ACTIVE

ASCII - Command

ACTIVE

 

 

Syntax Transmit

ACTIVE

 

Syntax Receive

ACTIVE <Data>

Available in

 

Type

Variable ro

MMI

Yes

ASCII Format

Integer8

CANBus Object Number

3504 (hex)

DIM

-

PROFIBUS PNU

1604 (dec) IND = 0000xxxx (bin)

Range

0, 1

DPR

4 (dec)

Default

-

 

Opmode

All

Data Type Bus/DPR

Integer8

Drive State

-

Weightning

 

Start Firmware

1.20

 

Configuration

No

Revision

1.3

Function Group

Drive Status

EEPROM

No

Short Description

Output stage active/inhibited

Description

The ACTIVE command returns the present status of the output stage.

The following conditions must be met to enable the output stage, depending on the controller configuration:

  1. Standard configuration (no active MainsBTB function)
  2. With active MainsBTB function (O1MODE or O2MODE=3)