P-x-0061 Motor temperature sensor type

This parameter configures the temperature sensor type and the connector of the AX5000.

Attributes

Name

Value

Datatype

udec

Data length in bit

16

Decimal point

0

Min. Value

0

Default

4

Max. Value

7; from Rev. 210: 8

Unit

-

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

changed from Rev. 210

Value

Description

0

Motor cable: temperature switch

1

Motor cable: KTY 83-110

2

Resolver cable: temperature switch

3

Motor cable: KTY 84-130

4

No motor temperature switch or sensor (off)

5

Via feedback process data: KTY 83-110

6

Via feedback process data: KTY 84-130

7

Via feedback process data: characteristic table

8

Motor cable: characteristic table (from Rev. 210)


P-x-0061 Motor temperature sensor type 1:

Included in the “Parameter Set Switching” function group!

This IDN exists as P-0-0061 - P-7-0061.

P-x-0061 Motor temperature sensor type 2:

For further information please look into the involved IDN:

P-0-0076