ROFFS2
ASCII - Command  | ROFFS2  | 
  | 
  | |
Syntax Transmit  | ROFFS2 [Data]  | 
  | 
  | |
Syntax Receive  | ROFFS2 <Data>  | Available in  | 
  | |
Type  | Variable rw  | MMI  | No  | |
ASCII Format  | Integer32  | CANBus Object Number  | 3656 (hex)  | |
DIM  | PUNIT  | PROFIBUS PNU  | 1942 (dec) IND = 0000xxxx (bin)  | |
Range  | long int  | DPR  | 342 (dec)  | |
Default  | 0  | 
  | ||
Opmode  | 8  | Data Type Bus/DPR  | Integer32  | |
Drive State  | -  | Weightning  | 
  | |
Start Firmware  | 3.20  | 
  | ||
Configuration  | No  | Revision  | 1.3  | |
Function Group  | Gearing  | EEPROM  | Yes  | |
Short Description  | Position offset for "absolute Gearing"  | |||
Description
This parameter gives an offset to the absolute SSI-position of the master, read by the slave. This parameter is only used while starting the reference move NREF=8 (move to absolute position). Starting the reference move, the absolute SSI position (GEARMODE=7) is read by the slave using the resolution PGEARI / PGEARO. The ROFFS2 offset is added then and move to this target position is started.