Product overview
The C6670-0020 is a powerful industrial server for control cabinet installation. The device is suitable for various applications and requirements. You can use the industrial server for the following applications, among others:
- various automation and visualization tasks
- a wide range of IoT tasks with data preprocessing
- complicated HMI applications
- extensive axis controllers
- short cycle times
- high-volume data handling
The device is equipped with a server motherboard for two Intel® Xeon® CPUs and an NVMeTM SSD, a 100-240 V AC power supply, a graphics card and two hard drive caddies for hard disks. To further configure the device, you must select a CPU, main memory and SSD from the following options ex factory. It is essential to select from these options:
Order number | Performance | Link to option |
|---|---|---|
C9900-C593 | 2 processors, 2.4 GHz, 12 cores per processor | https://www.beckhoff.com/c6670-0020 Select the “Options” tab at the bottom of the website. |
C9900-C594 | 2 processors, 2.0 GHz, 16 cores per processor | |
C9900-C595 | 2 processors, 2.8 GHz, 16 cores per processor | |
C9900-C596 | 2 processors, 2.2 GHz, 24 cores per processor | |
C9900-C597 | 2 processors, 2.2 GHz, 28 cores per processor | |
C9900-C598 | 2 processors, 2.1 GHz, 32 cores per processor |
Order number | Storage capacity | Link to option |
|---|---|---|
C9900-R291 | 128 GB | https://www.beckhoff.com/c6670-0020 Select the “Options” tab at the bottom of the website. |
C9900-R292 | 256 GB | |
C9900-R293 | 384 GB | |
C9900-R294 | 512 GB | |
C9900-R295 | 768 GB | |
C9900-R296 | 1024 GB |
Order number | Storage capacity | Link to option |
|---|---|---|
C9900-H823 | 160 GB | https://www.beckhoff.com/c6670-0020 Select the “Options” tab at the bottom of the website. |
C9900-H824 | 320 GB | |
C9900-H825 | 640 GB |
In addition to the necessary configuration ex factory, further options are available at a later date, which you can select as required. The selection of these options is not necessarily required:
Order number | Description | Link to option |
|---|---|---|
C9900-H814 | 160 GB NVMeTM SSD, PCIe® x4 plug-in card | https://www.beckhoff.com/c6670-0020 Select the “Options” tab at the bottom of the website. |
C9900-H815 | 320 GB NVMeTM SSD, PCIe® x4 plug-in card | |
C9900-H816 | 640 GB NVMeTM SSD, PCIe® x4 plug-in card | |
C9900-H152 | 3½-inch hard disk 1 TB | |
C9900-H203 | 3½-inch hard disk 2 TB | |
C9900-H204 | 3½-inch hard disk 4 TB | |
C9900-D118 | Multi DVD drive Slimline |
The following fieldbus cards are not compatible with the industrial server:
- FC1121
- FC312x
- FC512x
- FC532x