Ethernet RJ45
The C6015 has two Gigabit LAN ports (X102, X103). The 100Base-T, 1000Base-T, and 2500Base-T Ethernet standards enable the connection of corresponding network components and data rates of 100/1000/2500 Mbit/s. The required speed is selected automatically.
The RJ45 connection technology with twisted-pair cables is used. The maximum length of the cable connection is 100 m.
The controllers are used as follows, based on the device generation:
Device generation | Controller | Mbit/s |
|---|---|---|
C6015-0010 | Intel® i210 for LAN1 and LAN2 | 100/1000 |
C6015-0020 | Intel® i210 for LAN1 and LAN2 | 100/1000 |
C6015-0030 | Intel® i226 for LAN1 and LAN2 | 100/1000/2500 |
The Ethernet ports i210/i226 connected via PCIe® are suitable for cycle times <= 1 ms and for distributed clock applications with EtherCAT.
Pin | Signal | Description |
|---|---|---|
1 | T2 + | Pair 2 |
2 | T2 - | |
3 | T3 + | Pair 3 |
4 | T1 + | Pair 1 |
5 | T1 - | |
6 | T3 - | Pair 3 |
7 | T4 + | Pair 4 |
8 | T4 - |
The LEDs of the LAN interfaces indicate the activity and the data transmission rate (Mbit/s). The LED (LINK/ACT) highlighted completely green in the figure indicates whether the interface is connected to a network. If this is the case, the LED lights up green. The LED flashes green when data transmission is in progress on the interface.
The green/orange LED (SPEED) shown in the figure indicates the data transmission rate.
The device generations differ in terms of the possible data transmission rate. The following tables show what the LEDs mean with regard to the potential data transmission rate.
Mbit/s | LED |
|---|---|
100 | Lights up orange |
1000 | Lights up green |
Mbit/s | LED |
|---|---|
100 | Off |
1000 | Lights up orange |
2500 | Lights up green |