Wide voltage range of the power supply

Due to the wide voltage range of the power supply modules, the AX8000 multi-axis servo system can be operated worldwide on different voltage systems.

All networks with a grounded center point are permitted; TT / TN.

Data are given below for the wide voltage range of the power supply modules for the different supply networks:

Single-phase supply networks

Three-phase supply networks

1 x 100-10% V AC…1 x 240+10% V AC

3 x 200-10% V AC…3 x 480+8% V AC

Wide voltage range of the power supply 1:

Supply networks

Further information on all supply networks in the chapter:

→ Electrical installation, supply networks

Wide voltage range of the power supply 2:

Country-specific examples

The following table contains examples of different network systems in various countries:

Country

Single-phase
Supply networks

Three-phase
Supply networks

Japan

1 x 100 V AC

3 x 200 V AC

North America

1 x 115 V AC

3 x 480 V AC

Europe

1 x 230 V AC

3 x 400 V AC