SETVCT

ASCII - Command

SETVCT

 

 

Syntax Transmit

SETVCT [Data]

 

Syntax Receive

SETVCT <Data>

Available in

 

Type

Variable rw

MMI

No

ASCII Format

Integer16

CANBus Object Number

3635 (hex)

DIM

-

PROFIBUS PNU

1909 (dec) IND = 0000xxxx (bin)

Range

0 .. 7

DPR

309 (dec)

Default

0

 

Opmode

0, 1

Data Type Bus/DPR

Integer16

Drive State

-

Weightning

 

Start Firmware

2.42

 

Configuration

No

Revision

1.3

Function Group

Digital I/O

EEPROM

No

Short Description

Select a VCT Entry

Description

The SETVCT command can be used to activate an entry in the VC table (velocity setpoint / current limit).

The VC table contains 8 velocity/current pairs (VCT entries).

When a VCT entry is activated, the velocity value that has been entered is taken as a digital velocity setpoint (only possible with OPMODE=0). The current value from the VCT entry is taken as the current limit.

With analog velocity setpoint provision (OPMODE=1) the velocity setpoint is ignored, but the current value is still used as the current limit.

If the SETVCT command is entered without additional parameters, the number of the presently active VCT entry is shown.

See also description of the VCTAB command.