Input data
Index 6000 FB inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
6000:0 | FB Inputs | Maximum subindex | UINT8 | RO | 0x11 (17dec) |
6000:0E | TxPDO State | TRUE: The position data are invalid | BOOLEAN | RO | 0x00 (0dec) |
6000:0F | Input cycle counter | Incremented with each process data cycle, switches to 0 after reaching the maximum value of 3 | BIT2 | RO | 0x00 (0dec) |
6000:11 | Position | Position | UINT32 | RO | 0x00000000 (0dec) |
Index 6001 FB Touch probe inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
6001:0 | FB Touch probe inputs | Maximum subindex | UINT8 | RO | 0x14 (20dec) |
6001:01 | TP1 Enable | Touch probe 1 enabled | BOOLEAN | RO | 0x00 (0dec) |
6001:02 | TP1 Pos value stored | Positive value of Touch probe 1 stored | BOOLEAN | RO | 0x00 (0dec) |
6001:03 | TP1 Neg value stored | Negative value of Touch probe 1 stored | BOOLEAN | RO | 0x00 (0dec) |
6001:08 | TP1 Input | Digital input Touch probe 1 | BOOLEAN | RO | 0x00 (0dec) |
6001:09 | TP2 Enable | Touch probe 2 enabled | BOOLEAN | RO | 0x00 (0dec) |
6001:0A | TP2 Pos value stored | Positive value of Touch probe 2 stored | BOOLEAN | RO | 0x00 (0dec) |
6001:0B | TP2 neg value stored | Negative value of Touch probe 2 stored | BOOLEAN | RO | 0x00 (0dec) |
6001:10 | TP2 Input | Digital input Touch probe 2 | BOOLEAN | RO | 0x00 (0dec) |
6001:11 | TP1 Pos position | Positive value of Touch probe 1 | UINT32 | RO | 0x00000000 (0dec) |
6001:12 | TP1 Neg position | Negative value of Touch probe 1 | UINT32 | RO | 0x00000000 (0dec) |
6001:13 | TP2 Pos position | Positive value of Touch probe 2 | UINT32 | RO | 0x00000000 (0dec) |
6001:14 | TP2 Neg position | Negative value of Touch probe 2 | UINT32 | RO | 0x00000000 (0dec) |
Index 6010 DRV Inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
6010:0 | DRV Inputs | Maximum subindex | UINT8 | RO | 0x13 (19dec) |
6010:01 | Statusword | Statusword | UINT16 | RO | 0x0000 (0dec) |
6010:03 | Modes of operation display | Modes of operation display. Permitted values: | UINT8 | RO | 0x00 (0dec) |
6010:06 | Following error actual value | Following error | INT32 | RO | 0x00000000 (0dec) |
6010:07 | Velocity actual value | Display of the current velocity value | INT32 | RO | 0x00000000 (0dec) |
6010:08 | Torque actual value | Display of current torque value | INT16 | RO | 0x0000 (0dec) |
6010:12 | Info data 1 | Synchronous information (selection via subindex 0x8010:39) | UINT16 | RO | 0x0000 (0dec) |
6010:13 | Info data 2 | Synchronous information (selection via subindex 0x8010:3A) | UINT16 | RO | 0x0000 (0dec) |
The following note relates to the DMC objects 0x6030, 0x7030, 0x8030 and 0x8031.
Data type INT64 for all positions in the travel distance control The data type INT64 is used for all positions in the travel distance control.
|
Index 6030 DMC inputs
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
6030:0 | DMC Inputs | Maximum subindex | UINT8 | RO | 0x3C (60dec) |
6030:02 | DMC_FeedbackStatus__Latch extern valid | An edge was detected on the external input and latched | BOOLEAN | RO | 0x00 (0dec) |
6030:03 | DMC_FeedbackStatus__Set counter done | The setting of the feedback position was successful. This bit remains present until "Set counter" is released again | BOOLEAN | RO | 0x00 (0dec) |
6030:0D | DMC_FeedbackStatus__Status of extern Latch | Status of the external latch input | BOOLEAN | RO | 0x00 (0dec) |
6030:11 | DMC_DriveStatus__Ready to enable | The drive hardware is ready for activation. | BOOLEAN | RO | 0x00 (0dec) |
6030:12 | DMC_DriveStatus__Ready | The drive hardware is activated. | BOOLEAN | RO | 0x00 (0dec) |
6030:13 | DMC_DriveStatus__Warning | A warning is pending in the drive. | BOOLEAN | RO | 0x00 (0dec) |
6030:14 | DMC_DriveStatus__Error | An error is pending in the drive. The "Ready to enable" bit and the "Ready" bit are set to FALSE. | BOOLEAN | RO | 0x00 (0dec) |
6030:15 | DMC_DriveStatus__Moving positive | The axis moves in positive direction. | BOOLEAN | RO | 0x00 (0dec) |
6030:16 | DMC_DriveStatus__Moving negative | The axis moves in negative direction | BOOLEAN | RO | 0x00 (0dec) |
6030:1C | DMC_DriveStatus__Digital Input 1 | Status of the first digital input | BOOLEAN | RO | 0x00 (0dec) |
6030:1D | DMC_DriveStatus__Digital Input 2 | Status of the second digital input | BOOLEAN | RO | 0x00 (0dec) |
6030:21 | DMC_PositioningStatus__Busy | The positioning task is running. | BOOLEAN | RO | 0x00 (0dec) |
6030:22 | DMC_PositioningStatus__In-Target | The axis is at the target position. | BOOLEAN | RO | 0x00 (0dec) |
6030:23 | DMC_PositoningStatus__Warning | Warning | BOOLEAN | RO | 0x00 (0dec) |
6030:24 | DMC_PositoningStatus__Error | error | BOOLEAN | RO | 0x00 (0dec) |
6030:25 | DMC_PositoningStatus__Calibrated | The axis is calibrated. | BOOLEAN | RO | 0x00 (0dec) |
6030:26 | DMC_PositioningStatus__Accelerate | The axis accelerates. | BOOLEAN | RO | 0x00 (0dec) |
6030:27 | DMC_PositioningStatus__Decelerate | The axis is decelerating. | BOOLEAN | RO | 0x00 (0dec) |
6030:28 | DMC_PositoningStatus__Ready to execute | The path control is ready to accept a command. This bit is FALSE if:
| BOOLEAN | RO | 0x00 (0dec) |
6030:31 | DMC__Set position | Current target position specified by the ramp generator in feedback increments | INT64 | RO | 0x0000000000000000 (0dec) |
6030:32 | DMC__Set velocity | Current velocity specified by the ramp generator in 10000ths of the rated motor speed | INT16 | RO | 0x0000 (0dec) |
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
6030:33 | DMC__Actual drive time | Time since the start of the motion command in ms. | UINT32 | RO | 0x00000000 (0dec) |
6030:34 | DMC__Actual position lag | Following error | INT64 | RO | 0x0000000000000000 (0dec) |
6030:35 | DMC__Actual velocity | Current velocity in 10000ths of the rated motor speed | INT16 | RO | 0x0000 (0dec) |
6030:36 | DMC__Actual position | Current position from the feedback (incl. possible offsets due to homing, ...) | INT64 | RO | 0x0000000000000000 (0dec) |
6030:37 | DMC__Error id | Error Id (identical to Diag History) | UINT32 | RO | 0x00000000 (0dec) |
6030:38 | DMC__Input cycle counter | Incremented with each process data cycle | UINT8 | RO | 0x00 (0dec) |
6030:3A | DMC__Latch value | Feedback position at latch time | INT64 | RO | 0x0000000000000000 (0dec) |
6030:3B | DMC__Cyclic info data 1 | Synchronous info data | INT16 | RO | 0x0000 (0dec) |
6030:3C | DMC__ Cyclic info data 2 | Synchronous info data | INT16 | RO | 0x0000 (0dec) |