of the counter value via an edge (positive/negative) at the gate/latch combination input. | |
| The counter value can be set at runtime to a predefined counter value via a PLC variable or an edge (positive/negative) at the gate/latch combination input. | |
| The current counter value can be stored, independent of the cycle time, in a separate process record via an edge (positive/negative) at the gate/latch combination input. You can parameterize whether the function is executed at each external edge or only once after each activation. | |
| The counter value can be disabled via an edge (positive/negative) at the gate/latch combination input or a PLC variable. | 
| Extended functionalities | Description | 
|---|---|
| The average frequency of the input signal within a given timeframe can be output directly. | |
| The period value of the last period within the PLC cycle can be output directly. | |
| The average velocity or speed of the input signal within a specified timeframe can be output directly. | |
| To suppress interference, a filter can be set for each of the input signals. | |
| Error messages are communicated to the EtherCAT Master / TwinCAT via "DiagMessages". | 
| Process data | Description | 
|---|---|
| The scope of the process data can be selected via "Predefined PDO Assignment". | |
| In addition to the frame-triggered operation mode (SM mode), a mode based on synchronization via the distributed clocks is available. | 
| Description of the inputs | Description | 
|---|---|
| One gate/latch combination input is provided per channel for 24 VDC signals with a minimum pulse duration of tON > 1 µs. This can be used for resetting, setting and storing the counter value. |