Error codes

Error code

Error description

F152

Channel Errors

If only this error is displayed, it is probably a two-channel device and the error cause is located in the other channel. Otherwise, observe the other error messages!

F702

Superordinate message. Please observe the other error messages!

F70E

Superordinate message. Please observe the other error messages!

F707

No feedback voltage

  • The power supply is not correctly connected.
  • The sense line is not correctly connected.
  • No sense connection exists.

FA01

Initialization error

  • Incorrect setting in parameter P-0-0150.
  • Wiring error

FA49

Feedback process channel error (1Vss)

The amplitude of the analog signal is too small -> check the connection.

F4A5

SoE Communication Parameter Error (see section “Error F4A5”)

Error codes 1:

Consequential error!

Please contact the Beckhoff applications department if the servo drive displays consequential errors that are not described in this section!