Standard objects

Standard objects (0x1000-0x1FFF)

The standard objects have the same meaning for all EtherCAT slaves.

Index 1000 Device type

Index (hex)

Name

Meaning

Data type

Flags

Default

1000:0

Device type

Device type of the EtherCAT slave: the Lo-Word contains the profile used (5001).

UINT32

RO

0x01541389

Index 1008 Device name

Index (hex)

Name

Meaning

Data type

Flags

Default

1008:0

Device name

Device name of the EtherCAT slave

STRING

RO

EL3403

Index 1009 Hardware version

Index (hex)

Name

Meaning

Data type

Flags

Default

1009:0

Hardware version

Hardware version of the EtherCAT slave

STRING

RO

01

Index 100A Software version

Index (hex)

Name

Meaning

Data type

Flags

Default

100A:0

Software version

Firmware version of the EtherCAT slave

STRING

RO

01

Index 1018 Identity

Index (hex)

Name

Meaning

Data type

Flags

Default

1018:0

Identity

Length of this object

UINT8

RO

4

1018:01

Vendor ID

Vendor ID of the EtherCAT slave

UINT32

RO

2

1018:02

Product code

Product code of the EtherCAT slave

UINT32

RO

0x0D4B3052 (223031378dec)

1018:03

Revision

Revision number of the EtherCAT slave; the low word (bit 0-15) indicates the special terminal number, the high word (bit 16-31) refers to the device description

UINT32

RO

0x00100000 (1048576dec)

1018:04

Serial number

Serial number of the EtherCAT slave; the low byte (bit 0-7) of the low word contains the year of production, the high byte (bit 8-15) of the low word contains the week of production, the high word (bit 16-31) is 0

UINT32

RO

e.g. 0x00001E06 (KW 30/2006)

Index 10F0 Backup parameter

Index (hex)

Name

Meaning

Data type

Flags

Default

10F0:0

Backup parameter

Length of this object

UINT8

RO

0x01

10F0:01

Checksum

Checksum

UINT32

RW

0x00000000 (0dec)

Index 1600 RxPDO-Map Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1600:0

RxPDO-Map Ch.1

PDO mapping of RxPDO 1

UINT8

RO

0x01

1600:01

SubIndex 001

1. PDO Mapping entry (object 0x7000 (PM Outputs Ch.1), entry 0x01 (Index))

UINT32

RW

0x7000:01, 8

Index 1601 RxPDO-Map Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

1601:0

RxPDO-Map Ch.2

PDO mapping of RxPDO 2

UINT8

RO

0x01 (1dec)

1601:01

SubIndex 001

1. PDO Mapping entry (object 0x7010 (PM Outputs Ch.2), entry 0x01 (Index))

UINT32

RW

0x7010:01, 8

Index 1602 RxPDO-Map Ch.3

Index (hex)

Name

Meaning

Data type

Flags

Default

1602:0

RxPDO-Map Ch.3

PDO mapping of RxPDO 3

UINT8

RO

0x01 (1dec)

1602:01

SubIndex 001

1. PDO Mapping entry (object 0x7020 (PM Outputs Ch.3), entry 0x01 (Index))

UINT32

RW

0x7020:01, 8

Index 1A00 TxPDO-Map Ch.1

Index (hex)

Name

Meaning

Data type

Flags

Default

1A00:0

TxPDO-Map Ch.1

PDO Mapping of TxPDO 1

UINT8

RO

0x0A (10dec)

1A00:01

SubIndex 001

1. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 13

1A00:02

SubIndex 002

2. PDO Mapping entry (object 0x1C32 (SM output parameter), entry 0x20 (Sync error))

UINT32

RW

0x1C32:20, 1

1A00:03

SubIndex 003

3. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 1

1A00:04

SubIndex 004

4. PDO Mapping entry ()

UINT32

RW

0x1800:09, 1

1A00:05

SubIndex 005

5. PDO Mapping entry (object 0x6000 (PM Inputs Ch.1), entry 0x11 (Current))

UINT32

RW

0x6000:11, 32

1A00:06

SubIndex 006

6. PDO Mapping entry (object 0x6000 (PM Inputs Ch.1), entry 0x12 (Voltage))

UINT32

RW

0x6000:12, 32

1A00:07

SubIndex 007

7. PDO Mapping entry (object 0x6000 (PM Inputs Ch.1), entry 0x13 (Active power))

UINT32

RW

0x6000:13, 32

1A00:08

SubIndex 008

8. PDO Mapping entry (object 0x6000 (PM Inputs Ch.1), entry 0x14 (Index))

UINT32

RW

0x6000:14, 8

1A00:09

SubIndex 009

9. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 8

1A00:0A

SubIndex 010

10. PDO Mapping entry (object 0x6000 (PM Inputs Ch.1), entry 0x1D (VariantValue))

UINT32

RW

0x6000:1D, 32

Index 1A01 TxPDO-Map Ch.2

Index (hex)

Name

Meaning

Data type

Flags

Default

1A01:0

TxPDO-Map Ch.2

PDO Mapping of TxPDO 2

UINT8

RO

0x0A (10dec)

1A01:01

SubIndex 001

1. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 13

1A01:02

SubIndex 002

2. PDO Mapping entry (object 0x1C32 (SM output parameter), entry 0x20 (Sync error))

UINT32

RW

0x1C32:20, 1

1A01:03

SubIndex 003

3. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 1

1A01:04

SubIndex 004

4. PDO Mapping entry ()

UINT32

RW

0x1801:09, 1

1A01:05

SubIndex 005

5. PDO Mapping entry (object 0x6010 (PM Inputs Ch.2), entry 0x11 (Current))

UINT32

RW

0x6010:11, 32

1A01:06

SubIndex 006

6. PDO Mapping entry (object 0x6010 (PM Inputs Ch.2), entry 0x12 (Voltage))

UINT32

RW

0x6010:12, 32

1A01:07

SubIndex 007

7. PDO Mapping entry (object 0x6010 (PM Inputs Ch.2), entry 0x13 (Active power))

UINT32

RW

0x6010:13, 32

1A01:08

SubIndex 008

8. PDO Mapping entry (object 0x6010 (PM Inputs Ch.2), entry 0x14 (Index))

UINT32

RW

0x6010:14, 8

1A01:09

SubIndex 009

9. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 8

1A01:0A

SubIndex 010

10. PDO Mapping entry (object 0x6010 (PM Inputs Ch.2), entry 0x1D (VariantValue))

UINT32

RW

0x6010:1D, 32

Index 1A02 TxPDO-Map Ch.3

Index (hex)

Name

Meaning

Data type

Flags

Default

1A02:0

TxPDO-Map Ch.3

PDO Mapping of TxPDO 3

UINT8

RO

0x0A (10dec)

1A02:01

SubIndex 001

1. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 13

1A02:02

SubIndex 002

2. PDO Mapping entry (object 0x1C32 (SM output parameter), entry 0x20 (Sync error))

UINT32

RW

0x1C32:20, 1

1A02:03

SubIndex 003

3. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 1

1A02:04

SubIndex 004

4. PDO Mapping entry ()

UINT32

RW

0x1802:09, 1

1A02:05

SubIndex 005

5. PDO Mapping entry (object 0x6020 (PM Inputs Ch.3), entry 0x11 (Current))

UINT32

RW

0x6020:11, 32

1A02:06

SubIndex 006

6. PDO Mapping entry (object 0x6020 (PM Inputs Ch.3), entry 0x12 (Voltage))

UINT32

RW

0x6020:12, 32

1A02:07

SubIndex 007

7. PDO Mapping entry (object 0x6020 (PM Inputs Ch.3), entry 0x13 (Active power))

UINT32

RW

0x6020:13, 32

1A02:08

SubIndex 008

8. PDO Mapping entry (object 0x6020 (PM Inputs Ch.3), entry 0x14 (Index))

UINT32

RW

0x6020:14, 8

1A02:09

SubIndex 009

9. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 8

1A02:0A

SubIndex 010

10. PDO Mapping entry (object 0x6020 (PM Inputs Ch.3), entry 0x1D (VariantValue))

UINT32

RW

0x6020:1D, 32

Index 1A03 TxPDO-Map Status

Index (hex)

Name

Meaning

Data type

Flags

Default

1A03:0

TxPDO-Map Status

PDO Mapping of TxPDO 4

UINT8

RO

0x09 (9dec)

1A03:01

SubIndex 001

1. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 3

1A03:02

SubIndex 002

2. PDO Mapping entry ()

UINT32

RW

0xF130:04, 1

1A03:03

SubIndex 003

3. PDO Mapping entry ()

UINT32

RW

0xF130:05, 1

1A03:04

SubIndex 004

4. PDO Mapping entry ()

UINT32

RW

0xF130:06, 1

1A03:05

SubIndex 005

5. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 2

1A03:06

SubIndex 006

6. PDO Mapping entry ()

UINT32

RW

0xF130:09, 1

1A03:07

SubIndex 007

7. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 4

1A03:08

SubIndex 008

8. PDO Mapping entry (object 0x1C32 (SM output parameter), entry 0x20 (Sync error))

UINT32

RW

0x1C32:20, 1

1A03:09

SubIndex 009

9. PDO Mapping entry (Align)

UINT32

RW

0x0000:00, 2

Index 1C00 Sync manager type

Index (hex)

Name

Meaning

Data type

Flags

Default

1C00:0

Sync manager type

Length of this object

UINT8

RO

0x04 (4dec)

1C00:01

SubIndex 001

Sync-Manager Type Channel 1: Mailbox Write

UINT8

RW

0x01 (1dec)

1C00:02

SubIndex 002

Sync-Manager Type Channel 2: Mailbox Read

UINT8

RW

0x02 (2dec)

1C00:03

SubIndex 003

Sync-Manager Type Channel 3: Process Data Write (Outputs)

UINT8

RW

0x03 (3dec)

1C00:04

SubIndex 004

Sync-Manager Type Channel 4: Process Data Read (Inputs)

UINT8

RW

0x04 (4dec)

Index 1C12 RxPDO assign

Index (hex)

Name

Meaning

Data type

Flags

Default

1C12:0

RxPDO assign

PDO Assign of Outputs

UINT8

RO

0x03 (3dec)

1C12:01

Subindex 001

1. assigned PDO (RxPDO-Map Ch.1 (RxPDO 1))

UINT16

RW

0x1600 (5632dec)

1C12:02

Subindex 002

2. assigned PDO (RxPDO-Map Ch.2 (RxPDO 2))

UINT16

RW

0x1601 (5633dec)

1C12:03

Subindex 003

3. assigned PDO (RxPDO-Map Ch.3 (RxPDO 3))

UINT16

RW

0x1602 (5634dec)

Index 1C13 TxPDO assign

Index (hex)

Name

Meaning

Data type

Flags

Default

1C13:0

TxPDO assign

PDO Assign of Inputs

UINT8

RO

0x04 (4dec)

1C13:01

Subindex 001

1. assigned PDO (TxPDO-Map Ch.1 (TxPDO 1))

UINT16

RW

0x1A00 (6656dec)

1C13:02

Subindex 002

2. assigned PDO (TxPDO-Map Ch.2 (TxPDO 2))

UINT16

RW

0x1A01 (6657dec)

1C13:03

Subindex 003

3. assigned PDO (TxPDO-Map Ch.3 (TxPDO 3))

UINT16

RW

0x1A02 (6658dec)

1C13:04

Subindex 004

4. assigned PDO (TxPDO-Map Status (TxPDO 4))

UINT16

RW

0x1A03 (6659dec)

Index 1C32 SM output parameter

Index

Name

Meaning

Data type

Flags

Default

1C32:0

SM output parameter

Synchronization parameters for the outputs

UINT8
BOOLEAN

RO

0x14 (20dec)

1C32:01

Sync mode

Current synchronization mode:

0: Free Run
1: Synchron with SM 2 Event
2: DC-Mode - Synchron with SYNC0 Event
3: DC-Mode - Synchron with SYNC1 Event

UINT16

RW

0x0001 (1dec)

1C32:02

Cycle time

Cycle time (in ns):

Free Run: Cycle time of the local timer

Synchron with SM 2 Event: Master cycle time

DC mode: SYNC0/SYNC1 Cycle Time

UINT32

RW

0x000AAE60 (700000dec)

1C32:03

Shift time

Time between SYNC0 event and output of the outputs (in ns, DC mode only)

UINT32

RW

0x00000000 (0dec)

1C32:04

Sync modes supported

Supported synchronization modes:

Bit 0 = 1: free run is supported
Bit 1 = 1: Synchron with SM 2 event is supported
Bit 2-3 = 01: DC mode is supported
Bit 4-5 = 10: Output shift with SYNC1 event (only DC mode)
Bit 14 = 1: dynamic times (measurement through writing of 0x1C32:08)

UINT16

RW

0x8007 (32775dec)

1C32:05

Minimum cycle time

Minimum cycle time (in ns)

UINT32

RW

0x000AAE60 (700000dec)

1C32:06

Calc and copy time

Minimum time between SYNC0 and SYNC1 event (in ns, DC mode only)

UINT32

RW

0x00000000 (0dec)

1C32:08

Command

0: Measurement of the local cycle time is stopped

1: Measurement of the local cycle time is started

0x1C32:033, 0x1C32:05, 0x1C32:06, 0x1C32:09, 0x1C33:03, 0x1C33:06, 0x1C33:09 are updated with the maximum measured values.
For a subsequent measurement the measured values are reset

UINT16

RW

0x0000 (0dec)

1C32:09

Delay time

Time between SYNC1 event and output of the outputs (in ns, DC mode only)

UINT32

RW

0x00000000 (0dec)

1C32:0B

SM event missed counter

Number of missed SM events in OPERATIONAL (DC mode only)

UINT166

RW

0x0000 (0dec)

1C32:0C

Cycle exceeded counter

Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early)

UINT16

RW

0x0000 (0dec)

1C32:0D

Shift too short counter

Number of occasions that the interval between SYNC0 and SYNC1 event was too short (DC mode only)

UINT16

RW

0x0000 (0dec)

1C32:20

Sync error

The synchronization was not correct in the last cycle (outputs were output too late; DC mode only)

BOOLEAN

RW

0x00 (0dec)

Index 1C33 SM input parameter

Index (hex)

Name

Meaning

Data type

Flags

Default

1C33:0

SM input parameter

Synchronization parameters for the inputs

UINT8

RO

0x14 (20dec)

1C33:01

Sync mode

Current synchronization mode:

0: Free Run
1: Synchron with SM 3 event (no outputs available)
2: DC - Synchron with SYNC0 Event
3: DC - Synchron with SYNC1 Event
34: Synchron with SM 2 Event (outputs available)

UINT16

RW

0x0022 (34dec)

1C33:02

Cycle time

as 0x1C32:02

UINT32

RW

0x000AAE60 (700000dec)

1C33:03

Shift time

Time between SYNC0 event and reading of the inputs (in ns, only DC mode)

UINT32

RW

0x00000000 (0dec)

1C33:04

Sync modes supported

Supported synchronization modes:

Bit 0: free run is supported

Bit 1: Synchron with SM 2 Event is supported (outputs available)

Bit 1: Synchron with SM 3 Event is supported (no outputs available)

Bit 2-3 = 01: DC mode is supported

Bit 4-5 = 01: input shift through local event (outputs available)

Bit 4-5 = 10: input shift with SYNC1 event (no outputs available)

Bit 14 = 1: dynamic times (measurement through writing of 0x1C32:08 or 0x1C33:08)

UINT16

RW

0x8007 (32775dec)

1C33:05

Minimum cycle time

as 0x1C32:05

UINT32

RW

0x000AAE60 (700000dec)

1C33:06

Calc and copy time

Time between reading of the inputs and availability of the inputs for the master (in ns, only DC mode)

UINT32

RW

0x00000000 (0dec)

1C33:08

Command

as 0x1C32:08

UINT16

RW

0x0000 (0dec)

1C33:09

Delay time

Time between SYNC1 event and reading of the inputs (in ns, only DC mode)

UINT32

RW

0x00000000 (0dec)

1C33:0B

SM event missed counter

as 0x1C32:0B

UINT16

RW

0x0000 (0dec)

1C33:0C

Cycle exceeded counter

as 0x1C32:0C

UINT16

RW

0x0000 (0dec)

1C33:0D

Shift too short counter

as 0x1C32:0D

UINT16

RW

0x0000 (0dec)

1C33:20

Sync error

as 0x1C32:20

BOOLEAN

RWW

0x00 (0dec)