PTBASE

ASCII - Command

PTBASE

 

 

Syntax Transmit

PTBASE [Data]

 

Syntax Receive

PTBASE <Data>

Available in

 

Type

Variable rw

MMI

No

ASCII Format

Integer8

CANBus Object Number

35D5 (hex)

DIM

-

PROFIBUS PNU

1813 (dec) IND = 0000xxxx (bin)

Range

1 .. 127

DPR

213 (dec)

Default

4 (1 msec)

 

Opmode

All

Data Type Bus/DPR

Integer8

Drive State

 

Weightning

 

Start Firmware

1.30

 

Configuration

No

Revision

1.6

Function Group

Position Controller

EEPROM

Yes

Short Description

Time base for the external trajectory

Description

The PTBASE parameter is used to define the interpolation time for the external trajectory (OPMODE=5). The time is set in 250 microsecond steps, and defined the time period in which the drive should reach the next position setpoint. Since the internal position control loop works in 250 microsecond steps, an interpolation of the given position setpoint (external trajectory) is also given in 250 microsecond steps.