Technical data

General

ED3361-0100

Number of channels | Total

1

Internal communication protocol

EtherCAT

Minimum cycle time

100 µs

Analog input
measuring bridge (strain gauge)

ED3361-0100

Number of channels

1

Sensor type

Strain gauges (DMS), load cells

Connection technology

4-wire, 6-wire

Resolution | Technical

24 bit

Resolution | Process data

18.34... nV/V

Display | Process data

REAL32, INT16, INT32

ADC conversion method

Delta-Sigma

Type of conversion

simultaneous

Conversion time

min. 100 µs

Conversion rate

max. 10 ksps

Signal range |UBridge

± 4 V DC

Signal range |UBridge, end value (FSV)

4 V DC

Signal range | USense

± 12 V DC

Signal range |USense, end value (FSV)

12 V DC

Internal resistance/impedance | UBridge

min. 5 MΩ

Internal resistance/impedance |USense

min. 5 MΩ

Ground reference

differential

Measuring procedure

ratiometric

Input filter cut-off frequency

10 kHz

Dielectric strength

max. 30 V

Accuracy/uncertainty | From FSV (23 °C)

< ±0.05 % for the ratio of UBridge/USense

Accuracy/uncertainty | From FSV
(largest short-term deviation during an electrical disturbance test)

< ±1 %

Temperature coefficient

typ. < 15 ppm/K

Channel crosstalk

typ. < -90 dB

Sensor power supply | Output voltage

5 V DC/10 V DC

Output current | sensor power supply

max. 100 mA

Wire break detection

yes (only forUSense)

XFC

ED3361-0100

Distributed Clocks

no

Timestamp

no

Oversampling

no

Supply and electrical isolation

ED3361-0100

Electronics | supply voltage

via E-bus

E-bus | current consumption

typ. 100 mA

Power contacts | Input voltage

24 V DC (-15 %/+20 %)

Power contacts | Current carrying capacity

max. 10 A

Power contacts | Current consumption

load-dependent on the supply of the strain gauge used

Power contacts | Output voltage

corresponds to Power contacts | Input voltage

Electrical isolation | Channel/channel

no

Electrical isolation | Channel/bus

functional, 707 VDC type test

Environmental conditions

ED3361-0100

Operating temperature

-25 … +55 °C

Storage temperature

-40…+85 °C

Relative humidity

95 %, no condensation

Installation position

variable

Standards and approvals

ED3361-0100

Vibration resistance

conforms to EN 60068-2-6

Shock resistance

conforms to EN 60068-2-27

EMC immunity

conforms to EN 61000-6-2

EMC emission

conforms to EN 61000-6-4

Markings*)

CE

Approvals*)

-

*) Real applicable approvals/markings see name plate on the side (product labeling)

Housing data

ED-12-16pin

Weight

approx. 60 g

Protection rating

IP20

Material

polycarbonate

Dimensions | Width (single)

15 mm

Dimensions | Width (stacked)

12 mm

Dimensions | Height

100 mm

Dimensions | Depth

65 mm

Mounting | Terminal/back wall

35-mm-mounting-rail (EN 60715)

Mounting | Terminal/terminal

double groove-tongue connection

pluggable wiring level

no

Connection technology

push-in

Connection cross-section | Single‑wire, solid

0.08…1.5 mm²

Connection cross-section | Fine wire, stranded wire

0.25…1.5 mm²

Connection cross-section | ferrule

0.14…0.75 mm²

Connection cross-section AWG | Single‑wire, solid

AWG28…16

Connection cross-section AWG | fine wire, stranded wire

AWG22…16

Connection cross section AWG | Wire end ferrule

AWG26…19

Strip length

8 … 9 mm

Power contact | "+" (left)

yes

Power contact | "+" (right)

yes

Power contact | "-" (left)

yes

Power contact | "-" (right)

yes

Power contact | "⏚" (left)

no

Power contact | "⏚" (right)

no

Slide-in lock for power contact "⏚"

yes