Dual Use

According to the published EU Regulation No. 2021/821, commercially available frequency inverters are categorized as dual-use items. This means that the Beckhoff AMP8000 multi-axis servo system belongs to the category of goods that could be included in a dual-use listing.

The goods list, Annex 1 of the Dual Use Regulation No. 2021/821, has been amended accordingly:

Dual-use listing information

The type key of the AX8000 multi-axis servo system determines whether export control in accordance with a dual-use listing is required. If the type key for the axis modules of the Beckhoff AX8000 multi-axis servo system contains a "g", export control in accordance with the dual-use listing is required.

AX8xyz–abcd–efgh

Ordering information

Description

g =

dual use

0

product not subject to authorization as the rotating field frequency is limited to 599 Hz during production.

8

product subject to export authorization, if applicable

AX8xxx–xxxx–xx0x

In the standard design and according to the current state of production, the AX8000 multi-axis servo system is delivered with a maximum rotary field frequency of 599 Hz.

Ordering information

Description

AX8108-xxxx-xx0x

Single-axis module, 8 A, standard

AX8118-xxxx-xx0x

Single-axis module, 18 A, standard

AX8128-xxxx-xx0x

Single-axis module, 28 A, standard

AX8206-xxxx-xx0x

Dual-axis module, 2 x 6 A, standard

AX8525-xxxx-xx0x

Combined power supply and axis module, 25 A, standard

AX8540-xxxx-xx0x

Combined power supply and axis module, 40 A, standard

AX8xxx–xxxx–xx8x

Under certain conditions, the modules of the AX8000 multi-axis servo system are suitable for operating high-frequency spindles with a maximum speed of up to 96,000 rpm. In this version, the rotary field frequency is ≥ 600 Hz and the device is subject to export control.

Ordering information

Description

AX8108-xxxx-xx8x

Single-axis module, 8 A, dual use

AX8118-xxxx-xx8x

Single-axis module, 18 A, dual use

AX8128-xxxx-xx8x

Single-axis module, 28 A, dual use

AX8206-xxxx-xx8x

Dual-axis module, 2 x 6 A, dual use

AX8525-xxxx-xx8x

Combined power supply and axis module, 25 A, dual use

AX8540-xxxx-xx8x

Combined power supply and axis module, 40 A, dual use