ZS4800-2043 / AX8128 connector plug and AX85xx combined modules

ZS4800-2043 / AX8128 connector plug and AX85xx combined modules 1:

Terminal point

Connection

PE

Protective conductor

W

Motor connection W

V

Motor connection V

U

Motor connection U

Wire cross-section

Maximum 16 mm²
AWG 6

Mounting

Push in

Notice

Connection of third-party motors

A temperature sensor with double isolation or reinforced isolation is required for the operation of a third-party motor with a temperature sensor on the AX8000.

The AX8000 multi-axis servo system and further components can be damaged if this is ignored.

ZS4800-2043 / AX8128 connector plug and AX85xx combined modules 2:

No connection of OCT, temperature sensor and holding brake

The ZS4500-2014 connector is required to connect the OCT, temperature sensor and holding brake.