Optional interfaces
You have the option of adding optional interfaces to your device. On the one hand, you can do this using PCIe® modules. This requires the device to be equipped with two PCIe® module slots (C9900-B503). The depth of the inner housing cover increases by 27 mm due to the module slots. On the other hand, you can order additional interfaces ex factory, which are led out in the connection section of the device.
To install a PCIe® module in your device, you must first remove the panels. To do this, remove the two M3 screws from the panels.
You can order the following PCIe® modules for your device:
Order number | Description | Link to option |
---|---|---|
FC9062 | Gigabit Ethernet PCIe® module | https://www.beckhoff.com/c65xx Select a PC, then the product variant, and then the “Options” tab at the bottom of the website. |
C9900-E301 | RS232 PCIe® module | |
C9900-E309 | RS485 PCIe® module | |
C9900-E310 | RS422 PCIe® module | |
C9900-E277 | USB 3.0 PCIe® module |
The additional interfaces for the connection section vary depending on the device generation. You can order the following interfaces ex factory for the connection section:
Device generation | Order number | Description | Link to option |
---|---|---|---|
C6525-0060 | C9900-E294 | DisplayPort | https://www.beckhoff.com/c65xx Select a PC, then the product variant, and then the “Options” tab at the bottom of the website. |
C9900-E308 | Serial interface RS232 | ||
C9900-E234 | 2 USB ports | ||
C9900-E292 | DisplayPort | ||
C9900-E237 | DVI socket | ||
C9900-E238 | DVI socket | ||
FC9071-0000 | Gigabit Ethernet PC network card | ||
C6525-0070/-0080 | C9900-E294 | DisplayPort | https://www.beckhoff.com/c65xx Select a PC, then the product variant, and then the “Options” tab at the bottom of the website. |
C9900-E234 | 2 USB ports | ||
C9900-E292 | DisplayPort | ||
C9900-E237 | DVI socket | ||
C9900-E238 | DVI socket | ||
FC9071-0000 | Gigabit Ethernet PC network card | ||
C9900-E159 | Serial interface RS232 | ||
C9900-E188 | Serial interface RS485 | ||
C9900-E189 | Serial interface RS422 |
You can only order one serial interface as an option.
- PCIe® module FC9062 with 2 Gigabit Ethernet ports
- PCIe® module C9900-E301 with 2 serial interfaces RS232
- PCIe® module C9900-E309 with 2 serial interfaces RS485
- PCIe® module C9900-E310 with 2 serial interfaces RS422
- PCIe® module C9900-E277 with 2 USB 3.0 interfaces
- DisplayPort
- USB
- DVI
- Ethernet RJ45
- Serial interface RS232
- Serial interface RS485
- Serial interface RS422