Object description - standard objects
Index 1000 Device type
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1000:0 |
Device type |
Device type of the EtherCAT slave: the Lo-Word contains the CoE profile used (5001). The Hi-Word contains the module profile according to the modular device profile. |
UINT32 |
RO |
0x00001389 (5001dec) |
Index 1008 Device name
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1008:0 |
Device name |
Device name of the EtherCAT slave |
STRING |
RO |
EL1258 |
Index 1009 Hardware version
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1009:0 |
Hardware version |
Hardware version of the EtherCAT slave |
STRING |
RO |
|
Index 100A Software version
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
100A:0 |
Software version |
Firmware version of the EtherCAT slave |
STRING |
RO |
99 |
Index 1018 Identity
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1018:0 |
Identity |
Information for identifying the slave |
UINT8 |
RO |
0x04 (4dec) |
|
1018:01 |
Vendor ID |
Vendor ID of the EtherCAT slave |
UINT32 |
RO |
0x00000002 (2dec) |
|
1018:02 |
Product code |
Product code of the EtherCAT slave |
UINT32 |
RO |
0x04EA3052 (82456658dec) |
|
1018:03 |
Revision |
Revision number of the EtherCAT slave; the low word (bit 0-15) indicates the special terminal number, the high word (bit 16-31) refers to the device description |
UINT32 |
RO |
0x00000000 (0dec) |
|
1018:04 |
Serial number |
Serial number of the EtherCAT slave; the low byte (bit 0-7) of the low word contains the year of production, the high byte (bit 8-15) of the low word contains the week of production, the high word (bit 16-31) is 0 |
UINT32 |
RO |
0x00000000 (0dec) |
Index 10F0 Backup parameter handling
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
10F0:0 |
Backup parameter handling |
Information for standardized loading and saving of backup entries |
UINT8 |
RO |
0x01 (1dec) |
|
10F0:01 |
Checksum |
Checksum across all backup entries of the EtherCAT slave |
UINT32 |
RO |
0x00000000 (0dec) |
Index 1600 MTI RxPDO-Map Outputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1600:0 |
MTI RxPDO-Map Outputs Ch.1 |
PDO Mapping RxPDO 1 |
UINT8 |
RO |
0x04 (4dec) |
|
1600:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7000 (MTI outputs Ch.1), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7000:01, 1 |
|
1600:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1600:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7000 (MTI outputs Ch.1), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7000:11, 8 |
|
1600:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1601 MTI RxPDO-Map Outputs Ch.2
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1601:0 |
MTI RxPDO-Map Outputs Ch.2 |
PDO Mapping RxPDO 2 |
UINT8 |
RO |
0x04 (4dec) |
|
1601:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7010 (MTI outputs Ch.2), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7010:01, 1 |
|
1601:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1601:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7010 (MTI outputs Ch.2), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7010:11, 8 |
|
1601:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1602 MTI RxPDO-Map Outputs Ch.3
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1602:0 |
MTI RxPDO-Map Outputs Ch.3 |
PDO Mapping RxPDO 3 |
UINT8 |
RO |
0x04 (4dec) |
|
1602:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7020 (MTI outputs Ch.3), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7020:01, 1 |
|
1602:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1602:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7020 (MTI outputs Ch.3), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7020:11, 8 |
|
1602:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1603 MTI RxPDO-Map Outputs Ch.4
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1603:0 |
MTI RxPDO-Map Outputs Ch.4 |
PDO Mapping RxPDO 4 |
UINT8 |
RO |
0x04 (4dec) |
|
1603:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7030 (MTI outputs Ch.4), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7030:01, 1 |
|
1603:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1603:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7030 (MTI outputs Ch.4), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7030:11, 8 |
|
1603:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1604 MTI RxPDO-Map Outputs Ch.5
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1604:0 |
MTI RxPDO-Map Outputs Ch.5 |
PDO Mapping RxPDO 5 |
UINT8 |
RO |
0x04 (4dec) |
|
1604:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7040 (MTI outputs Ch.5), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7040:01, 1 |
|
1604:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1604:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7040 (MTI outputs Ch.5), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7040:11, 8 |
|
1604:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1605 MTI RxPDO-Map Outputs Ch.6
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1605:0 |
MTI RxPDO-Map Outputs Ch.6 |
PDO Mapping RxPDO 6 |
UINT8 |
RO |
0x04 (4dec) |
|
1605:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7050 (MTI outputs Ch.6), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7050:01, 1 |
|
1605:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1605:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7050 (MTI outputs Ch.6), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7050:11, 8 |
|
1605:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1606 MTI RxPDO-Map Outputs Ch.7
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1606:0 |
MTI RxPDO-Map Outputs Ch.7 |
PDO Mapping RxPDO 7 |
UINT8 |
RO |
0x04 (4dec) |
|
1606:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7060 (MTI outputs Ch.7), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7060:01, 1 |
|
1606:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1606:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7060 (MTI outputs Ch.7), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7060:11, 8 |
|
1606:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1607 MTI RxPDO-Map Outputs Ch.8
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1607:0 |
MTI RxPDO-Map Outputs Ch.8 |
PDO Mapping RxPDO 8 |
UINT8 |
RO |
0x04 (4dec) |
|
1607:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x7070 (MTI outputs Ch.8), entry 0x01 (Input buffer reset)) |
UINT32 |
RO |
0x7070:01, 1 |
|
1607:02 |
SubIndex 002 |
2. PDO Mapping entry (15 bits align) |
UINT32 |
RO |
0x0000:00, 15 |
|
1607:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x7070 (MTI outputs Ch.8), entry 0x11 (Input order counter)) |
UINT32 |
RO |
0x7070:11, 8 |
|
1607:04 |
SubIndex 004 |
4. PDO Mapping entry (8 bits align) |
UINT32 |
RO |
0x0000:00, 8 |
Index 1A00 MTI TxPDO-Map Inputs 10x Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A00:0 |
MTI TxPDO-Map Inputs 10x Ch.1 |
PDO Mapping TxPDO 1 |
UINT8 |
RO |
0x1C (28dec) |
|
1A00:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6001:01, 8 |
|
1A00:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6001:09, 1 |
|
1A00:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6001:0A, 1 |
|
1A00:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A00:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6001:0F, 2 |
|
1A00:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6001:11, 8 |
|
1A00:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6001:12, 8 |
|
1A00:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6001:21, 1 |
|
1A00:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6001:22, 1 |
|
1A00:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6001:23, 1 |
|
1A00:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6001:24, 1 |
|
1A00:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6001:25, 1 |
|
1A00:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6001:26, 1 |
|
1A00:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6001:27, 1 |
|
1A00:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6001:28, 1 |
|
1A00:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6001:29, 1 |
|
1A00:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6001:2A, 1 |
|
1A00:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A00:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6001:41, 32 |
|
1A00:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6001:42, 32 |
|
1A00:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6001:43, 32 |
|
1A00:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6001:44, 32 |
|
1A00:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6001:45, 32 |
|
1A00:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6001:46, 32 |
|
1A00:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6001:47, 32 |
|
1A00:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6001:48, 32 |
|
1A00:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6001:49, 32 |
|
1A00:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6001:4A, 32 |
Index 1A01 MTI TxPDO-Map Inputs 5x Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A01:0 |
MTI TxPDO-Map Inputs 5x Ch.1 |
PDO Mapping TxPDO 2 |
UINT8 |
RO |
0x12 (18dec) |
|
1A01:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6001:01, 8 |
|
1A01:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6001:09, 1 |
|
1A01:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6001:0A, 1 |
|
1A01:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A01:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6001:0F, 2 |
|
1A01:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6001:11, 8 |
|
1A01:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6001:12, 8 |
|
1A01:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6001:21, 1 |
|
1A01:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6001:22, 1 |
|
1A01:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6001:23, 1 |
|
1A01:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6001:24, 1 |
|
1A01:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6001:25, 1 |
|
1A01:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A01:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6001:41, 32 |
|
1A01:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6001:42, 32 |
|
1A01:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6001:43, 32 |
|
1A01:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6001:44, 32 |
|
1A01:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6001:45, 32 |
Index 1A02 MTI TxPDO-Map Inputs 2x Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A02:0 |
MTI TxPDO-Map Inputs 2x Ch.1 |
PDO Mapping TxPDO 3 |
UINT8 |
RO |
0x0C (12dec) |
|
1A02:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6001:01, 8 |
|
1A02:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6001:09, 1 |
|
1A02:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6001:0A, 1 |
|
1A02:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A02:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6001:0F, 2 |
|
1A02:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6001:11, 8 |
|
1A02:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6001:12, 8 |
|
1A02:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6001:21, 1 |
|
1A02:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6001:22, 1 |
|
1A02:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A02:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6001:41, 32 |
|
1A02:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6001:42, 32 |
Index 1A03 MTI TxPDO-Map Inputs 1x Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A03:0 |
MTI TxPDO-Map Inputs 1x Ch.1 |
PDO Mapping TxPDO 4 |
UINT8 |
RO |
0x0A (10dec) |
|
1A03:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6001:01, 8 |
|
1A03:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6001:09, 1 |
|
1A03:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6001:0A, 1 |
|
1A03:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A03:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6001:0F, 2 |
|
1A03:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6001:11, 8 |
|
1A03:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6001:12, 8 |
|
1A03:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6001:21, 1 |
|
1A03:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A03:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6001 (MTI inputs Ch.1), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6001:41, 32 |
Index 1A04 MTI TxPDO-Map Inputs 10x Ch.2
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A04:0 |
MTI TxPDO-Map Inputs 10x Ch.2 |
PDO Mapping TxPDO 5 |
UINT8 |
RO |
0x1C (28dec) |
|
1A04:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6011:01, 8 |
|
1A04:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6011:09, 1 |
|
1A04:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6011:0A, 1 |
|
1A04:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A04:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6011:0F, 2 |
|
1A04:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6011:11, 8 |
|
1A04:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6011:12, 8 |
|
1A04:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6011:21, 1 |
|
1A04:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6011:22, 1 |
|
1A04:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6011:23, 1 |
|
1A04:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6011:24, 1 |
|
1A04:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6011:25, 1 |
|
1A04:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6011:26, 1 |
|
1A04:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6011:27, 1 |
|
1A04:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6011:28, 1 |
|
1A04:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6011:29, 1 |
|
1A04:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6011:2A, 1 |
|
1A04:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A04:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6011:41, 32 |
|
1A04:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6011:42, 32 |
|
1A04:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6011:43, 32 |
|
1A04:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6011:44, 32 |
|
1A04:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6011:45, 32 |
|
1A04:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6011:46, 32 |
|
1A04:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6011:47, 32 |
|
1A04:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6011:48, 32 |
|
1A04:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6011:49, 32 |
|
1A04:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6011:4A, 32 |
Index 1A05 MTI TxPDO-Map Inputs 5x Ch.2
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A05:0 |
MTI TxPDO-Map Inputs 5x Ch.2 |
PDO Mapping TxPDO 6 |
UINT8 |
RO |
0x12 (18dec) |
|
1A05:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6011:01, 8 |
|
1A05:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6011:09, 1 |
|
1A05:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6011:0A, 1 |
|
1A05:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A05:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6011:0F, 2 |
|
1A05:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6011:11, 8 |
|
1A05:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6011:12, 8 |
|
1A05:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6011:21, 1 |
|
1A05:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6011:22, 1 |
|
1A05:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6011:23, 1 |
|
1A05:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6011:24, 1 |
|
1A05:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6011:25, 1 |
|
1A05:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A05:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6011:41, 32 |
|
1A05:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6011:42, 32 |
|
1A05:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6011:43, 32 |
|
1A05:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6011:44, 32 |
|
1A05:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6011:45, 32 |
Index 1A06 MTI TxPDO-Map Inputs 2x Ch.2
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A06:0 |
MTI TxPDO-Map Inputs 2x Ch.2 |
PDO Mapping TxPDO 7 |
UINT8 |
RO |
0x0C (12dec) |
|
1A06:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6011:01, 8 |
|
1A06:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6011:09, 1 |
|
1A06:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6011:0A, 1 |
|
1A06:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A06:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6011:0F, 2 |
|
1A06:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6011:11, 8 |
|
1A06:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6011:12, 8 |
|
1A06:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6011:21, 1 |
|
1A06:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6011:22, 1 |
|
1A06:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A06:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6011:41, 32 |
|
1A06:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6011:42, 32 |
Index 1A07 MTI TxPDO-Map Inputs 1x Ch.2
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A07:0 |
MTI TxPDO-Map Inputs 1x Ch.2 |
PDO Mapping TxPDO 8 |
UINT8 |
RO |
0x0A (10dec) |
|
1A07:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6011:01, 8 |
|
1A07:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6011:09, 1 |
|
1A07:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6011:0A, 1 |
|
1A07:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A07:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6011:0F, 2 |
|
1A07:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6011:11, 8 |
|
1A07:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6011:12, 8 |
|
1A07:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6011:21, 1 |
|
1A07:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A07:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6011 (MTI inputs Ch.2), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6011:41, 32 |
Index 1A08 MTI TxPDO-Map Inputs 10x Ch.3
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A08:0 |
MTI TxPDO-Map Inputs 10x Ch.3 |
PDO Mapping TxPDO 9 |
UINT8 |
RO |
0x1C (28dec) |
|
1A08:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6021:01, 8 |
|
1A08:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6021:09, 1 |
|
1A08:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6021:0A, 1 |
|
1A08:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A08:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6021:0F, 2 |
|
1A08:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6021:11, 8 |
|
1A08:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6021:12, 8 |
|
1A08:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6021:21, 1 |
|
1A08:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6021:22, 1 |
|
1A08:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6021:23, 1 |
|
1A08:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6021:24, 1 |
|
1A08:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6021:25, 1 |
|
1A08:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6021:26, 1 |
|
1A08:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6021:27, 1 |
|
1A08:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6021:28, 1 |
|
1A08:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6021:29, 1 |
|
1A08:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6021:2A, 1 |
|
1A08:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A08:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6021:41, 32 |
|
1A08:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6021:42, 32 |
|
1A08:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6021:43, 32 |
|
1A08:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6021:44, 32 |
|
1A08:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6021:45, 32 |
|
1A08:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6021:46, 32 |
|
1A08:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6021:47, 32 |
|
1A08:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6021:48, 32 |
|
1A08:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6021:49, 32 |
|
1A08:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6021:4A, 32 |
Index 1A09 MTI TxPDO-Map Inputs 5x Ch.3
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A09:0 |
MTI TxPDO-Map Inputs 5x Ch.3 |
PDO Mapping TxPDO 10 |
UINT8 |
RO |
0x12 (18dec) |
|
1A09:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6021:01, 8 |
|
1A09:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6021:09, 1 |
|
1A09:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6021:0A, 1 |
|
1A09:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A09:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6021:0F, 2 |
|
1A09:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6021:11, 8 |
|
1A09:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6021:12, 8 |
|
1A09:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6021:21, 1 |
|
1A09:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6021:22, 1 |
|
1A09:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6021:23, 1 |
|
1A09:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6021:24, 1 |
|
1A09:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6021:25, 1 |
|
1A09:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A09:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6021:41, 32 |
|
1A09:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6021:42, 32 |
|
1A09:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6021:43, 32 |
|
1A09:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6021:44, 32 |
|
1A09:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6021:45, 32 |
Index 1A0A MTI TxPDO-Map Inputs 2x Ch.3
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0A:0 |
MTI TxPDO-Map Inputs 2x Ch.3 |
PDO Mapping TxPDO 11 |
UINT8 |
RO |
0x0C (12dec) |
|
1A0A:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6021:01, 8 |
|
1A0A:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6021:09, 1 |
|
1A0A:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6021:0A, 1 |
|
1A0A:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A0A:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6021:0F, 2 |
|
1A0A:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6021:11, 8 |
|
1A0A:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6021:12, 8 |
|
1A0A:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6021:21, 1 |
|
1A0A:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6021:22, 1 |
|
1A0A:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A0A:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6021:41, 32 |
|
1A0A:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6021:42, 32 |
Index 1A0B MTI TxPDO-Map Inputs 1x Ch.3
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0B:0 |
MTI TxPDO-Map Inputs 1x Ch.3 |
PDO Mapping TxPDO 12 |
UINT8 |
RO |
0x0A (10dec) |
|
1A0B:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6021:01, 8 |
|
1A0B:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6021:09, 1 |
|
1A0B:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6021:0A, 1 |
|
1A0B:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A0B:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6021:0F, 2 |
|
1A0B:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6021:11, 8 |
|
1A0B:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6021:12, 8 |
|
1A0B:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6021:21, 1 |
|
1A0B:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A0B:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6021 (MTI inputs Ch.3), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6021:41, 32 |
Index 1A0C MTI TxPDO-Map Inputs 10x Ch.4
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0C:0 |
MTI TxPDO-Map Inputs 10x Ch.4 |
PDO Mapping TxPDO 13 |
UINT8 |
RO |
0x1C (28dec) |
|
1A0C:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6031:01, 8 |
|
1A0C:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6031:09, 1 |
|
1A0C:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6031:0A, 1 |
|
1A0C:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A0C:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6031:0F, 2 |
|
1A0C:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6031:11, 8 |
|
1A0C:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6031:12, 8 |
|
1A0C:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6031:21, 1 |
|
1A0C:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6031:22, 1 |
|
1A0C:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6031:23, 1 |
|
1A0C:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6031:24, 1 |
|
1A0C:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6031:25, 1 |
|
1A0C:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6031:26, 1 |
|
1A0C:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6031:27, 1 |
|
1A0C:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6031:28, 1 |
|
1A0C:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6031:29, 1 |
|
1A0C:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6031:2A, 1 |
|
1A0C:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A0C:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6031:41, 32 |
|
1A0C:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6031:42, 32 |
|
1A0C:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6031:43, 32 |
|
1A0C:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6031:44, 32 |
|
1A0C:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6031:45, 32 |
|
1A0C:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6031:46, 32 |
|
1A0C:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6031:47, 32 |
|
1A0C:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6031:48, 32 |
|
1A0C:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6031:49, 32 |
|
1A0C:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6031:4A, 32 |
Index 1A0D MTI TxPDO-Map Inputs 5x Ch.4
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0D:0 |
MTI TxPDO-Map Inputs 5x Ch.4 |
PDO Mapping TxPDO 14 |
UINT8 |
RO |
0x12 (18dec) |
|
1A0D:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6031:01, 8 |
|
1A0D:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6031:09, 1 |
|
1A0D:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6031:0A, 1 |
|
1A0D:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A0D:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6031:0F, 2 |
|
1A0D:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6031:11, 8 |
|
1A0D:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6031:12, 8 |
|
1A0D:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6031:21, 1 |
|
1A0D:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6031:22, 1 |
|
1A0D:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6031:23, 1 |
|
1A0D:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6031:24, 1 |
|
1A0D:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6031:25, 1 |
|
1A0D:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A0D:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6031:41, 32 |
|
1A0D:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6031:42, 32 |
|
1A0D:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6031:43, 32 |
|
1A0D:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6031:44, 32 |
|
1A0D:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6031:45, 32 |
Index 1A0E MTI TxPDO-Map Inputs 2x Ch.4
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0E:0 |
MTI TxPDO-Map Inputs 2x Ch.4 |
PDO Mapping TxPDO 15 |
UINT8 |
RO |
0x0C (12dec) |
|
1A0E:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6031:01, 8 |
|
1A0E:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6031:09, 1 |
|
1A0E:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6031:0A, 1 |
|
1A0E:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A0E:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6031:0F, 2 |
|
1A0E:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6031:11, 8 |
|
1A0E:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6031:12, 8 |
|
1A0E:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6031:21, 1 |
|
1A0E:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6031:22, 1 |
|
1A0E:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A0E:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6031:41, 32 |
|
1A0E:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6031:42, 32 |
Index 1A0F MTI TxPDO-Map Inputs 1x Ch.4
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A0F:0 |
MTI TxPDO-Map Inputs 1x Ch.4 |
PDO Mapping TxPDO 16 |
UINT8 |
RO |
0x0A (10dec) |
|
1A0F:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6031:01, 8 |
|
1A0F:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6031:09, 1 |
|
1A0F:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6031:0A, 1 |
|
1A0F:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A0F:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6031:0F, 2 |
|
1A0F:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6031:11, 8 |
|
1A0F:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6031:12, 8 |
|
1A0F:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6031:21, 1 |
|
1A0F:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A0F:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6031 (MTI inputs Ch.4), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6031:41, 32 |
Index 1A10 MTI TxPDO-Map Inputs 10x Ch.5
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A10:0 |
MTI TxPDO-Map Inputs 10x Ch.5 |
PDO Mapping TxPDO 17 |
UINT8 |
RO |
0x1C (28dec) |
|
1A10:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6041:01, 8 |
|
1A10:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6041:09, 1 |
|
1A10:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6041:0A, 1 |
|
1A10:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A10:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6041:0F, 2 |
|
1A10:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6041:11, 8 |
|
1A10:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6041:12, 8 |
|
1A10:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6041:21, 1 |
|
1A10:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6041:22, 1 |
|
1A10:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6041:23, 1 |
|
1A10:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6041:24, 1 |
|
1A10:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6041:25, 1 |
|
1A10:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6041:26, 1 |
|
1A10:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6041:27, 1 |
|
1A10:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6041:28, 1 |
|
1A10:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6041:29, 1 |
|
1A10:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6041:2A, 1 |
|
1A10:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A10:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6041:41, 32 |
|
1A10:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6041:42, 32 |
|
1A10:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6041:43, 32 |
|
1A10:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6041:44, 32 |
|
1A10:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6041:45, 32 |
|
1A10:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6041:46, 32 |
|
1A10:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6041:47, 32 |
|
1A10:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6041:48, 32 |
|
1A10:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6041:49, 32 |
|
1A10:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6041:4A, 32 |
Index 1A11 MTI TxPDO-Map Inputs 5x Ch.5
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A11:0 |
MTI TxPDO-Map Inputs 5x Ch.5 |
PDO Mapping TxPDO 18 |
UINT8 |
RO |
0x12 (18dec) |
|
1A11:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6041:01, 8 |
|
1A11:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6041:09, 1 |
|
1A11:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6041:0A, 1 |
|
1A11:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A11:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6041:0F, 2 |
|
1A11:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6041:11, 8 |
|
1A11:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6041:12, 8 |
|
1A11:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6041:21, 1 |
|
1A11:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6041:22, 1 |
|
1A11:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6041:23, 1 |
|
1A11:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6041:24, 1 |
|
1A11:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6041:25, 1 |
|
1A11:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A11:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6041:41, 32 |
|
1A11:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6041:42, 32 |
|
1A11:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6041:43, 32 |
|
1A11:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6041:44, 32 |
|
1A11:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6041:45, 32 |
Index 1A12 MTI TxPDO-Map Inputs 2x Ch.5
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A12:0 |
MTI TxPDO-Map Inputs 2x Ch.5 |
PDO Mapping TxPDO 19 |
UINT8 |
RO |
0x0C (12dec) |
|
1A12:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6041:01, 8 |
|
1A12:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6041:09, 1 |
|
1A12:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6041:0A, 1 |
|
1A12:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A12:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6041:0F, 2 |
|
1A12:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6041:11, 8 |
|
1A12:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6041:12, 8 |
|
1A12:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6041:21, 1 |
|
1A12:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6041:22, 1 |
|
1A12:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A12:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6041:41, 32 |
|
1A12:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6041:42, 32 |
Index 1A13 MTI TxPDO-Map Inputs 1x Ch.5
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A13:0 |
MTI TxPDO-Map Inputs 1x Ch.5 |
PDO Mapping TxPDO 20 |
UINT8 |
RO |
0x0A (10dec) |
|
1A13:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6041:01, 8 |
|
1A13:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6041:09, 1 |
|
1A13:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6041:0A, 1 |
|
1A13:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A13:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6041:0F, 2 |
|
1A13:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6041:11, 8 |
|
1A13:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6041:12, 8 |
|
1A13:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6041:21, 1 |
|
1A13:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A13:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6041 (MTI inputs Ch.5), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6041:41, 32 |
Index 1A14 MTI TxPDO-Map Inputs 10x Ch.6
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A14:0 |
MTI TxPDO-Map Inputs 10x Ch.6 |
PDO Mapping TxPDO 21 |
UINT8 |
RO |
0x1C (28dec) |
|
1A14:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6051:01, 8 |
|
1A14:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6051:09, 1 |
|
1A14:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6051:0A, 1 |
|
1A14:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A14:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6051:0F, 2 |
|
1A14:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6051:11, 8 |
|
1A14:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6051:12, 8 |
|
1A14:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6051:21, 1 |
|
1A14:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6051:22, 1 |
|
1A14:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6051:23, 1 |
|
1A14:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6051:24, 1 |
|
1A14:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6051:25, 1 |
|
1A14:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6051:26, 1 |
|
1A14:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6051:27, 1 |
|
1A14:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6051:28, 1 |
|
1A14:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6051:29, 1 |
|
1A14:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6051:2A, 1 |
|
1A14:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A14:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6051:41, 32 |
|
1A14:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6051:42, 32 |
|
1A14:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6051:43, 32 |
|
1A14:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6051:44, 32 |
|
1A14:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6051:45, 32 |
|
1A14:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6051:46, 32 |
|
1A14:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6051:47, 32 |
|
1A14:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6051:48, 32 |
|
1A14:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6051:49, 32 |
|
1A14:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6051:4A, 32 |
Index 1A15 MTI TxPDO-Map Inputs 5x Ch.6
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A15:0 |
MTI TxPDO-Map Inputs 5x Ch.6 |
PDO Mapping TxPDO 22 |
UINT8 |
RO |
0x12 (18dec) |
|
1A15:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6051:01, 8 |
|
1A15:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6051:09, 1 |
|
1A15:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6051:0A, 1 |
|
1A15:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A15:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6051:0F, 2 |
|
1A15:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6051:11, 8 |
|
1A15:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6051:12, 8 |
|
1A15:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6051:21, 1 |
|
1A15:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6051:22, 1 |
|
1A15:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6051:23, 1 |
|
1A15:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6051:24, 1 |
|
1A15:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6051:25, 1 |
|
1A15:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A15:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6051:41, 32 |
|
1A15:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6051:42, 32 |
|
1A15:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6051:43, 32 |
|
1A15:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6051:44, 32 |
|
1A15:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6051:45, 32 |
Index 1A16 MTI TxPDO-Map Inputs 2x Ch.6
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A16:0 |
MTI TxPDO-Map Inputs 2x Ch.6 |
PDO Mapping TxPDO 23 |
UINT8 |
RO |
0x0C (12dec) |
|
1A16:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6051:01, 8 |
|
1A16:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6051:09, 1 |
|
1A16:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6051:0A, 1 |
|
1A16:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A16:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6051:0F, 2 |
|
1A16:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6051:11, 8 |
|
1A16:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6051:12, 8 |
|
1A16:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6051:21, 1 |
|
1A16:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6051:22, 1 |
|
1A16:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A16:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6051:41, 32 |
|
1A16:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6051:42, 32 |
Index 1A17 MTI TxPDO-Map Inputs 1x Ch.6
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A17:0 |
MTI TxPDO-Map Inputs 1x Ch.6 |
PDO Mapping TxPDO 24 |
UINT8 |
RO |
0x0A (10dec) |
|
1A17:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6051:01, 8 |
|
1A17:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6051:09, 1 |
|
1A17:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6051:0A, 1 |
|
1A17:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A17:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6051:0F, 2 |
|
1A17:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6051:11, 8 |
|
1A17:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6051:12, 8 |
|
1A17:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6051:21, 1 |
|
1A17:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A17:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6051 (MTI inputs Ch.6), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6051:41, 32 |
Index 1A18 MTI TxPDO-Map Inputs 10x Ch.7
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A18:0 |
MTI TxPDO-Map Inputs 10x Ch.7 |
PDO Mapping TxPDO 25 |
UINT8 |
RO |
0x1C (28dec) |
|
1A18:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6061:01, 8 |
|
1A18:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6061:09, 1 |
|
1A18:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6061:0A, 1 |
|
1A18:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A18:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6061:0F, 2 |
|
1A18:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6061:11, 8 |
|
1A18:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6061:12, 8 |
|
1A18:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6061:21, 1 |
|
1A18:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6061:22, 1 |
|
1A18:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6061:23, 1 |
|
1A18:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6061:24, 1 |
|
1A18:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6061:25, 1 |
|
1A18:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6061:26, 1 |
|
1A18:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6061:27, 1 |
|
1A18:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6061:28, 1 |
|
1A18:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6061:29, 1 |
|
1A18:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6061:2A, 1 |
|
1A18:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A18:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6061:41, 32 |
|
1A18:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6061:42, 32 |
|
1A18:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6061:43, 32 |
|
1A18:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6061:44, 32 |
|
1A18:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6061:45, 32 |
|
1A18:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6061:46, 32 |
|
1A18:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6061:47, 32 |
|
1A18:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6061:48, 32 |
|
1A18:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6061:49, 32 |
|
1A18:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6061:4A, 32 |
Index 1A19 MTI TxPDO-Map Inputs 5x Ch.7
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A19:0 |
MTI TxPDO-Map Inputs 5x Ch.7 |
PDO Mapping TxPDO 26 |
UINT8 |
RO |
0x12 (18dec) |
|
1A19:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6061:01, 8 |
|
1A19:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6061:09, 1 |
|
1A19:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6061:0A, 1 |
|
1A19:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A19:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6061:0F, 2 |
|
1A19:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6061:11, 8 |
|
1A19:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6061:12, 8 |
|
1A19:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6061:21, 1 |
|
1A19:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6061:22, 1 |
|
1A19:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6061:23, 1 |
|
1A19:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6061:24, 1 |
|
1A19:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6061:25, 1 |
|
1A19:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A19:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6061:41, 32 |
|
1A19:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6061:42, 32 |
|
1A19:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6061:43, 32 |
|
1A19:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6061:44, 32 |
|
1A19:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6061:45, 32 |
Index 1A1A MTI TxPDO-Map Inputs 2x Ch.7
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A1A:0 |
MTI TxPDO-Map Inputs 2x Ch.7 |
PDO Mapping TxPDO 27 |
UINT8 |
RO |
0x0C (12dec) |
|
1A1A:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6061:01, 8 |
|
1A1A:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6061:09, 1 |
|
1A1A:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6061:0A, 1 |
|
1A1A:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A1A:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6061:0F, 2 |
|
1A1A:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6061:11, 8 |
|
1A1A:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6061:12, 8 |
|
1A1A:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6061:21, 1 |
|
1A1A:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6061:22, 1 |
|
1A1A:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A1A:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6061:41, 32 |
|
1A1A:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6061:42, 32 |
Index 1A1B MTI TxPDO-Map Inputs 1x Ch.7
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A1B:0 |
MTI TxPDO-Map Inputs 1x Ch.7 |
PDO Mapping TxPDO 28 |
UINT8 |
RO |
0x0A (10dec) |
|
1A1B:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6061:01, 8 |
|
1A1B:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6061:09, 1 |
|
1A1B:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6061:0A, 1 |
|
1A1B:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A1B:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6061:0F, 2 |
|
1A1B:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6061:11, 8 |
|
1A1B:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6061:12, 8 |
|
1A1B:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6061:21, 1 |
|
1A1B:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A1B:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6061 (MTI inputs Ch.7), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6061:41, 32 |
Index 1A1C MTI TxPDO-Map Inputs 10x Ch.8
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A1C:0 |
MTI TxPDO-Map Inputs 10x Ch.8 |
PDO Mapping TxPDO 29 |
UINT8 |
RO |
0x1C (28dec) |
|
1A1C:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6071:01, 8 |
|
1A1C:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6071:09, 1 |
|
1A1C:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6071:0A, 1 |
|
1A1C:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A1C:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6071:0F, 2 |
|
1A1C:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6071:11, 8 |
|
1A1C:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6071:12, 8 |
|
1A1C:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6071:21, 1 |
|
1A1C:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6071:22, 1 |
|
1A1C:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6071:23, 1 |
|
1A1C:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6071:24, 1 |
|
1A1C:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6071:25, 1 |
|
1A1C:0D |
SubIndex 013 |
13. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x26 (Input event state 6)) |
UINT32 |
RO |
0x6071:26, 1 |
|
1A1C:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x27 (Input event state 7)) |
UINT32 |
RO |
0x6071:27, 1 |
|
1A1C:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x28 (Input event state 8)) |
UINT32 |
RO |
0x6071:28, 1 |
|
1A1C:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x29 (Input event state 9)) |
UINT32 |
RO |
0x6071:29, 1 |
|
1A1C:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x2A (Input event state 10)) |
UINT32 |
RO |
0x6071:2A, 1 |
|
1A1C:12 |
SubIndex 018 |
18. PDO Mapping entry (22 bits align) |
UINT32 |
RO |
0x0000:00, 22 |
|
1A1C:13 |
SubIndex 019 |
19. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6071:41, 32 |
|
1A1C:14 |
SubIndex 020 |
20. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6071:42, 32 |
|
1A1C:15 |
SubIndex 021 |
21. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6071:43, 32 |
|
1A1C:16 |
SubIndex 022 |
22. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6071:44, 32 |
|
1A1C:17 |
SubIndex 023 |
23. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6071:45, 32 |
|
1A1C:18 |
SubIndex 024 |
24. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x46 (Input event time 6)) |
UINT32 |
RO |
0x6071:46, 32 |
|
1A1C:19 |
SubIndex 025 |
25. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x47 (Input event time 7)) |
UINT32 |
RO |
0x6071:47, 32 |
|
1A1C:1A |
SubIndex 026 |
26. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x48 (Input event time 8)) |
UINT32 |
RO |
0x6071:48, 32 |
|
1A1C:1B |
SubIndex 027 |
27. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x49 (Input event time 9)) |
UINT32 |
RO |
0x6071:49, 32 |
|
1A1C:1C |
SubIndex 028 |
28. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x4A (Input event time 10)) |
UINT32 |
RO |
0x6071:4A, 32 |
Index 1A1D MTI TxPDO-Map Inputs 5x Ch.8
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A1D:0 |
MTI TxPDO-Map Inputs 5x Ch.8 |
PDO Mapping TxPDO 30 |
UINT8 |
RO |
0x12 (18dec) |
|
1A1D:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6071:01, 8 |
|
1A1D:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6071:09, 1 |
|
1A1D:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6071:0A, 1 |
|
1A1D:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A1D:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6071:0F, 2 |
|
1A1D:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6071:11, 8 |
|
1A1D:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6071:12, 8 |
|
1A1D:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6071:21, 1 |
|
1A1D:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6071:22, 1 |
|
1A1D:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x23 (Input event state 3)) |
UINT32 |
RO |
0x6071:23, 1 |
|
1A1D:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x24 (Input event state 4)) |
UINT32 |
RO |
0x6071:24, 1 |
|
1A1D:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x25 (Input event state 5)) |
UINT32 |
RO |
0x6071:25, 1 |
|
1A1D:0D |
SubIndex 013 |
13. PDO Mapping entry (27 bits align) |
UINT32 |
RO |
0x0000:00, 27 |
|
1A1D:0E |
SubIndex 014 |
14. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6071:41, 32 |
|
1A1D:0F |
SubIndex 015 |
15. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6071:42, 32 |
|
1A1D:10 |
SubIndex 016 |
16. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x43 (Input event time 3)) |
UINT32 |
RO |
0x6071:43, 32 |
|
1A1D:11 |
SubIndex 017 |
17. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x44 (Input event time 4)) |
UINT32 |
RO |
0x6071:44, 32 |
|
1A1D:12 |
SubIndex 018 |
18. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x45 (Input event time 5)) |
UINT32 |
RO |
0x6071:45, 32 |
Index 1A1E MTI TxPDO-Map Inputs 2x Ch.8
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A1E:0 |
MTI TxPDO-Map Inputs 2x Ch.8 |
PDO Mapping TxPDO 31 |
UINT8 |
RO |
0x0C (12dec) |
|
1A1E:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6071:01, 8 |
|
1A1E:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6071:09, 1 |
|
1A1E:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6071:0A, 1 |
|
1A1E:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A1E:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6071:0F, 2 |
|
1A1E:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6071:11, 8 |
|
1A1E:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6071:12, 8 |
|
1A1E:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6071:21, 1 |
|
1A1E:09 |
SubIndex 009 |
9. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x22 (Input event state 2)) |
UINT32 |
RO |
0x6071:22, 1 |
|
1A1E:0A |
SubIndex 010 |
10. PDO Mapping entry (30 bits align) |
UINT32 |
RO |
0x0000:00, 30 |
|
1A1E:0B |
SubIndex 011 |
11. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6071:41, 32 |
|
1A1E:0C |
SubIndex 012 |
12. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x42 (Input event time 2)) |
UINT32 |
RO |
0x6071:42, 32 |
Index 1A1F MTI TxPDO-Map Inputs 1x Ch.8
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A1F:0 |
MTI TxPDO-Map Inputs 1x Ch.8 |
PDO Mapping TxPDO 32 |
UINT8 |
RO |
0x0A (10dec) |
|
1A1F:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x01 (No of input events)) |
UINT32 |
RO |
0x6071:01, 8 |
|
1A1F:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x09 (Input state)) |
UINT32 |
RO |
0x6071:09, 1 |
|
1A1F:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0A (Input buffer overflow)) |
UINT32 |
RO |
0x6071:0A, 1 |
|
1A1F:04 |
SubIndex 004 |
4. PDO Mapping entry (4 bits align) |
UINT32 |
RO |
0x0000:00, 4 |
|
1A1F:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x0F (Input cycle counter)) |
UINT32 |
RO |
0x6071:0F, 2 |
|
1A1F:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x11 (Events in input buffer)) |
UINT32 |
RO |
0x6071:11, 8 |
|
1A1F:07 |
SubIndex 007 |
7. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x12 (Input order feedback)) |
UINT32 |
RO |
0x6071:12, 8 |
|
1A1F:08 |
SubIndex 008 |
8. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x21 (Input event state 1)) |
UINT32 |
RO |
0x6071:21, 1 |
|
1A1F:09 |
SubIndex 009 |
9. PDO Mapping entry (31 bits align) |
UINT32 |
RO |
0x0000:00, 31 |
|
1A1F:0A |
SubIndex 010 |
10. PDO Mapping entry (object 0x6071 (MTI inputs Ch.8), entry 0x41 (Input event time 1)) |
UINT32 |
RO |
0x6071:41, 32 |
Index 1A20 TSI TxPDO-Map Inputs Ch.1
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A20:0 |
TSI TxPDO-Map Inputs Ch.1 |
PDO Mapping TxPDO 33 |
UINT8 |
RO |
0x06 (6dec) |
|
1A20:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6080 (TSI Inputs Ch.1), entry 0x01 (Input)) |
UINT32 |
RO |
0x6080:01, 1 |
|
1A20:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A20:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6080 (TSI Inputs Ch.1), entry 0x09 (Status)) |
UINT32 |
RO |
0x6080:09, 8 |
|
1A20:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A20:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6080 (TSI Inputs Ch.1), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x6080:41, 64 |
|
1A20:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6080 (TSI Inputs Ch.1), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x6080:42, 64 |
Index 1A21 TSI TxPDO-Map Inputs Ch.2
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A21:0 |
TSI TxPDO-Map Inputs Ch.2 |
PDO Mapping TxPDO 34 |
UINT8 |
RO |
0x06 (6dec) |
|
1A21:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x6090 (TSI Inputs Ch.2), entry 0x01 (Input)) |
UINT32 |
RO |
0x6090:01, 1 |
|
1A21:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A21:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x6090 (TSI Inputs Ch.2), entry 0x09 (Status)) |
UINT32 |
RO |
0x6090:09, 8 |
|
1A21:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A21:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x6090 (TSI Inputs Ch.2), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x6090:41, 64 |
|
1A21:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x6090 (TSI Inputs Ch.2), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x6090:42, 64 |
Index 1A22 TSI TxPDO-Map Inputs Ch.3
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A22:0 |
TSI TxPDO-Map Inputs Ch.3 |
PDO Mapping TxPDO 35 |
UINT8 |
RO |
0x06 (6dec) |
|
1A22:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x60A0 (TSI Inputs Ch.3), entry 0x01 (Input)) |
UINT32 |
RO |
0x60A0:01, 1 |
|
1A22:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A22:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x60A0 (TSI Inputs Ch.3), entry 0x09 (Status)) |
UINT32 |
RO |
0x60A0:09, 8 |
|
1A22:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A22:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x60A0 (TSI Inputs Ch.3), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x60A0:41, 64 |
|
1A22:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x60A0 (TSI Inputs Ch.3), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x60A0:42, 64 |
Index 1A23 TSI TxPDO-Map Inputs Ch.4
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A23:0 |
TSI TxPDO-Map Inputs Ch.4 |
PDO Mapping TxPDO 36 |
UINT8 |
RO |
0x06 (6dec) |
|
1A23:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x60B0 (TSI Inputs Ch.4), entry 0x01 (Input)) |
UINT32 |
RO |
0x60B0:01, 1 |
|
1A23:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A23:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x60B0 (TSI Inputs Ch.4), entry 0x09 (Status)) |
UINT32 |
RO |
0x60B0:09, 8 |
|
1A23:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A23:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x60B0 (TSI Inputs Ch.4), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x60B0:41, 64 |
|
1A23:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x60B0 (TSI Inputs Ch.4), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x60B0:42, 64 |
Index 1A24 TSI TxPDO-Map Inputs Ch.5
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A24:0 |
TSI TxPDO-Map Inputs Ch.5 |
PDO Mapping TxPDO 37 |
UINT8 |
RO |
0x06 (6dec) |
|
1A24:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x60C0 (TSI Inputs Ch.5), entry 0x01 (Input)) |
UINT32 |
RO |
0x60C0:01, 1 |
|
1A24:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A24:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x60C0 (TSI Inputs Ch.5), entry 0x09 (Status)) |
UINT32 |
RO |
0x60C0:09, 8 |
|
1A24:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A24:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x60C0 (TSI Inputs Ch.5), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x60C0:41, 64 |
|
1A24:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x60C0 (TSI Inputs Ch.5), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x60C0:42, 64 |
Index 1A25 TSI TxPDO-Map Inputs Ch.6
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A25:0 |
TSI TxPDO-Map Inputs Ch.6 |
PDO Mapping TxPDO 38 |
UINT8 |
RO |
0x06 (6dec) |
|
1A25:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x60D0 (TSI Inputs Ch.6), entry 0x01 (Input)) |
UINT32 |
RO |
0x60D0:01, 1 |
|
1A25:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A25:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x60D0 (TSI Inputs Ch.6), entry 0x09 (Status)) |
UINT32 |
RO |
0x60D0:09, 8 |
|
1A25:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A25:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x60D0 (TSI Inputs Ch.6), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x60D0:41, 64 |
|
1A25:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x60D0 (TSI Inputs Ch.6), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x60D0:42, 64 |
Index 1A26 TSI TxPDO-Map Inputs Ch.7
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A26:0 |
TSI TxPDO-Map Inputs Ch.7 |
PDO Mapping TxPDO 39 |
UINT8 |
RO |
0x06 (6dec) |
|
1A26:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x60E0 (TSI Inputs Ch.7), entry 0x01 (Input)) |
UINT32 |
RO |
0x60E0:01, 1 |
|
1A26:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A26:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x60E0 (TSI Inputs Ch.7), entry 0x09 (Status)) |
UINT32 |
RO |
0x60E0:09, 8 |
|
1A26:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A26:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x60E0 (TSI Inputs Ch.7), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x60E0:41, 64 |
|
1A26:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x60E0 (TSI Inputs Ch.7), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x60E0:42, 64 |
Index 1A27 TSI TxPDO-Map Inputs Ch.8
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A27:0 |
TSI TxPDO-Map Inputs Ch.8 |
PDO Mapping TxPDO 40 |
UINT8 |
RO |
0x06 (6dec) |
|
1A27:01 |
SubIndex 001 |
1. PDO Mapping entry (object 0x60F0 (TSI Inputs Ch.8), entry 0x01 (Input)) |
UINT32 |
RO |
0x60F0:01, 1 |
|
1A27:02 |
SubIndex 002 |
2. PDO Mapping entry (7 bits align) |
UINT32 |
RO |
0x0000:00, 7 |
|
1A27:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0x60F0 (TSI Inputs Ch.8), entry 0x09 (Status)) |
UINT32 |
RO |
0x60F0:09, 8 |
|
1A27:04 |
SubIndex 004 |
4. PDO Mapping entry (48 bits align) |
UINT32 |
RO |
0x0000:00, 48 |
|
1A27:05 |
SubIndex 005 |
5. PDO Mapping entry (object 0x60F0 (TSI Inputs Ch.8), entry 0x41 (LatchPos)) |
UINT32 |
RO |
0x60F0:41, 64 |
|
1A27:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0x60F0 (TSI Inputs Ch.8), entry 0x42 (LatchNeg)) |
UINT32 |
RO |
0x60F0:42, 64 |
Index 1A28 DEV TxPDO-Map Inputs Device
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A28:0 |
DEV TxPDO-Map Inputs Device |
PDO Mapping TxPDO 41 |
UINT8 |
RO |
0x06 (6dec) |
|
1A28:01 |
SubIndex 001 |
1. PDO Mapping entry (1 bits align) |
UINT32 |
RO |
0x0000:00, 1 |
|
1A28:02 |
SubIndex 002 |
2. PDO Mapping entry (object 0xF611 (DEV Inputs), entry 0x02 (Undervoltage Up)) |
UINT32 |
RO |
0xF611:02, 1 |
|
1A28:03 |
SubIndex 003 |
3. PDO Mapping entry (object 0xF611 (DEV Inputs), entry 0x03 (Overtemperature)) |
UINT32 |
RO |
0xF611:03, 1 |
|
1A28:04 |
SubIndex 004 |
4. PDO Mapping entry (object 0xF611 (DEV Inputs), entry 0x04 (Checksum error)) |
UINT32 |
RO |
0xF611:04, 1 |
|
1A28:05 |
SubIndex 005 |
5. PDO Mapping entry (60 bits align) |
UINT32 |
RO |
0x0000:00, 60 |
|
1A28:06 |
SubIndex 006 |
6. PDO Mapping entry (object 0xF611 (DEV Inputs), entry 0x21 (SysTime)) |
UINT32 |
RO |
0xF611:21, 64 |
Index 1C00Sync manager type
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C00:0 |
Sync manager type |
Using the sync managers |
UINT8 |
RO |
0x04 (4dec) |
|
1C00:01 |
SubIndex 001 |
Sync-Manager Type Channel 1: Mailbox Write |
UINT8 |
RO |
0x01 (1dec) |
|
1C00:02 |
SubIndex 002 |
Sync-Manager Type Channel 2: Mailbox Read |
UINT8 |
RO |
0x02 (2dec) |
|
1C00:03 |
SubIndex 003 |
Sync-Manager Type Channel 3: Process Data Write (Outputs) |
UINT8 |
RO |
0x03 (3dec) |
|
1C00:04 |
SubIndex 004 |
Sync-Manager Type Channel 4: Process Data Read (Inputs) |
UINT8 |
RO |
0x04 (4dec) |
Index 1C12 RxPDO assign
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C12:0 |
RxPDO assign |
PDO Assign Outputs |
UINT8 |
RW |
0x08 (8dec) |
|
1C12:01 |
SubIndex 001 |
1. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1600 (5632dec) |
|
1C12:02 |
SubIndex 002 |
2. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1601 (5633dec) |
|
1C12:03 |
SubIndex 003 |
3. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1602 (5634dec) |
|
1C12:04 |
SubIndex 004 |
4. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1603 (5635dec) |
|
1C12:05 |
SubIndex 005 |
5. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1604 (5636dec) |
|
1C12:06 |
SubIndex 006 |
6. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1605 (5637dec) |
|
1C12:07 |
SubIndex 007 |
7. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1606 (5638dec) |
|
1C12:08 |
SubIndex 008 |
8. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1607 (5639dec) |
Index 1C13 TxPDO assign
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C13:0 |
TxPDO assign |
PDO Assign Inputs |
UINT8 |
RW |
0x08 (8dec) |
|
1C13:01 |
SubIndex 001 |
1. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A00 (6656dec) |
|
1C13:02 |
SubIndex 002 |
2. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A04 (6660dec) |
|
1C13:03 |
SubIndex 003 |
3. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A08 (6664dec) |
|
1C13:04 |
SubIndex 004 |
4. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A0C (6668dec) |
|
1C13:05 |
SubIndex 005 |
5. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A10 (6672dec) |
|
1C13:06 |
SubIndex 006 |
6. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A14 (6676dec) |
|
1C13:07 |
SubIndex 007 |
7. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A18 (6680dec) |
|
1C13:08 |
SubIndex 008 |
8. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A1C (6684dec) |
|
1C13:09 |
SubIndex 009 |
9. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:0A |
SubIndex 010 |
10. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:0B |
SubIndex 011 |
11. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:0C |
SubIndex 012 |
12. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:0D |
SubIndex 013 |
13. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:0E |
SubIndex 014 |
14. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:0F |
SubIndex 015 |
15. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:10 |
SubIndex 016 |
16. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:11 |
SubIndex 017 |
17. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:12 |
SubIndex 018 |
18. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:13 |
SubIndex 019 |
19. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:14 |
SubIndex 020 |
20. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:15 |
SubIndex 021 |
21. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
Index 1C13 TxPDO assign
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C13:16 |
SubIndex 022 |
22. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:17 |
SubIndex 023 |
23. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:18 |
SubIndex 024 |
24. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:19 |
SubIndex 025 |
25. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:1A |
SubIndex 026 |
26. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:1B |
SubIndex 027 |
27. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:1C |
SubIndex 028 |
28. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:1D |
SubIndex 029 |
29. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:1E |
SubIndex 030 |
30. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:1F |
SubIndex 031 |
31. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:20 |
SubIndex 032 |
32. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:21 |
SubIndex 033 |
33. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:22 |
SubIndex 034 |
34. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:23 |
SubIndex 035 |
35. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:24 |
SubIndex 036 |
36. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:25 |
SubIndex 037 |
37. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:26 |
SubIndex 038 |
38. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:27 |
SubIndex 039 |
39. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:28 |
SubIndex 040 |
40. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
|
1C13:29 |
SubIndex 041 |
41. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x0000 (0dec) |
Index 1C32 SM output parameter
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C32:0 |
SM output parameter |
Synchronization parameters for the outputs |
UINT8 |
RO |
0x20 (32dec) |
|
1C32:01 |
Sync mode |
Current synchronization mode:
|
UINT16 |
RW |
0x0000 (0dec) |
|
1C32:02 |
Cycle time |
Cycle time (in ns):
|
UINT32 |
RW |
0x000C3500 (800000dec) |
|
1C32:03 |
Shift time |
Time between SYNC0 event and output of the outputs (in ns, DC mode only) |
UINT32 |
RO |
0x00000384 (900dec) |
|
1C32:04 |
Sync modes supported |
Supported synchronization modes:
|
UINT16 |
RO |
0x0804 (2052dec) |
|
1C32:05 |
Minimum cycle time |
Minimum cycle time (in ns) |
UINT32 |
RO |
0x00001F40 (8000dec) |
|
1C32:06 |
Calc and copy time |
Minimum time between SYNC0 and SYNC1 event (in ns, DC mode only) |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C32:07 |
Minimum delay time |
|
UINT32 |
RO |
0x00000384 (900dec) |
|
1C32:08 |
Command |
The entries 0x1C32:03, 0x1C32:05, 0x1C32:06, 0x1C32:09, 0x1C33:03, 0x1C33:06, and 0x1C33:09 are updated with the maximum measured values. |
UINT16 |
RW |
0x0000 (0dec) |
|
1C32:09 |
Maximum delay time |
Time between SYNC1 event and output of the outputs (in ns, DC mode only) |
UINT32 |
RO |
0x00000384 (900dec) |
|
1C32:0B |
SM event missed counter |
Number of missed SM events in OPERATIONAL (DC mode only) |
UINT16 |
RO |
0x0000 (0dec) |
|
1C32:0C |
Cycle exceeded counter |
Number of occasions the cycle time was exceeded in OPERATIONAL (cycle was not completed in time or the next cycle began too early) |
UINT16 |
RO |
0x0000 (0dec) |
|
1C32:0D |
Shift too short counter |
Number of occasions that the interval between SYNC0 and SYNC1 event was too short (DC mode only) |
UINT16 |
RO |
0x0000 (0dec) |
|
1C32:20 |
Sync error |
The synchronization was not correct in the last cycle (outputs were output too late; DC mode only) |
BOOLEAN |
RO |
0x00 (0dec) |
Index 1C33 SM input parameter
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C33:0 |
SM input parameter |
Synchronization parameters for the inputs |
UINT8 |
RO |
0x20 (32dec) |
|
1C33:01 |
Sync mode |
Current synchronization mode:
|
UINT16 |
RW |
0x0000 (0dec) |
|
1C33:02 |
Cycle time |
as 0x1C32:02 |
UINT32 |
RW |
0x000C3500 (800000dec) |
|
1C33:03 |
Shift time |
Time between SYNC0 event and reading of the inputs (in ns, only DC mode) |
UINT32 |
RO |
0x00000384 (900dec) |
|
1C33:04 |
Sync modes supported |
Supported synchronization modes:
|
UINT16 |
RO |
0x0804 (2052dec) |
|
1C33:05 |
Minimum cycle time |
as 0x1C32:05 |
UINT32 |
RO |
0x00001F40 (8000dec) |
|
1C33:06 |
Calc and copy time |
Time between reading of the inputs and availability of the inputs for the master (in ns, only DC mode) |
UINT32 |
RO |
0x00000000 (0dec) |
|
1C33:07 |
Minimum delay time |
|
UINT32 |
RO |
0x00000384 (900dec) |
|
1C33:08 |
Command |
as 0x1C32:08 |
UINT16 |
RW |
0x0000 (0dec) |
|
1C33:09 |
Maximum delay time |
Time between SYNC1 event and reading of the inputs (in ns, only DC mode) |
UINT32 |
RO |
0x00000384 (900dec) |
|
1C33:0B |
SM event missed counter |
as 0x1C32:11 |
UINT16 |
RO |
0x0000 (0dec) |
|
1C33:0C |
Cycle exceeded counter |
as 0x1C32:12 |
UINT16 |
RO |
0x0000 (0dec) |
|
1C33:0D |
Shift too short counter |
as 0x1C32:13 |
UINT16 |
RO |
0x0000 (0dec) |
|
1C33:20 |
Sync error |
as 0x1C32:32 |
BOOLEAN |
RO |
0x00 (0dec) |
Index F000 Modular device profile
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F000:0 |
Modular device profile |
General information for the modular device profile |
UINT8 |
RO |
0x02 (2dec) |
|
F000:01 |
Module index distance |
Index spacing of the objects of the individual channels |
UINT16 |
RO |
0x0010 (16dec) |
|
F000:02 |
Maximum number of modules |
Number of channels |
UINT16 |
RO |
0x0010 (16dec) |
Index F008 Code word
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F008:0 |
Code word |
reserved |
UINT32 |
RW |
0x00000000 (0dec) |
Index F010 Module list
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
F010:0 |
Module list |
MDP Profile |
UINT8 |
RW |
0x10 (16dec) |
|
F010:01 |
SubIndex 001 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:02 |
SubIndex 002 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:03 |
SubIndex 003 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:04 |
SubIndex 004 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:05 |
SubIndex 005 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:06 |
SubIndex 006 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:07 |
SubIndex 007 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:08 |
SubIndex 008 |
|
UINT32 |
RW |
0x00000078 (120dec) |
|
F010:09 |
SubIndex 009 |
|
UINT32 |
RW |
0x00000079 (121dec) |
|
F010:0A |
SubIndex 010 |
|
UINT32 |
RW |
0x00000079 (121dec) |
|
F010:0B |
SubIndex 011 |
|
UINT32 |
RW |
0x00000079 (121dec) |
|
F010:0C |
SubIndex 012 |
|
UINT32 |
RW |
0x00000079 (121dec) |
|
F010:0D |
SubIndex 013 |
|
UINT32 |
RW |
0x00000079 (121dec) |
|
F010:0E |
SubIndex 014 |
|
UINT32 |
RW |
0x00000079 (121dec) |
|
F010:0F |
SubIndex 015 |
|
UINT32 |
RW |
0x00000079 (121dec) |
|
F010:10 |
SubIndex 016 |
|
UINT32 |
RW |
0x00000079 (121dec) |