Product overview
The Beckhoff Panel generation with industrial multi-touch display is designed for installation on the mounting arm. The devices offer suitable solutions for a variety of applications.
The control panel has the following features:
- 21.5-inch landscape mode, 1920 x 1080 (16:9)
- Multi-finger touch screen (PCT): e.g. for 10-finger touch
- Aluminum housing with glass front, IP65 all-round; the housing surface is electrically insulating
- Installation on an optional support arm system
Push-button extension
The control panel includes an angled push-button extension in a special CNC function design for CNC applications.
You can label the push buttons using the push-in strips. To access the push-in strips, you must open the push-button extension as follows:
- 1. Loosen and remove the eight M3x8 screws on the bottom of the push-button extension (section A). Make sure that the cover is secured against falling down.
- 2. Remove the cover (section B).
- You now have access to the push-in strips.
- 3. Place the cover back on the underside of the push-button extension. Make sure that it is secured against falling down.
- 4. Insert and tighten the eight M3x8 screws.
- You have closed the push-button extension again.
Below you will find an overview of the arrangement of the operating elements on the push-button extension.

Position push buttons/switches | Type | Color | Contact via USB | Directly wired contact 2 | Light source |
|---|---|---|---|---|---|
S1 | Emergency stop switch | - | Normally open contact | 2 normally closed contacts | - |
S2 | Illuminated push button | green | Normally open contact | Normally open contact | LED, white |
S3 | Illuminated push button | red | Normally open contact | Normally closed contact | LED, white |
S4 | Illuminated push button | clear | Normally open contact | Normally closed contact | LED, white |
S5 | Gray code | - | 5 normally open contacts | - | - |
S6 | Gray code | - | 5 normally open contacts | - | - |
S7 | Illuminated push button | green | Normally open contact | - | LED, white |
S8 | Illuminated push button | red | Normally open contact | - | LED, white |
S9 | Illuminated push button | clear | Normally open contact | - | LED, white |
S10 | Illuminated push button | clear | Normally open contact | - | LED, white |
S11 | Illuminated push button | clear | Normally open contact | - | LED, white |
S12 | Illuminated push button | clear | Normally open contact | - | LED, white |
S13 | Illuminated push button | clear | Normally open contact | - | LED, white |
S14 | Illuminated push button | clear | Normally open contact | - | LED, white |
S15 | Illuminated push button | clear | Normally open contact | - | LED, white |
S16 | Illuminated push button | clear | Normally open contact | - | LED, white |
S17 | Illuminated push button | clear | Normally open contact | - | LED, white |
S18 | Illuminated push button | clear | Normally open contact | - | LED, white |
S19-S63 | Membrane keys | - | Normally open contact | - | LED, green |