OS2

ASCII - Command

OS2

 

 

Syntax Transmit

OS2 [Data]

 

Syntax Receive

OS2 <Data>

Available in

 

Type

Variable rw

MMI

No

ASCII Format

Integer8

CANBus Object Number

36C8 (hex)

DIM

-

PROFIBUS PNU

1656 (dec) IND = 0001xxxx (bin)

Range

0, 1

DPR

456 (dec)

Default

-

 

Opmode

All

Data Type Bus/DPR

Integer8

Drive State

-

Weightning

 

Start Firmware

5.41

 

Configuration

No

Revision

1.9

Function Group

Digital I/O

EEPROM

No

Short Description

Set/Reset of "Posreg2" of the I/O Option Card

Description

The I/O option card has 5 output pins which are normally used to signal on position registers SWE0-4.

OS2 sets the digital output "PosReg2" (terminal 7 of X11B) of the I/O option card.

Set SWCNFG Bit 4 to "0" to disable the appropriate register (SWE2) to reassign the output for use in general purpose mode.

This command allows using the output for general purposes through standard communication channels or through motion tasking.