AX85xx type key

AX 85 yz - a b c d -  e f g h

Explanation

AX

Product area

  • Servo drives

8

Series

  • AX8000

5

Combined power supply and axis module

yz

Nominal DC link output current

  • 25 = up to 50 A DC
  • 40 = ≥ 35 A DC, depending on the connected rated motor current

Rated channel current

  • 25 = 1 x 25 A AC
  • 40 = 1 x 40 A AC

a

Supply

  • 0 = 200…480 V AC

DC link voltage

  • 0 = 0…848 V DC

b

Safety function

  • 0 = No safety function
  • 1 = Safety functions TwinSAFE, STO/SS1
  • 2 = Safety functions TwinSAFE, Safe Motion (17 safety functions)

All information on the safety functions integrated in the drive can be found in the chapter Ordering options.

c

Hardware features

  • 0 = OCT, EnDat® 3
  • 1 = not available
  • 2 = EnDat® 2.2/22, BiSS® C, TTL (DIFF RS422), SinCos 1 Vpp

d

Version

  • 0 = Standard

e

Version

  • 0 = Standard

f

Version

  • 0 = Standard

g

Dual Use

  • 0 = maximum rotating field frequency ≤ 599 Hz
  • 8 = rotating field frequency ≥ 600 Hz

Further information can be found in the Dual Use chapter.

h

Version

  • 0 = Standard