Ballast calculation for single-axis drives

This documentation refers to single-axis drives. Further calculations are required for multi-axis drives and coupled axes.

Reaction of a servomotor during operation:

The feedback causes an increase in the DC link voltage, which is limited by the maximum permissible DC link voltage of the servo drive (by a brake resistor). This limitation serves to protect the device. The excess energy is converted into heat in the brake resistor.

The power that is fed back can be calculated from the available kinetic energy. The result is offset pro rata against the total cycle time. The additional energy (Ec) is not taken into account. It serves as a reserve.

Example:

Default values

Ec[Ws] = 0.5 x CDC link (850 V² - 600 V²)

Special case with an EL72xx servo terminal:

Formula

Ec [Ws] = 0.5 x CDC link (55 V² - 48 V²)

*1: Below this threshold, the energy is stored in the DC link capacitors.

Additional storable energy of an AX5000 servo drive at 400 VAC (EL72xx at 48 VDC) supply voltage

Servo drives

DC link capacitance [µF]

Storable energy [Ws]

AX5101 – AX5106

235

42

AX5112

470

85

AX5118

940

170

AX5125

1175

212

AX5140

1485

270

AX5201 – AX5203

235

42

AX5206

470

85

AX5160 – AX5172

900

163

AX5190

1060

192

AX5191

2120

384

AX5192

3180

576

AX5193

4240

768

AX5021

705

128

Servo terminal

 

 

EL7201

53

0.019

Ballast calculation for single-axis drives 1:

Calculation of the load moment of inertia:

For an exact determination of the inertia reduced to the motor shaft, please use the
Beckhoff TE5910 | TwinCAT3 Motion Designer.